Traktionsspannungswandler DV 4200 / SP4
  • Traktionsspannungswandler DV 4200 / SP4

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: LEM

Traktionsspannungswandler DV 4200 / SP4

Measures DC, AC, Pulse voltage with galvanic insulation between primary and secondary circuit.

Characteristics
• double direction, insulated voltage measurement up to 6kV
• Current input signal
• Connection of primary and secondary circuits with M5 screw

Advantages:
• Low current consumption
• Compact construction
• Excellent accuracy
• response time: 60µs
• Small temperature offset
• High resistance for external noise

Application
• Traction
• One and three phase inverters
• Driver inverters
• High power drives
• Energy measurement on the traction vehicle

Trakcyjny przetwornik napięciowy DV 4200/SP4
 

Electrical Data

Primary nominal RMS voltage VPN 4200 V
Primary voltage, measuring range VPM ±6000 V
Measuring resistance RM 0..140 Ω
Secondary nominal RMS current ISN 50 mA
Secondary current IS ±71.4 mA
Supply voltage ±UC ±24 Vdc
Current consumption IC (20 + IS) mA
Overall accuracy XG ±0.3% of VPN (@25°C, 100% tested in production)
Linearity error EL ±0.1% of VPM
Frequency bandwidth BW  0..12 kHz
RMS voltage for AC insulation test (50 Hz, 1 min) Ud 18.5 kV (100% tested in production)
Ambient operating temperature TA -40..+85 °C
Mass m 620 g
Norms: EN50155: 2007
EN50121-3-2 : 2006
EN50124-1 : 2001


Dimensions [mm]: DV 4200/SP4
Trakcyjny przetwornik napięciowy DV 4200/SP4

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Measures DC, AC, Pulse voltage with galvanic insulation between primary and secondary circuit.

Characteristics
• double direction, insulated voltage measurement up to 6kV
• Current input signal
• Connection of primary and secondary circuits with M5 screw

Advantages:
• Low current consumption
• Compact construction
• Excellent accuracy
• response time: 60µs
• Small temperature offset
• High resistance for external noise

Application
• Traction
• One and three phase inverters
• Driver inverters
• High power drives
• Energy measurement on the traction vehicle

Trakcyjny przetwornik napięciowy DV 4200/SP4
 

Electrical Data

Primary nominal RMS voltage VPN 4200 V
Primary voltage, measuring range VPM ±6000 V
Measuring resistance RM 0..140 Ω
Secondary nominal RMS current ISN 50 mA
Secondary current IS ±71.4 mA
Supply voltage ±UC ±24 Vdc
Current consumption IC (20 + IS) mA
Overall accuracy XG ±0.3% of VPN (@25°C, 100% tested in production)
Linearity error EL ±0.1% of VPM
Frequency bandwidth BW  0..12 kHz
RMS voltage for AC insulation test (50 Hz, 1 min) Ud 18.5 kV (100% tested in production)
Ambient operating temperature TA -40..+85 °C
Mass m 620 g
Norms: EN50155: 2007
EN50121-3-2 : 2006
EN50124-1 : 2001


Dimensions [mm]: DV 4200/SP4
Trakcyjny przetwornik napięciowy DV 4200/SP4