Główny wyłącznik obwodu Ex 250A EXKO 73 1813 D0001
Główny wyłącznik obwodu Ex 250A EXKO 73 1813 D0001

A fényképek csak tájékoztató jellegűek. Lásd a termék specifikációit

Kérjük, használjon latin karaktereket

Gyártó: Eaton / CEAG

Main circuit breaker Ex 250A EXKO 73 1813 D0001

  • EXKO 73 1813 D0001
  • Anyag
  • Prąd znamionowy
  • Klasa IP
  • Cable gland

Safety for your protection

CEAG main circuit breakers enable the connection or disconnection of circuits under normal operating conditions, as well as the switching, short-term conduction, and interruption of currents in exceptional situations, such as short circuits.

Full switching capacity for motors in the AC-3 category

Full switching capacity for motors in the AC-3 category and insulation properties in accordance with the EN 60947-4-1 standard with mandatory opening of the main contacts in accordance with the EN 60204-1 standard are just some of the important features offered by CEAG circuit breakers.

Versions up to 180 A optionally offer a high degree of protection of IP66. The switch position is always clearly visible and easy to recognize.

The main circuit breakers feature an installation-friendly design and easily accessible connection terminals.

Metal versions can be equipped with screw-on flanges for easy system integration and cost-effective service life extension. Optionally, they can be supplied with plastic or brass snap-on flanges.

These circuit breakers are also available in versions for Explosion Group IIB, which is sufficient for many applications.

Parameter Specification
Marking according to 2014/34/EU II 2 G Ex de ia/ib[ia/ib] IIC T4 – T6*
II 2 D IP66 T80 °C / T95 °C / T130 °C
EC-Type Examination Certificate PTB 99 ATEX 1057
IECEx Certificate of Conformity IECEx PTB 12.0026
Marking according to IECEx Ex d IIC T6, T5, or T4 Gb / Ex de IIC T6, T5, or T4 Gb
Ex d IIB T6, T5, or T4 Gb / Ex de IIB T6, T5, or T4 Gb
Permissible ambient temperature –20 °C to +40 °C**
Rated voltage up to max. 690 V
Rated current max. 250 A
Frequency 50/60 Hz
Rated making/breaking capacity AC-3 according to EN 60947-3 Ue 230 V / Ie 250 A
Ue 400 V / Ie 250 A
Ue 500 V / Ie 250 A
Ue 690 V / Ie 250 A
Fuse fuse up to 400 V AC: 250 A gG
up to 500 V AC: 250 A gG
up to 690 V AC: 250 A gG
Connection terminals – main contact 150/95 mm²
Protection class I
Protection degree according to EN 60529 IP54 (optional IP65)
Cable glands / mounting holes M63 gland – see order details
Weight 3-pole version: approx. 50 kg
4-pole version: approx. 55 kg
Housing material powder-coated aluminum polyester, junction box powder-coated steel
Color Aluminum housing: gray (RAL 7032)
Steel housing: dark gray (RAL 7022)

*Also available for explosion group IIB
**Other ambient temperatures available upon request

Ajánlatkérés küldése

Érdekel ez a termék? További információra vagy egyedi árajánlatra van szüksége?

Lépjen kapcsolatba velünk
Kérdezzen a termékről close
Köszönjük az üzenetét Amint lehet, válaszolunk
Kérdezzen a termékről close
Böngésszen

Add to wishlist

Musisz być zalogowany/a

  • Anyag
  • Prąd znamionowy
  • Klasa IP
  • Cable gland

Safety for your protection

CEAG main circuit breakers enable the connection or disconnection of circuits under normal operating conditions, as well as the switching, short-term conduction, and interruption of currents in exceptional situations, such as short circuits.

Full switching capacity for motors in the AC-3 category

Full switching capacity for motors in the AC-3 category and insulation properties in accordance with the EN 60947-4-1 standard with mandatory opening of the main contacts in accordance with the EN 60204-1 standard are just some of the important features offered by CEAG circuit breakers.

Versions up to 180 A optionally offer a high degree of protection of IP66. The switch position is always clearly visible and easy to recognize.

The main circuit breakers feature an installation-friendly design and easily accessible connection terminals.

Metal versions can be equipped with screw-on flanges for easy system integration and cost-effective service life extension. Optionally, they can be supplied with plastic or brass snap-on flanges.

These circuit breakers are also available in versions for Explosion Group IIB, which is sufficient for many applications.

Parameter Specification
Marking according to 2014/34/EU II 2 G Ex de ia/ib[ia/ib] IIC T4 – T6*
II 2 D IP66 T80 °C / T95 °C / T130 °C
EC-Type Examination Certificate PTB 99 ATEX 1057
IECEx Certificate of Conformity IECEx PTB 12.0026
Marking according to IECEx Ex d IIC T6, T5, or T4 Gb / Ex de IIC T6, T5, or T4 Gb
Ex d IIB T6, T5, or T4 Gb / Ex de IIB T6, T5, or T4 Gb
Permissible ambient temperature –20 °C to +40 °C**
Rated voltage up to max. 690 V
Rated current max. 250 A
Frequency 50/60 Hz
Rated making/breaking capacity AC-3 according to EN 60947-3 Ue 230 V / Ie 250 A
Ue 400 V / Ie 250 A
Ue 500 V / Ie 250 A
Ue 690 V / Ie 250 A
Fuse fuse up to 400 V AC: 250 A gG
up to 500 V AC: 250 A gG
up to 690 V AC: 250 A gG
Connection terminals – main contact 150/95 mm²
Protection class I
Protection degree according to EN 60529 IP54 (optional IP65)
Cable glands / mounting holes M63 gland – see order details
Weight 3-pole version: approx. 50 kg
4-pole version: approx. 55 kg
Housing material powder-coated aluminum polyester, junction box powder-coated steel
Color Aluminum housing: gray (RAL 7032)
Steel housing: dark gray (RAL 7022)

*Also available for explosion group IIB