ВАРПРЕН 155 УЛ -10 ° Ц до + 150 ° Ц

Characteristics

• Continuous operating temperatures: -10 °C to +150 °C
• Good resistance to common chemical influences and impregnating varnishes.
• Rated voltage: as per style no.
• Test voltage: 10 x Rated voltage.

Standard products

• Standard insulation colours: white, black, blue, brown, red or yellow/green. 

Approvals - standards

• UL approval as per standard UL 758 - File no.: E101965.
• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965.
• “Horizontal flame test” as per UL approval.
• “FT2 flame rating” as per cUL approval.

Applications

• Class F cabling for electric motors.
• Lights
• Industrial cabling in hot atmospheres up to +150 °C.

Options

• Nickel-plated copper core: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us.
• Other options: contact us.

1 • Flexible bare copper or tin-plated core
2 • Insulation: Varpren®.

 

 
Nominal cross-section  
AWG [mm2] Nominal stranding Avg thickness of insulation (mm) Nominal diameter* (mm)
22 0.34 19 x 0.15 0,76 2.35
- 0.5 19 x 0.18 0,76 2.5
20 0,60 19 x 0,20 0,76 2,6
- 0.75 24 x 0.20 0,76 2.7
18 0.93 19 x 0.25 0,76 2.8
- 1 32 x 0.20 0,76 2.9
16 1.34 19 x 0.30 0,76 3.1
- 1.5 30 x 0.25 0,76 3.15
14 - 19 x 0.37 0.76 3.4
- 2.5 50 x 0.25 0.76 3.6
12 - 37 x 0.34 0.76 4.0
- 4 52 x 0.30 0.76 4.1
10 - 37 x 0.43 0.76 4.7
- 6 84 x 0.30 0.76 4.8
8 - 70 x 0.40 1.14 6.3
- 10 77 x 0.40 1.14 7.0
6 - 105 x 0.40 1.52 8.4
- 16 119 x 0.40 1.52 8.8
4 - 168 x 0.40 1.52 9.8
- 25 196 x 0.40 1.52 10.4
2 35 259 x 0.40 2.04 11.7
1 - 342 x 0.40 2.04 13.6
- 50 370 x 0.40 2.04 14.3
1/0 - 425 x 0.40 2.04 15.0
2/0 70 340 x 0.50 2.04 16.5
3/0 - 434 x 0.50 2.04 17.7
- 95 475 x 0.50 2.04 18.7
4/0 - 546 x 0.50 2.04 19.6
  conducting metal BCDEFG

KEY

Conducting metal
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %



AWM I A     Internal wiring, not subject to mechanical abuse
AWM I A/B   Internal wiring
AWM II A/B   External or Internal wiring
NS   Not Specified
VNS   Voltage Not Specified

Пошаљите упит

Да ли вас занима овај производ? Да ли су вам потребне додатне информације или појединачне цене?

Контактирајте нас

Питајте производ close
Порука је послата.
Питајте производ close
Прегледајте

Додај у листу жеља

морате бити пријављени

Characteristics

• Continuous operating temperatures: -10 °C to +150 °C
• Good resistance to common chemical influences and impregnating varnishes.
• Rated voltage: as per style no.
• Test voltage: 10 x Rated voltage.

Standard products

• Standard insulation colours: white, black, blue, brown, red or yellow/green. 

Approvals - standards

• UL approval as per standard UL 758 - File no.: E101965.
• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965.
• “Horizontal flame test” as per UL approval.
• “FT2 flame rating” as per cUL approval.

Applications

• Class F cabling for electric motors.
• Lights
• Industrial cabling in hot atmospheres up to +150 °C.

Options

• Nickel-plated copper core: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us.
• Other options: contact us.

1 • Flexible bare copper or tin-plated core
2 • Insulation: Varpren®.

 

 
Nominal cross-section  
AWG [mm2] Nominal stranding Avg thickness of insulation (mm) Nominal diameter* (mm)
22 0.34 19 x 0.15 0,76 2.35
- 0.5 19 x 0.18 0,76 2.5
20 0,60 19 x 0,20 0,76 2,6
- 0.75 24 x 0.20 0,76 2.7
18 0.93 19 x 0.25 0,76 2.8
- 1 32 x 0.20 0,76 2.9
16 1.34 19 x 0.30 0,76 3.1
- 1.5 30 x 0.25 0,76 3.15
14 - 19 x 0.37 0.76 3.4
- 2.5 50 x 0.25 0.76 3.6
12 - 37 x 0.34 0.76 4.0
- 4 52 x 0.30 0.76 4.1
10 - 37 x 0.43 0.76 4.7
- 6 84 x 0.30 0.76 4.8
8 - 70 x 0.40 1.14 6.3
- 10 77 x 0.40 1.14 7.0
6 - 105 x 0.40 1.52 8.4
- 16 119 x 0.40 1.52 8.8
4 - 168 x 0.40 1.52 9.8
- 25 196 x 0.40 1.52 10.4
2 35 259 x 0.40 2.04 11.7
1 - 342 x 0.40 2.04 13.6
- 50 370 x 0.40 2.04 14.3
1/0 - 425 x 0.40 2.04 15.0
2/0 70 340 x 0.50 2.04 16.5
3/0 - 434 x 0.50 2.04 17.7
- 95 475 x 0.50 2.04 18.7
4/0 - 546 x 0.50 2.04 19.6
  conducting metal BCDEFG

KEY

Conducting metal
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %



AWM I A     Internal wiring, not subject to mechanical abuse
AWM I A/B   Internal wiring
AWM II A/B   External or Internal wiring
NS   Not Specified
VNS   Voltage Not Specified