Нагрев стальных труб для склеивания
  • Нагрев стальных труб для склеивания

Фотографии предназначены только для информационных целей. Посмотреть спецификацию продукта

please use latin characters

Производитель: Ambrell

Нагрев стальных труб для склеивания

Heating Steel Tubes for an Adhesive Bonding Application


Objective: To heat steel tubes for an adhesive bonding application for a medical industry part.


Frequency: 230 kHz


Equipment:
  • Ambrell EASYHEATTM 1.2 kW, 150-400 kHz induction heating system equipped with a remote workhead;
  • A single position multiple-turn helical coil designed specifically for this application.

Material: A stainless steel tube on a plastic tube


Temperature: 392 °F (200 °C)


Process:

Initial tests were conducted to optimize the power delivered to the plastic tube assembly. Temperature indicating paint was then applied to the part, which dissolves when the part reaches the target temperature. It was observed that it took 5.0 seconds to heat the sample to temperature. After the part cooled to room temperature, it was compared to the customer-provided finished assemblies to confirm that the plastic was sufficiently bonded to the inside of the steel tube. Five assemblies were heated and the application was successfully proven out.


Benefits:
  • Fast, Precise Heating: It took just 5 seconds with our lowest power unit to deliver the heat just where it was needed for this bonding application;
  • Footprint: The EASYHEAT takes up a modest footprint, making it an easy addition to this client’s process;
  • Repeatability: The client wanted the same result every time, which induction from Ambrell delivers;

Отправить запрос

Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?

Свяжитесь с нами

СПРОСИТЕ ПРОДУКТ close
Сообщение успешно отправлено.
СПРОСИТЕ ПРОДУКТ close
Просматривать

Добавить в список желаний

Вы должны быть зарегистрированы

Heating Steel Tubes for an Adhesive Bonding Application


Objective: To heat steel tubes for an adhesive bonding application for a medical industry part.


Frequency: 230 kHz


Equipment:
  • Ambrell EASYHEATTM 1.2 kW, 150-400 kHz induction heating system equipped with a remote workhead;
  • A single position multiple-turn helical coil designed specifically for this application.

Material: A stainless steel tube on a plastic tube


Temperature: 392 °F (200 °C)


Process:

Initial tests were conducted to optimize the power delivered to the plastic tube assembly. Temperature indicating paint was then applied to the part, which dissolves when the part reaches the target temperature. It was observed that it took 5.0 seconds to heat the sample to temperature. After the part cooled to room temperature, it was compared to the customer-provided finished assemblies to confirm that the plastic was sufficiently bonded to the inside of the steel tube. Five assemblies were heated and the application was successfully proven out.


Benefits:
  • Fast, Precise Heating: It took just 5 seconds with our lowest power unit to deliver the heat just where it was needed for this bonding application;
  • Footprint: The EASYHEAT takes up a modest footprint, making it an easy addition to this client’s process;
  • Repeatability: The client wanted the same result every time, which induction from Ambrell delivers;