Фотографије су само у информативне сврхе. Погледајте спецификацију производа

please use latin characters

Произвођач: Chino

СР анализатор серије

The IM series is an on-line multi IR wavelength Mirror type analyzer utilizing the infrared absorption technology for measuring product constituent and/or thickness. Signal processing capabilities are built into the Compact All-In-One detector unit for easy installation and operation. A maximum of 99 calibration curves can be stored into the detector memory for numerous measurement applications. The detector can be used by itself or connected to a PC/plant control system, as both analog and digital outputs are provided. A remote setting display unit, connectable up to 9 detector units, can be used to setup various detector functions and also displays measured values.

Application:
• Measuring moisture of wood chip.
• Measuring the thickness of sheet or film.
• Measuring the organism, moisture and lipid of fodder.
• Measuring the organism, moisture and oil of potato chips.
• Measuring moisture of garbage (RDF moisture).
• Measuring the coating thickness on the painting sheet.
• Measuring moisture of powder.
• Measuring moisture in cleaning solution.
• Measuring moisture of clay.
• Measuring moisture of fiber.
• Measure [&] Control the coating thickness
of Laminate-sheet production line.
• Measure [&] Control the painting thickness.


Catalogue number

Features:
• Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism, and coating-thickness in real time simultaneously.
• Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
• High-speed [&] High-repeatability (28ms)
• Multi-calculation function
• Self-diagnostic function, easy maintenance.
• Conforms to CE standards and IP-65

Catalogue number
 
MEASURING EXAMPLES
Object Range Accu.
General moisture (%)
Glass / pottery / cement
Potter's clay 0...12 >±0.3
Iron / metal
Coal 0...15 >±0.2
Mix raw material 0...10 >±0.2
Iron oxide 0...10 >±0.2
Foods
Starch 0...25 >±0.2
Bread-crumbs 0...20 >±0.2
Soybean 0...15 >±0.2
Milk powder 0...5 >±0.2
Sugar / salt 0...2 >±0.05
Flavouring 0...10 >±0.2
Tea 0...15 >±0.2
Chemicals
Catalyst 0...10 >±0.2
Medium 0...20 >±0.2
Detergent 0...15 >±0.2
Ink 0...5 >±0.2
Fertilizer 0...5 >±0.2
Rubber / fiber / etc.
Vinylon fiber 0...10 >±0.2
Acrylic fiber 0...10 >±0.2
Wood chip 0...10 >±0.2
Paper 0...10 >±0.1
Material Range Accu.
Wet paper 40...70 >±0.5
Raw bread crumbs 30...40 >±0.7
Clay 0...30 >±0.3
Silica sand 0...10 >±0.8
Bicarbonate 0...18 >±0.6
Micro moisture
ABS, PVC powder 0...1 >±0.8
Granular ferrite 0...0.5 >±0.8
Thickness [um]
Polyethylene PE 10...3000 >+0.2
Polypropylene PP >±0.2
Polyester PET >±0.2
Vinyl chloride PVC >±0.2
PVA >±0.2
EVA >±0.2
Polystyrene PS >+0.2
Polycarbonate >±0.2
Nylon PA >±0.2
Polyimide PI >±0.3
TAC film >±0.2
Coating (g/m2)
Coat-paper 10...1000  
Tuck-paper, label  
Adhesive WET/DRY  
Resin on steel-board  
 
SOFTWARE PACKAGE
Main Screen
Displays measured data, trend and alarm value. Displays 4 constituents on one screen. Save data into specified folder, enable to search or
read out the data.

GENERAL SPECIFICATIONS
INFRARED MULTI ANALYZER
• Measuring system: Infrared absorption type
• Measuring wavelength: Up to 10 wavelengths
• Measuring component: Up to 4 constituents
• Light source: Tungsten lamp
• Measuring distance: 200...400 mm (IRMA 1300:160...300 mm)
• Measuring diameter: 50 mm3 / 300 mm (IRMA 1300: 30 mm3/200 mm
• Analog output: 4 to 20mADC, ±0.2% of full scale
(Load resistance: less than 500Ω)
• Communications:: RS485 MODBUS
• Output renewal cycle: 28 ms
• Display [&] setup: Displays data [&] setup parameter Parameters are configurable by key.
• Computing:: 2 or 3-color ratio calculation
Multiple regression calculation
• No. of calibration curve: Up to 99 curves
• Calibration curve: Linear, quadratic, cubic [&] multiple regression line
• Calibration curve correction: Linear [&] quadratic co
• Smoothing (delay): 0...99 sec
• Calibration: By checking plate
• Detector No. setup: When multiple detector operation,detector No. is key configurable.
• Channel No. setup: Calibration curve No. is key configurable.
• Self-diagnostic: Outputs contact signal and communications when abnormal
conditions.
• Correction input: Compensate measured value by external 4 to 20mA DC
(sample temperature, etc.)
• External Di/o: Di(contact input) --- Perform either oneof preset, data-hold or real/smoothing
Do(contact output) --- Selects self-diagnostic(1b) or Hi/low alarm(1a)
• Working temperature: 0 to 50°C (Use dry air cooling if higher than
45°C. Outlet air temperature must be lower
than 30°C.)
• Power supply: 24V DC supplied from IR-WEP (IR-WEP power supply: 100-240VAC)
• Power consumption:: ok. 30 VA
• Connection: terminal
• Casing: Aluminum casting, drip-proof structure
(conforming to IEC529, IP65)
• Weight: Approx. 4.3kg
• Mounting:: Bolt suspension method with 4 pieces
of M8 bolts
• CE-standards: EMC directives EN61326+A
   
SETTING DISPLAY UNIT  
•Input signal RS485, Up to 9 detectors connectable
• Analog output: 4 to 20mADC, 2 output* (Load resistance: less than 500Ω)
* When multiple detector operation, outputs for detector No. 1 [&] 2.
• Communications: RS232C, RS422 or RS485
• Output renewal cycle:: 28ms × detector number
Display: 1) Measured data, LED 5-digit
  2) Detector No., CH. No., Parameter setup
• Detector No. setup:: Detector No.1 to No.9 is key configurable.
• Calibration curve No. setup Calibration curve No. is key configurable.
• Smoothing time: T = 0,0...9,9 s, 10...99S
• Calibration:: Perform calibration by key operation or by external contact in use of checking plate
• Hold/preset: Hold or preset the display and output by key operation or external contact.
• Calibration curve correction: Online correction of calibration curve Linear or quadratic correction.
• External setup: Detector No., CH. No., Calibration,Hold or Preset.
• Alarm function:: Outputs contact signal (HCL) beyond
setting-range
• Self-diagnostic: Outputs contact signal(1b) when abnormal condition
With lamp display
• Power supply: 100...240VAC 50/60 Hz
• Power consumption: max. 15 VA
• Working ambient: 0...50 °C
• Casing: ABS
• Protection level IP65
• Mounting: Panel-mount type
• Weight:: Approx. 0.6kg
   
CE STANDARDS SPECIFICATIONS  
• Analog output:: 1x4...20mA
• Load resistance: <500n
• Power supply:: 24VDC±10%
• Power consumption: About 10VA
   
FIBER UNIT  
• Measuring distance and diameter: With lens --- φ25/25mm to φ40/100mm
  Without lens --- φ20/15mm to φ50/50mm
• Długość światłowodów: Standard 1.5m, Max.5m (Reflection type fiber)
  Standard 2m, Max.10m (Transmission type fiber)
• Fiber protection: Stainless steel flexible armour
• Minimum bending radius: r= 100 mm
• Working temperature: 0...150°C
• Purge air flow:: With lens --- Air purge disabled
  Without lens --- 5 to 20L/min
• Accessory:: Vertical mounting holder
  Flange holder

Dimensions [mm]:
Analyzer IRMA
Setting display unit IRGMEG2
Power supply unit IR-WEP
Air purge hood IR-WEA
Output checking plate IR-WEB
Connecting cable IR-WERP
Reflection type fiber
Reflection type fiber (with lens)
IR-WCRE
Transmission type fiber
Output checking plate for
reflection type fiber IR-WCRB
Liquid cell IR-WCC
Air-cooling box IR-WEX

Пошаљите упит

Да ли вас занима овај производ? Да ли су вам потребне додатне информације или појединачне цене?

Контактирајте нас

Питајте производ close
Порука је послата.
Питајте производ close
Прегледајте

Додај у листу жеља

морате бити пријављени

The IM series is an on-line multi IR wavelength Mirror type analyzer utilizing the infrared absorption technology for measuring product constituent and/or thickness. Signal processing capabilities are built into the Compact All-In-One detector unit for easy installation and operation. A maximum of 99 calibration curves can be stored into the detector memory for numerous measurement applications. The detector can be used by itself or connected to a PC/plant control system, as both analog and digital outputs are provided. A remote setting display unit, connectable up to 9 detector units, can be used to setup various detector functions and also displays measured values.

Application:
• Measuring moisture of wood chip.
• Measuring the thickness of sheet or film.
• Measuring the organism, moisture and lipid of fodder.
• Measuring the organism, moisture and oil of potato chips.
• Measuring moisture of garbage (RDF moisture).
• Measuring the coating thickness on the painting sheet.
• Measuring moisture of powder.
• Measuring moisture in cleaning solution.
• Measuring moisture of clay.
• Measuring moisture of fiber.
• Measure [&] Control the coating thickness
of Laminate-sheet production line.
• Measure [&] Control the painting thickness.


Catalogue number

Features:
• Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism, and coating-thickness in real time simultaneously.
• Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
• High-speed [&] High-repeatability (28ms)
• Multi-calculation function
• Self-diagnostic function, easy maintenance.
• Conforms to CE standards and IP-65

Catalogue number
 
MEASURING EXAMPLES
Object Range Accu.
General moisture (%)
Glass / pottery / cement
Potter's clay 0...12 >±0.3
Iron / metal
Coal 0...15 >±0.2
Mix raw material 0...10 >±0.2
Iron oxide 0...10 >±0.2
Foods
Starch 0...25 >±0.2
Bread-crumbs 0...20 >±0.2
Soybean 0...15 >±0.2
Milk powder 0...5 >±0.2
Sugar / salt 0...2 >±0.05
Flavouring 0...10 >±0.2
Tea 0...15 >±0.2
Chemicals
Catalyst 0...10 >±0.2
Medium 0...20 >±0.2
Detergent 0...15 >±0.2
Ink 0...5 >±0.2
Fertilizer 0...5 >±0.2
Rubber / fiber / etc.
Vinylon fiber 0...10 >±0.2
Acrylic fiber 0...10 >±0.2
Wood chip 0...10 >±0.2
Paper 0...10 >±0.1
Material Range Accu.
Wet paper 40...70 >±0.5
Raw bread crumbs 30...40 >±0.7
Clay 0...30 >±0.3
Silica sand 0...10 >±0.8
Bicarbonate 0...18 >±0.6
Micro moisture
ABS, PVC powder 0...1 >±0.8
Granular ferrite 0...0.5 >±0.8
Thickness [um]
Polyethylene PE 10...3000 >+0.2
Polypropylene PP >±0.2
Polyester PET >±0.2
Vinyl chloride PVC >±0.2
PVA >±0.2
EVA >±0.2
Polystyrene PS >+0.2
Polycarbonate >±0.2
Nylon PA >±0.2
Polyimide PI >±0.3
TAC film >±0.2
Coating (g/m2)
Coat-paper 10...1000  
Tuck-paper, label  
Adhesive WET/DRY  
Resin on steel-board  
 
SOFTWARE PACKAGE
Main Screen
Displays measured data, trend and alarm value. Displays 4 constituents on one screen. Save data into specified folder, enable to search or
read out the data.

GENERAL SPECIFICATIONS
INFRARED MULTI ANALYZER
• Measuring system: Infrared absorption type
• Measuring wavelength: Up to 10 wavelengths
• Measuring component: Up to 4 constituents
• Light source: Tungsten lamp
• Measuring distance: 200...400 mm (IRMA 1300:160...300 mm)
• Measuring diameter: 50 mm3 / 300 mm (IRMA 1300: 30 mm3/200 mm
• Analog output: 4 to 20mADC, ±0.2% of full scale
(Load resistance: less than 500Ω)
• Communications:: RS485 MODBUS
• Output renewal cycle: 28 ms
• Display [&] setup: Displays data [&] setup parameter Parameters are configurable by key.
• Computing:: 2 or 3-color ratio calculation
Multiple regression calculation
• No. of calibration curve: Up to 99 curves
• Calibration curve: Linear, quadratic, cubic [&] multiple regression line
• Calibration curve correction: Linear [&] quadratic co
• Smoothing (delay): 0...99 sec
• Calibration: By checking plate
• Detector No. setup: When multiple detector operation,detector No. is key configurable.
• Channel No. setup: Calibration curve No. is key configurable.
• Self-diagnostic: Outputs contact signal and communications when abnormal
conditions.
• Correction input: Compensate measured value by external 4 to 20mA DC
(sample temperature, etc.)
• External Di/o: Di(contact input) --- Perform either oneof preset, data-hold or real/smoothing
Do(contact output) --- Selects self-diagnostic(1b) or Hi/low alarm(1a)
• Working temperature: 0 to 50°C (Use dry air cooling if higher than
45°C. Outlet air temperature must be lower
than 30°C.)
• Power supply: 24V DC supplied from IR-WEP (IR-WEP power supply: 100-240VAC)
• Power consumption:: ok. 30 VA
• Connection: terminal
• Casing: Aluminum casting, drip-proof structure
(conforming to IEC529, IP65)
• Weight: Approx. 4.3kg
• Mounting:: Bolt suspension method with 4 pieces
of M8 bolts
• CE-standards: EMC directives EN61326+A
   
SETTING DISPLAY UNIT  
•Input signal RS485, Up to 9 detectors connectable
• Analog output: 4 to 20mADC, 2 output* (Load resistance: less than 500Ω)
* When multiple detector operation, outputs for detector No. 1 [&] 2.
• Communications: RS232C, RS422 or RS485
• Output renewal cycle:: 28ms × detector number
Display: 1) Measured data, LED 5-digit
  2) Detector No., CH. No., Parameter setup
• Detector No. setup:: Detector No.1 to No.9 is key configurable.
• Calibration curve No. setup Calibration curve No. is key configurable.
• Smoothing time: T = 0,0...9,9 s, 10...99S
• Calibration:: Perform calibration by key operation or by external contact in use of checking plate
• Hold/preset: Hold or preset the display and output by key operation or external contact.
• Calibration curve correction: Online correction of calibration curve Linear or quadratic correction.
• External setup: Detector No., CH. No., Calibration,Hold or Preset.
• Alarm function:: Outputs contact signal (HCL) beyond
setting-range
• Self-diagnostic: Outputs contact signal(1b) when abnormal condition
With lamp display
• Power supply: 100...240VAC 50/60 Hz
• Power consumption: max. 15 VA
• Working ambient: 0...50 °C
• Casing: ABS
• Protection level IP65
• Mounting: Panel-mount type
• Weight:: Approx. 0.6kg
   
CE STANDARDS SPECIFICATIONS  
• Analog output:: 1x4...20mA
• Load resistance: <500n
• Power supply:: 24VDC±10%
• Power consumption: About 10VA
   
FIBER UNIT  
• Measuring distance and diameter: With lens --- φ25/25mm to φ40/100mm
  Without lens --- φ20/15mm to φ50/50mm
• Długość światłowodów: Standard 1.5m, Max.5m (Reflection type fiber)
  Standard 2m, Max.10m (Transmission type fiber)
• Fiber protection: Stainless steel flexible armour
• Minimum bending radius: r= 100 mm
• Working temperature: 0...150°C
• Purge air flow:: With lens --- Air purge disabled
  Without lens --- 5 to 20L/min
• Accessory:: Vertical mounting holder
  Flange holder

Dimensions [mm]:
Analyzer IRMA
Setting display unit IRGMEG2
Power supply unit IR-WEP
Air purge hood IR-WEA
Output checking plate IR-WEB
Connecting cable IR-WERP
Reflection type fiber
Reflection type fiber (with lens)
IR-WCRE
Transmission type fiber
Output checking plate for
reflection type fiber IR-WCRB
Liquid cell IR-WCC
Air-cooling box IR-WEX