Sistemi za meki sart i reverziblni kontaktori

Our offer includes: soft starts, MCI soft starts - soft starts and stops systems, reversible relays type RCI and TCI - starting torque limiters – economic soft starts.

What is a contactor?

The contactor is a switch whose operating contacts are...

Our offer includes: soft starts, MCI soft starts - soft starts and stops systems, reversible relays type RCI and TCI...

Опширније
Прикажи филтере
Сакриј филтереФилтрацијаПрикажи филтере X
Manufacturers
more... less
Димензије
more... less
Напетост
more... less
Електрична енергија
more... less
Снага
more... less
Контакти
more... less
In stock
more... less
Filter
Информације close
Products that are marked "On Order" in the "Available Quantity" column are usually not in stock. Such products are available for purchase, however, due to their limited customer base, they usually have higher minimum quantities. DACPOL offers products that are not in stock for the following reasons: DACPOL currently has a large number of electronic components in stock and adds new products every day, however, tens of thousands of additional components and their various variants are available from our suppliers. Even though it is unreasonable to have all these products in stock due to the limited sales, we believe that it is in the best interest of our customers to make them available. Our goal is to inform customers about the maximum number of products available and enable them to make decisions based on specifications, prices, availability, required minimums and our technical advice. Please note that selecting the "In Stock" checkbox may limit the display to only products available for delivery straight from the shelf.
ПДФ Слика
Произвођач
Назив производа
Погледајте производ Не. Произвођач
Количина доступна
Димензије
Напетост
Електрична енергија
Снага
Контакти
picture_as_pdf Reverzibilni releji - tip RCI Danfoss Reverzibilni releji - tip RCI ВИДИ ГА -- On Order -- -- -- -- --
picture_as_pdf MCI soft start - soft start i zaustavljanje sustava Danfoss MCI soft start - soft start i zaustavljanje sustava ВИДИ ГА -- On Order -- -- -- -- --
picture_as_pdf Mekani pokreti Danfoss Mekani pokreti ВИДИ ГА -- On Order -- -- -- -- --
picture_as_pdf 037N0090 MCI-50 400-480VAC 11/25kW*Ust24-480VACDC Danfoss 037Н0090 МЦИ-50 400-480ВАЦ 11 / 25КВ * УСТ24-480ВАЦДЦ ВИДИ ГА 037N0090 On Order 180 380 - 480 V 35 (50) A 22 / 30 kW I-O, bypass
picture_as_pdf 037N0074 MCI-3 380-480VAC 1,5kW Ust 24-480VAC/DC Danfoss 037Н0074 МЦИ-3 380-480ВАЦ 1.5КВ 2-480ВАЦ / ДЦ ВИДИ ГА 037N0074 On Order 22,5 mm 380 - 415 V 3:00 AM 1,5 / 2 kW --
picture_as_pdf 037N0040 MCI-25 380-480VAC 11kW Ust 24-480VAC/DC Danfoss 037Н0040 МЦИ-25 380-480ВАЦ 11КВ 2-480ВАЦ / ДЦ ВИДИ ГА 037N0040 On Order 90 mm 380 - 480 V 25 A 11 / 15 kW --
picture_as_pdf 037N0039 MCI-15 380-480VAC 7,5kW 24-480VAC/DC Danfoss 037Н0039 МЦИ-15 380-480ВАЦ 7,5КВ 24-480ВАЦ / ДЦ ВИДИ ГА 037N0039 On Order 45 mm -- 15 A 7,5 kW --
picture_as_pdf 037N0070 MCI-30 380-480VAC 15kW* 24-480VAC/DC Danfoss 037Н0070 МЦИ-30 380-480ВАЦ 15кВ * 24-480ВАЦ / ДЦ ВИДИ ГА 037N0070 On Order 90 mm 380 - 480 V 25 (30) A 15 kW I-O, bypass
Резултати по страни:

Our offer includes: soft starts, MCI soft starts - soft starts and stops systems, reversible relays type RCI and TCI - starting torque limiters – economic soft starts.

What is a contactor?

The contactor is a switch whose operating contacts are closed by means of an electromagnet and kept in this state until the coil voltage is high enough. After breaking the circuit of the electromagnet coil, the armature falls (under the influence of the spring) and the working contacts open.

MCI soft starts 

They are perfect solutions for applications where there are many  soft start cycles. They can be used with pumps and ventilators, feeders, transporters.  Because of set up start torque and unique function (kick-start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start-ups and stops, which make production lines more reliable. Also start up currents' reduction lowers voltage drops on light mains.