HTR 50 iki 500-SB serijos keitikliai
  • HTR 50 iki 500-SB serijos keitikliai

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: LEM

HTR 50 iki 500-SB serijos keitikliai

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB