Voltage transducer for traction DV 4200/SP4
  • Voltage transducer for traction DV 4200/SP4

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

Voltage transducer for traction DV 4200/SP4

Measures DC, AC, Pulse voltage with galvanic insulation between primary and secondary circuit.

Characteristics
• double direction, insulated voltage measurement up to 6kV
• Current input signal
• Connection of primary and secondary circuits with M5 screw

Advantages:
• Low current consumption
• Compact construction
• Excellent accuracy
• response time: 60µs
• Small temperature offset
• High resistance for external noise

Application
• Traction
• One and three phase inverters
• Driver inverters
• High power drives
• Energy measurement on the traction vehicle

Trakcyjny przetwornik napięciowy DV 4200/SP4
 

Electrical Data

Primary nominal RMS voltage VPN 4200 V
Primary voltage, measuring range VPM ±6000 V
Measuring resistance RM 0..140 Ω
Secondary nominal RMS current ISN 50 mA
Secondary current IS ±71.4 mA
Supply voltage ±UC ±24 Vdc
Current consumption IC (20 + IS) mA
Overall accuracy XG ±0.3% of VPN (@25°C, 100% tested in production)
Linearity error EL ±0.1% of VPM
Frequency bandwidth BW  0..12 kHz
RMS voltage for AC insulation test (50 Hz, 1 min) Ud 18.5 kV (100% tested in production)
Ambient operating temperature TA -40..+85 °C
Mass m 620 g
Norms: EN50155: 2007
EN50121-3-2 : 2006
EN50124-1 : 2001


Dimensions [mm]: DV 4200/SP4
Trakcyjny przetwornik napięciowy DV 4200/SP4

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Measures DC, AC, Pulse voltage with galvanic insulation between primary and secondary circuit.

Characteristics
• double direction, insulated voltage measurement up to 6kV
• Current input signal
• Connection of primary and secondary circuits with M5 screw

Advantages:
• Low current consumption
• Compact construction
• Excellent accuracy
• response time: 60µs
• Small temperature offset
• High resistance for external noise

Application
• Traction
• One and three phase inverters
• Driver inverters
• High power drives
• Energy measurement on the traction vehicle

Trakcyjny przetwornik napięciowy DV 4200/SP4
 

Electrical Data

Primary nominal RMS voltage VPN 4200 V
Primary voltage, measuring range VPM ±6000 V
Measuring resistance RM 0..140 Ω
Secondary nominal RMS current ISN 50 mA
Secondary current IS ±71.4 mA
Supply voltage ±UC ±24 Vdc
Current consumption IC (20 + IS) mA
Overall accuracy XG ±0.3% of VPN (@25°C, 100% tested in production)
Linearity error EL ±0.1% of VPM
Frequency bandwidth BW  0..12 kHz
RMS voltage for AC insulation test (50 Hz, 1 min) Ud 18.5 kV (100% tested in production)
Ambient operating temperature TA -40..+85 °C
Mass m 620 g
Norms: EN50155: 2007
EN50121-3-2 : 2006
EN50124-1 : 2001


Dimensions [mm]: DV 4200/SP4
Trakcyjny przetwornik napięciowy DV 4200/SP4