Spannungswandler der DVL-Serie
  • Spannungswandler der DVL-Serie

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: LEM

Spannungswandler der DVL-Serie

Voltage transducers for Industrial and Traction - for small and medium voltage measurements

Main characteristics:

  • Compact design
  • A unique design to cover all measuring ranges
  • Voltage measurement from 50 to 2000 VRMS
  • High level of insulation test voltage: 8.5 KVRMS / 50 Hz / 1 min
  • High level of RMS voltage (2.7 kV) for partial discharges extinction @10 pC
  • Excellent overall accuracy:
    • +/- 0.4% of Vpn at + 25°C
    • +/- 1% of Vpn over the operating temperature range
  • High bandwidth (short response time): 14 KHz (-3 dB)

Features:

  • DC, AC and pulse voltage measurements with galvanic isolation
  • Power supply: +/- 13,5 ...26,4 V
  • Operating temperature range: -40°C to +85°C
  • Flexibility with modular connections for primary and secondary sides (connectors, shielded cables, terminals ...)
  • Current output as +/- 50 mA or current loop 4 to 20 mA

Standard compliance:

  • EN50155:2007 for traction applications such as:
    • Main and auxiliary converters
    • Circuit breaker
    • Substations
    • Battery chargers
    • Propulsion and braking chopper
    • but also industrial applications
  • European Directive EMC 2004 / 108 / EEC : CE Marking
  • Using UL94-VO recognized materials
  • EN 50121-3-2:2006: Railway EMC standard
  • EN 50124-1:2001: Insulation levels
  • EN 50178:1997: for industrial applications
  • NFF 16101/2: Fire and smoke classification
  • Developed according to IRIS standard

Remarks:

  • New innovative patented insulating digital technology
  • Economic, 30% power saving
  • 30% lighter
  • Unmatched immunity to electromagnetic disturbances
  • Insensitive to magnetic fields
  • 100% compatible with previous generations of transducers in performance and footprint

 
Electrical data
TypRated voltage
primary
VPN[V]
The measuring range of the primary voltage
VPM[V]

DVL 50

50 ±75

DVL 125

125 ± 187,5

DVL 150

150 ±225

DVL 250

250 ±375

DVL 500

500 ±750

DVL 750

750 ± 1125

DVL 1000

1000 ± 1500

DVL 1500

1500 ±2250

DVL 2000

2000 ±3000

Dimensions [mm]: Series DVL



Wiring diagram

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Voltage transducers for Industrial and Traction - for small and medium voltage measurements

Main characteristics:

  • Compact design
  • A unique design to cover all measuring ranges
  • Voltage measurement from 50 to 2000 VRMS
  • High level of insulation test voltage: 8.5 KVRMS / 50 Hz / 1 min
  • High level of RMS voltage (2.7 kV) for partial discharges extinction @10 pC
  • Excellent overall accuracy:
    • +/- 0.4% of Vpn at + 25°C
    • +/- 1% of Vpn over the operating temperature range
  • High bandwidth (short response time): 14 KHz (-3 dB)

Features:

  • DC, AC and pulse voltage measurements with galvanic isolation
  • Power supply: +/- 13,5 ...26,4 V
  • Operating temperature range: -40°C to +85°C
  • Flexibility with modular connections for primary and secondary sides (connectors, shielded cables, terminals ...)
  • Current output as +/- 50 mA or current loop 4 to 20 mA

Standard compliance:

  • EN50155:2007 for traction applications such as:
    • Main and auxiliary converters
    • Circuit breaker
    • Substations
    • Battery chargers
    • Propulsion and braking chopper
    • but also industrial applications
  • European Directive EMC 2004 / 108 / EEC : CE Marking
  • Using UL94-VO recognized materials
  • EN 50121-3-2:2006: Railway EMC standard
  • EN 50124-1:2001: Insulation levels
  • EN 50178:1997: for industrial applications
  • NFF 16101/2: Fire and smoke classification
  • Developed according to IRIS standard

Remarks:

  • New innovative patented insulating digital technology
  • Economic, 30% power saving
  • 30% lighter
  • Unmatched immunity to electromagnetic disturbances
  • Insensitive to magnetic fields
  • 100% compatible with previous generations of transducers in performance and footprint

 
Electrical data
TypRated voltage
primary
VPN[V]
The measuring range of the primary voltage
VPM[V]

DVL 50

50 ±75

DVL 125

125 ± 187,5

DVL 150

150 ±225

DVL 250

250 ±375

DVL 500

500 ±750

DVL 750

750 ± 1125

DVL 1000

1000 ± 1500

DVL 1500

1500 ±2250

DVL 2000

2000 ±3000

Dimensions [mm]: Series DVL



Wiring diagram