HTR 50 TO 500-SB transducers
  • HTR 50 TO 500-SB transducers

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

HTR 50 TO 500-SB transducers

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB