BackX
-
All categories
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Transducers for Protection, Monitoring and Control | LEM
- Split-core Transducers | LEM
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Drivers and Panels
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
SERVICE, REPAIRS
-
-
Installation of equipment
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Medium Voltage Program UGE-UGZ single-pole and double-pole indoor voltage transformers
UCE/UCZ indoor voltage transformers are used for measuring and protection purposes, especially in medium-voltage switch gear up to Um = 24 kV.
Safety by design
The voltage transformers of the UGE/UGZ series are encapsulated in an epoxy-resin housing, i.e. the primary and secondary windings and the leg core are embedded in a single operation, thus guaranteeing optimum insulation resistance.
The output terminals consist of an M5 terminal pair. One screw of each terminal can be used for direct earthing to the base plate. An M8 earthing terminal is located on the back of the transformer housing. The output terminals are protected against accidental contact by a sealable transparent cover in self-extinguishing polycarbonate.
UGE single-pole insulated voltage transformers: Primary and secondary windings are insulated from each other for 3 kV in accordance with the required power frequency withstand voltage. The primary winding is connected to earth via an M5 screw in the terminal box before leaving the factory.
For models with winding intended to produce a residue! voltage always ensure that when using an open delta system connection to earth is made at only one point of the open delta I
UGZ double-pole insulated voltage transformers: Primary ond secondary windings are insulated from each other according to the highest service voltage and the associated rated insulation levels. During the final inspection the transformers are subjected to a routine test in accordance with the relevant national and international standards such as VDE, IEC BS, ANSI etc..
Technical data
Single pole | Double pole | |||
---|---|---|---|---|
UGE12A3 |
UGE24B3 |
UGZ12A3 |
UGZ24B3 |
|
Rated insulation level | 12/28/75kV | 24/50/125kV | 12/28/75kV | 24/50/125kV |
Rated primary voltage | 6,6kV/√ 3 10kV/√3 |
15kV/√3 20kV/√3 |
6,6kV 10kV |
15kV 20kV |
Rated secondary voltage of metering windig | 100V/√3, 110V/√3 | 100V, 110V | ||
Rated frequency | 50Hz, 60Hz | |||
Rated burden in class | 0,2 15VA, 30VA 0,5 50VA, 100VA 1 100VA, 200VA 3 250VA, 500VA |
20VA, 45VA 50VA, 100VA 100VA, 200VA 250VA, 500VA |
15VA, 30VA 50VA, 100VA 100VA, 200VA 250VA, 500VA |
20VA, 45VA 50VA, 100VA 100VA, 200VA 250VA, 500VA |
Rated secondary voltage of residuel voltage winding | 100V/√3, 110V/√3 | - | ||
Rated burden fo protection purpose in class | 3P 60VA 6P 60VA |
100VA 100VA |
- - |
- - |
Rated thermal limiting output of residuel voltage winding | 100VA | 100VA | - | - |
Rated thermal limiting outpur | 600VA | 600VA | 400VA | 400VA |
Insulation class | E | |||
Ambient temperature | -5……+35°C | |||
Alititude of insallation above sea level | 1000m n.p.m. | |||
Standard | VDE, IEC |
Type | L | B | H | a | b | d | m | n | x | y | z |
---|---|---|---|---|---|---|---|---|---|---|---|
UGE12A3 |
347 | 148 | 232 | 280 | 125 | 12 | 90 | 110 | 190 | - | - |
UGZ12A3 |
347 | 148 | 232 | 280 | 125 | 12 | - | 115 | 190 | 100 | 110 |
UGE24B3 |
355 | 178 | 292 | 290 | 150 | 12 | 200 | 220 | 200 | - | - |
UGZ24B3 |
355 | 178 | 292 | 290 | 150 | 14 | - | 220 | 200 | 165 | 130 |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Medium Voltage Program UGE-UGZ single-pole and double-pole indoor voltage transformers
UCE/UCZ indoor voltage transformers are used for measuring and protection purposes, especially in medium-voltage switch gear up to Um = 24 kV.
Safety by design
The voltage transformers of the UGE/UGZ series are encapsulated in an epoxy-resin housing, i.e. the primary and secondary windings and the leg core are embedded in a single operation, thus guaranteeing optimum insulation resistance.
The output terminals consist of an M5 terminal pair. One screw of each terminal can be used for direct earthing to the base plate. An M8 earthing terminal is located on the back of the transformer housing. The output terminals are protected against accidental contact by a sealable transparent cover in self-extinguishing polycarbonate.
UGE single-pole insulated voltage transformers: Primary and secondary windings are insulated from each other for 3 kV in accordance with the required power frequency withstand voltage. The primary winding is connected to earth via an M5 screw in the terminal box before leaving the factory.
For models with winding intended to produce a residue! voltage always ensure that when using an open delta system connection to earth is made at only one point of the open delta I
UGZ double-pole insulated voltage transformers: Primary ond secondary windings are insulated from each other according to the highest service voltage and the associated rated insulation levels. During the final inspection the transformers are subjected to a routine test in accordance with the relevant national and international standards such as VDE, IEC BS, ANSI etc..
Technical data
Single pole | Double pole | |||
---|---|---|---|---|
UGE12A3 |
UGE24B3 |
UGZ12A3 |
UGZ24B3 |
|
Rated insulation level | 12/28/75kV | 24/50/125kV | 12/28/75kV | 24/50/125kV |
Rated primary voltage | 6,6kV/√ 3 10kV/√3 |
15kV/√3 20kV/√3 |
6,6kV 10kV |
15kV 20kV |
Rated secondary voltage of metering windig | 100V/√3, 110V/√3 | 100V, 110V | ||
Rated frequency | 50Hz, 60Hz | |||
Rated burden in class | 0,2 15VA, 30VA 0,5 50VA, 100VA 1 100VA, 200VA 3 250VA, 500VA |
20VA, 45VA 50VA, 100VA 100VA, 200VA 250VA, 500VA |
15VA, 30VA 50VA, 100VA 100VA, 200VA 250VA, 500VA |
20VA, 45VA 50VA, 100VA 100VA, 200VA 250VA, 500VA |
Rated secondary voltage of residuel voltage winding | 100V/√3, 110V/√3 | - | ||
Rated burden fo protection purpose in class | 3P 60VA 6P 60VA |
100VA 100VA |
- - |
- - |
Rated thermal limiting output of residuel voltage winding | 100VA | 100VA | - | - |
Rated thermal limiting outpur | 600VA | 600VA | 400VA | 400VA |
Insulation class | E | |||
Ambient temperature | -5……+35°C | |||
Alititude of insallation above sea level | 1000m n.p.m. | |||
Standard | VDE, IEC |
Type | L | B | H | a | b | d | m | n | x | y | z |
---|---|---|---|---|---|---|---|---|---|---|---|
UGE12A3 |
347 | 148 | 232 | 280 | 125 | 12 | 90 | 110 | 190 | - | - |
UGZ12A3 |
347 | 148 | 232 | 280 | 125 | 12 | - | 115 | 190 | 100 | 110 |
UGE24B3 |
355 | 178 | 292 | 290 | 150 | 12 | 200 | 220 | 200 | - | - |
UGZ24B3 |
355 | 178 | 292 | 290 | 150 | 14 | - | 220 | 200 | 165 | 130 |