Measurement, visualization and recording of over 300 parameters of 3-phase balanced or unbalanced power network
| Inputs | |||
|---|---|---|---|
| Kind of input | Measuring range | Parameters | Basic error |
| Voltage input | 57,7/100 V, 230/400 V or 400/690 V |
0,05...1,2 Un | ± 0,2% |
| Current input | 1 A lub 5 A | 0,005...1,2 In | ± 0,2% |
| Logic input | 0/5...24 V d.c. | switch frequency up to 50 Hz | |
| Outputs | |
|---|---|
| Kind of output | Properties |
| Analog output | 4 programmable current outputs of 0/4...20 mA, load resistance < 500 Ω |
| Relay output | 6 programmable electromagnetic relays, voltageless NOC contacts, load capacity: 250 V a.c./1 A a.c. |
| Output to supply object transducers | 2 outputs of 24 V d.c./30 mA |
| Digital interfaces | |
|---|---|
| Interface type | Properties |
| RS-485 | 2 interfaces: MODBUS Slave and Master, baud rate: 300…256000 bit/s, transmission mode ASCII/RTU |
| USB | Device V.1.1, USBB-G socket |
| Ethernet | 10 Base-T, RJ45socket, Modbus Slave TCP/IP |
| Rated operating conditions | ||
|---|---|---|
| Supply voltage | 85...230...253 V a.c./d.c., 40...400 Hz a.c | Power consumption ≤ 30 VA |
| Ambient temperature | Work 0...23...50°C | Storage:: - 20...60°C |
| Relative humidity | < 70% | Condensation inadmissible |
| Reaction against | supply decays | Data and device state preservation |
| powrót zasilania: | Continuation of device work | |
| Short term load (5s) | 2 Un (max. 1000 V) | 10 In |
| Casing protection grade | From frontal side: IP 65 | From terminal side: IP20 |
| Safety requirements | Installation category: II | EN 61010-1 |
| Pollution grade: 2 | ||
| Maximum phase-to-earth operating voltage |
From the measuring system, relays and supply: 500 V | |
| For RS-485 and USB interfaces: 50 V | ||
| Measuring ranges and admissible basic conversion errors | |||
|---|---|---|---|
| Measuring quantity | Range | Basic error | Remarks |
| Voltage U | 57,73 / 100,0 V (Ku = 1) 230,0 / 400,0 V (Ku = 1) 400,0 / 690,0 V (Ku = 1) 400,0 kV (Ku ≠ 1) |
± 0,2 % | Ku = 1...4000 |
| Current I | 1,000 A (Ki = 1) 5,000 A (Ki = 1) 100,0 kA (Ki ≠ 1) |
± 0,2 % | Ki = 1...20000 |
| Active power P Mean active power Pav |
0,0… (-) 6000,0 W 999,00 MW (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
| Apparent power S | 0,0…6000,0 VA 999,00 MVA (Ku ≠ 1, Ki ≠ 1) | ± 0,5 % | |
| Reactive power Q | 0,0…(-) 6000,0 VA 999,00 MV (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
| Active power factor PF | -1,000…0…1,000 | ± 0,5 % | PF = Power Factor = P/S |
| Coefficient tφ | -10,00…0…10,00 | ± 1 % | Ratio of active power to reactive |
| φ angle between U and I | -180°...180° | ± 0,5 % | Evaluated from the power triangle |
| Frequency f | 45,00...66,00 Hz | ± 0,1 % | |
| THD U, THD I Harmonics U, I (up to 51) |
0…200,0 % 0…100,0 % | ± 2 % | Error in the range 10…120 % U,I |
| PST, PLT | 0..20 | ± 0,5 % | in range of 0.05..35 Hz |
| Active energy EnP | 0…(-) 99 999 999,9 kWh | ± 0,5 % | |
| Reactive energy EnQ | 0… (-) 99 999 999,9 kvarh | ± 0,5 % | |
where:
Ku voltage transformer ratio
Ki current transformer ratio
THD U total coefficient of voltage harmonic distortion
THD I total coefficient of current harmonic distortion,

EXAMPLE OF ORDER:
The code ND1 - 2 1 00 E 0 means:
ND1 - analyser of 3-phase power network
parameters of ND1 type
2 - current input: 5 A
1 - voltage input: 57.7/100 V
00 - standard version
E - English language
0 - without extra quality requirements.
NOTE:
Each ND1 analyser is equiped with 6 alarms (electromecanic relays), 4 analog outputs, 12 logic inputs and Ethernet interface..

Various forms of data display: ,
Manual and automatic switching between screens.






| Housing view from frontal side | Housing view from rear view |

1301-130-903 – wire MLS R, 2m, black
1301-130-902 – crocodile terminal AK-2B 2540, black
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы

Measurement, visualization and recording of over 300 parameters of 3-phase balanced or unbalanced power network
| Inputs | |||
|---|---|---|---|
| Kind of input | Measuring range | Parameters | Basic error |
| Voltage input | 57,7/100 V, 230/400 V or 400/690 V |
0,05...1,2 Un | ± 0,2% |
| Current input | 1 A lub 5 A | 0,005...1,2 In | ± 0,2% |
| Logic input | 0/5...24 V d.c. | switch frequency up to 50 Hz | |
| Outputs | |
|---|---|
| Kind of output | Properties |
| Analog output | 4 programmable current outputs of 0/4...20 mA, load resistance < 500 Ω |
| Relay output | 6 programmable electromagnetic relays, voltageless NOC contacts, load capacity: 250 V a.c./1 A a.c. |
| Output to supply object transducers | 2 outputs of 24 V d.c./30 mA |
| Digital interfaces | |
|---|---|
| Interface type | Properties |
| RS-485 | 2 interfaces: MODBUS Slave and Master, baud rate: 300…256000 bit/s, transmission mode ASCII/RTU |
| USB | Device V.1.1, USBB-G socket |
| Ethernet | 10 Base-T, RJ45socket, Modbus Slave TCP/IP |
| Rated operating conditions | ||
|---|---|---|
| Supply voltage | 85...230...253 V a.c./d.c., 40...400 Hz a.c | Power consumption ≤ 30 VA |
| Ambient temperature | Work 0...23...50°C | Storage:: - 20...60°C |
| Relative humidity | < 70% | Condensation inadmissible |
| Reaction against | supply decays | Data and device state preservation |
| powrót zasilania: | Continuation of device work | |
| Short term load (5s) | 2 Un (max. 1000 V) | 10 In |
| Casing protection grade | From frontal side: IP 65 | From terminal side: IP20 |
| Safety requirements | Installation category: II | EN 61010-1 |
| Pollution grade: 2 | ||
| Maximum phase-to-earth operating voltage |
From the measuring system, relays and supply: 500 V | |
| For RS-485 and USB interfaces: 50 V | ||
| Measuring ranges and admissible basic conversion errors | |||
|---|---|---|---|
| Measuring quantity | Range | Basic error | Remarks |
| Voltage U | 57,73 / 100,0 V (Ku = 1) 230,0 / 400,0 V (Ku = 1) 400,0 / 690,0 V (Ku = 1) 400,0 kV (Ku ≠ 1) |
± 0,2 % | Ku = 1...4000 |
| Current I | 1,000 A (Ki = 1) 5,000 A (Ki = 1) 100,0 kA (Ki ≠ 1) |
± 0,2 % | Ki = 1...20000 |
| Active power P Mean active power Pav |
0,0… (-) 6000,0 W 999,00 MW (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
| Apparent power S | 0,0…6000,0 VA 999,00 MVA (Ku ≠ 1, Ki ≠ 1) | ± 0,5 % | |
| Reactive power Q | 0,0…(-) 6000,0 VA 999,00 MV (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
| Active power factor PF | -1,000…0…1,000 | ± 0,5 % | PF = Power Factor = P/S |
| Coefficient tφ | -10,00…0…10,00 | ± 1 % | Ratio of active power to reactive |
| φ angle between U and I | -180°...180° | ± 0,5 % | Evaluated from the power triangle |
| Frequency f | 45,00...66,00 Hz | ± 0,1 % | |
| THD U, THD I Harmonics U, I (up to 51) |
0…200,0 % 0…100,0 % | ± 2 % | Error in the range 10…120 % U,I |
| PST, PLT | 0..20 | ± 0,5 % | in range of 0.05..35 Hz |
| Active energy EnP | 0…(-) 99 999 999,9 kWh | ± 0,5 % | |
| Reactive energy EnQ | 0… (-) 99 999 999,9 kvarh | ± 0,5 % | |
where:
Ku voltage transformer ratio
Ki current transformer ratio
THD U total coefficient of voltage harmonic distortion
THD I total coefficient of current harmonic distortion,

EXAMPLE OF ORDER:
The code ND1 - 2 1 00 E 0 means:
ND1 - analyser of 3-phase power network
parameters of ND1 type
2 - current input: 5 A
1 - voltage input: 57.7/100 V
00 - standard version
E - English language
0 - without extra quality requirements.
NOTE:
Each ND1 analyser is equiped with 6 alarms (electromecanic relays), 4 analog outputs, 12 logic inputs and Ethernet interface..

Various forms of data display: ,
Manual and automatic switching between screens.






| Housing view from frontal side | Housing view from rear view |

1301-130-903 – wire MLS R, 2m, black
1301-130-902 – crocodile terminal AK-2B 2540, black