Installing safe lighting in an explosive atmosphere is a non-negotiable requirement. Sammode designed the SABATIER luminaire with T5 Gas certification, designed for intensive use at temperatures up to 50°C. This model can withstand vibration and chemical attack thanks to its 5mm thick borosilicate glass. The SABATIER luminaire is equipped with a cable gland and a cable with an ATEX plug. A wide range of power supply options are available, ensuring durable lighting for any zone, regardless of its extreme conditions.
Cable input | ||
---|---|---|
Connector type | Cable diameter range | Code |
1 gland | Ø8–13 mm (polyamide) | 113 |
Ø10–15 mm (polyamide) | 116 | |
Ø6–14 mm (nickel-plated brass) | 113LN | |
2 glands (including one plugged) | Ø8–13 mm (polyamide) | 213 |
Ø10–15 mm (polyamide) | 216 | |
Ø6–14 mm (nickel-plated brass) | 213LN |
Mounting Brackets | |
---|---|
Bracket Type | Code |
Reinforced Mounting Brackets | BRS |
Reinforced Brackets with Screw HSHC | BRV |
Color temperature | |
---|---|
Color temperature | Code |
4000K | 840 |
Materials | |
---|---|
Element | Code |
Polycarbonate housing | PO |
Co-extruded PC/PMMA housing with high chemical resistance | POME |
304L Stainless Steel End Caps and Clamps | - |
316L Stainless Steel End Caps and Clamps | MR |
Technical Characteristics | |
---|---|
Category | Description |
Light Source | Efficient, replaceable LED module (CRI>80, 3 SDCM), 50,000 h L80/B10 at maximum operating temperature |
Optics | Special diffused optics with a satin finish |
Heat management system | Aluminum heatsink |
Driver | Highly reliable, mechanically reinforced DC driver thermally. Compatible with TN, TT and IT systems. Central Power Supply Compatibility |
Power Supply Voltage | 198–264V / 50/60Hz |
Electrical Class | Class I – Welded pin to input terminal and cover for potential equalization connections |
Temperature Range work | –20°C to +50°C |
Easy installation and maintenance | |
---|---|
Connection | ATEX cable gland made of polyamide for cables Ø8–13 mm • 1 cable: 3 x 2.5 mm² terminal block • 2 cables: 5 x 2.5 mm² terminal block |
Mounting | Mounting with 2 stainless steel screws, adjustable spacing and 360° rotation |
LED module maintenance | Easily replaceable LED modules and power supply. Voltage-free maintenance possible in an explosive atmosphere. |
Materials | |
---|---|
Housing | Borosilicate glass |
Caps and Mounting Brackets | 304L Stainless Steel |
Seals | Peroxide-cured EPDM |
Construction | One-piece housing with high mechanical and chemical resistance, tightness thanks to screw-type closing |
Norms | |
---|---|
ATEX / IECEx | IEC 60079-0, IEC 60079-7, IEC 60079-18, IEC 60079-31 |
Design | II 2G Ex eb mb IIC T5 Gb – II 2D Ex tb IIIC T80°C Db IP66 |
Temperature class | T5 (Gas) |
Ingress Protection | IP66, IP68, IP69K |
Impact Resistance (IK) | IK07 |
Fire Resistance | Non-Flammable |
Vibration resistance | Compliant with EN 60598-1 (tested according to IEC 60068-2-6) |
Érdekel ez a termék? További információra vagy egyedi árajánlatra van szüksége?
Musisz być zalogowany/a
Installing safe lighting in an explosive atmosphere is a non-negotiable requirement. Sammode designed the SABATIER luminaire with T5 Gas certification, designed for intensive use at temperatures up to 50°C. This model can withstand vibration and chemical attack thanks to its 5mm thick borosilicate glass. The SABATIER luminaire is equipped with a cable gland and a cable with an ATEX plug. A wide range of power supply options are available, ensuring durable lighting for any zone, regardless of its extreme conditions.
Cable input | ||
---|---|---|
Connector type | Cable diameter range | Code |
1 gland | Ø8–13 mm (polyamide) | 113 |
Ø10–15 mm (polyamide) | 116 | |
Ø6–14 mm (nickel-plated brass) | 113LN | |
2 glands (including one plugged) | Ø8–13 mm (polyamide) | 213 |
Ø10–15 mm (polyamide) | 216 | |
Ø6–14 mm (nickel-plated brass) | 213LN |
Mounting Brackets | |
---|---|
Bracket Type | Code |
Reinforced Mounting Brackets | BRS |
Reinforced Brackets with Screw HSHC | BRV |
Color temperature | |
---|---|
Color temperature | Code |
4000K | 840 |
Materials | |
---|---|
Element | Code |
Polycarbonate housing | PO |
Co-extruded PC/PMMA housing with high chemical resistance | POME |
304L Stainless Steel End Caps and Clamps | - |
316L Stainless Steel End Caps and Clamps | MR |
Technical Characteristics | |
---|---|
Category | Description |
Light Source | Efficient, replaceable LED module (CRI>80, 3 SDCM), 50,000 h L80/B10 at maximum operating temperature |
Optics | Special diffused optics with a satin finish |
Heat management system | Aluminum heatsink |
Driver | Highly reliable, mechanically reinforced DC driver thermally. Compatible with TN, TT and IT systems. Central Power Supply Compatibility |
Power Supply Voltage | 198–264V / 50/60Hz |
Electrical Class | Class I – Welded pin to input terminal and cover for potential equalization connections |
Temperature Range work | –20°C to +50°C |
Easy installation and maintenance | |
---|---|
Connection | ATEX cable gland made of polyamide for cables Ø8–13 mm • 1 cable: 3 x 2.5 mm² terminal block • 2 cables: 5 x 2.5 mm² terminal block |
Mounting | Mounting with 2 stainless steel screws, adjustable spacing and 360° rotation |
LED module maintenance | Easily replaceable LED modules and power supply. Voltage-free maintenance possible in an explosive atmosphere. |
Materials | |
---|---|
Housing | Borosilicate glass |
Caps and Mounting Brackets | 304L Stainless Steel |
Seals | Peroxide-cured EPDM |
Construction | One-piece housing with high mechanical and chemical resistance, tightness thanks to screw-type closing |
Norms | |
---|---|
ATEX / IECEx | IEC 60079-0, IEC 60079-7, IEC 60079-18, IEC 60079-31 |
Design | II 2G Ex eb mb IIC T5 Gb – II 2D Ex tb IIIC T80°C Db IP66 |
Temperature class | T5 (Gas) |
Ingress Protection | IP66, IP68, IP69K |
Impact Resistance (IK) | IK07 |
Fire Resistance | Non-Flammable |
Vibration resistance | Compliant with EN 60598-1 (tested according to IEC 60068-2-6) |