Galios reguliatoriai - GAC
  • Galios reguliatoriai - GAC

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: DACPOL SERVICE

Galios reguliatoriai - GAC

Power controllers - GAC


Use:
Power control of furnaces with resistance heaters, high-power thermal fans, air conditioners with electric heating, paint dryers.

Features:
Long service life, resistance to power line surges, surge-free on/off switching of loads, quiet operation, compliance with PN-EN 60947-4-3.



Technical data

 
Type GAC1 GAC2 GAC3
Power supply
3x400 V, 50 Hz
Max. current load
30 A, 40 A, 50 A 60 A, 80 A, 100 A, 120 A, 160 A, 180 A 250 A, 400 A
Power supply tolerance
-15% ÷ +10%Un
Category of use AC-51
Features power status, full conduction status, switching function
Control signals* 0-10 VDC
4-20 mA
Thyristors control
group
Receiver connection system star or delta
Surge protection RC suppressor
Cooling air
Ingress Protection
IP00
Insulation test voltage 2,5 kV
Degree of contamination 3
Operating temperature range
0 ÷ 50 °C
Storage temperature range
-20 °C ÷ 60 °C
Shielding metaplex
Short-circuit protection
fast fuses
Relative humidity
up to 85% (no condensation)
Altitude up to 1000 m
Rectangle of fixing holes 155 x 175 mm

155 x 175 mm (GAC2 60 i 80);
280 x 155 mm (other)

280 x 410 mm
Dimensions (L x W x H) 200 x 185 x 255 mm 240 x 185 x 255 mm (DAC 60 i 80);
340 x 175 x 255 mm (other)
340 x 380 x 260 mm
Weight 5,5 kg 6-9,5 kg 28 kg

Attention:
*Please specify the type of control signal in your order.

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

Power controllers - GAC


Use:
Power control of furnaces with resistance heaters, high-power thermal fans, air conditioners with electric heating, paint dryers.

Features:
Long service life, resistance to power line surges, surge-free on/off switching of loads, quiet operation, compliance with PN-EN 60947-4-3.



Technical data

 
Type GAC1 GAC2 GAC3
Power supply
3x400 V, 50 Hz
Max. current load
30 A, 40 A, 50 A 60 A, 80 A, 100 A, 120 A, 160 A, 180 A 250 A, 400 A
Power supply tolerance
-15% ÷ +10%Un
Category of use AC-51
Features power status, full conduction status, switching function
Control signals* 0-10 VDC
4-20 mA
Thyristors control
group
Receiver connection system star or delta
Surge protection RC suppressor
Cooling air
Ingress Protection
IP00
Insulation test voltage 2,5 kV
Degree of contamination 3
Operating temperature range
0 ÷ 50 °C
Storage temperature range
-20 °C ÷ 60 °C
Shielding metaplex
Short-circuit protection
fast fuses
Relative humidity
up to 85% (no condensation)
Altitude up to 1000 m
Rectangle of fixing holes 155 x 175 mm

155 x 175 mm (GAC2 60 i 80);
280 x 155 mm (other)

280 x 410 mm
Dimensions (L x W x H) 200 x 185 x 255 mm 240 x 185 x 255 mm (DAC 60 i 80);
340 x 175 x 255 mm (other)
340 x 380 x 260 mm
Weight 5,5 kg 6-9,5 kg 28 kg

Attention:
*Please specify the type of control signal in your order.