EFT-CDN-3100/3200-690 is a high-voltage, high-current coupling/decoupling network for EFT pulse groups, designed for testing AC/DC power pulse groups. It enables automatic three-phase coupling and decoupling.
The maximum load capacity of the EUT (device under test) is:
This is a three-phase, five-wire installation. Other voltage and current values can be customized according to customer requirements.
| Parameter | Value | 
|---|---|
| Model | EFT-CDN-3100/3200-690 | 
| Output Voltage Range | 200V ~ 5000V ±10% | 
| Voltage Resolution | 1V | 
| Voltage Step | 1V | 
| Voltage Accuracy | < ±10% | 
| Output Polarity | +, -, +/-, -/+ | 
| T&H (Temperature and Humidity) | Built-in Thermometer and Hygrometer | 
| Source Impedance | 50Ω | 
| Rise Time | 5ns 30% | 
| Pulse duration | 50ns 30% (50Ω load) 35ns ~ 150ns (1000Ω load) | 
| Frequency range | 0.1kHz ~ 1200kHz | 
| Frequency resolution | 0.1kHz | 
| Standard frequencies | 5kHz, 100kHz | 
| Pulse group duration | 0.001 ~ 2550.000ms | 
| Pulse group period | 300ms (0.15 ~ 99.99s) | 
| Test Duration | 1s ~ 9999s | 
| Direct Output Mode | Via High Voltage Coaxial Connector | 
| Phase Sync | 0° ~ 359° (45Hz ~ 65Hz) (automatic, asynchronous synchronization) | 
| Coupling | Built-in 3-phase, 5-wire coupling | 
| UAC Load | MAX 690V / 200A | 
| UDC Load | MAX 1000V / 200A | 
Érdekel ez a termék? További információra vagy egyedi árajánlatra van szüksége?
Musisz być zalogowany/a
EFT-CDN-3100/3200-690 is a high-voltage, high-current coupling/decoupling network for EFT pulse groups, designed for testing AC/DC power pulse groups. It enables automatic three-phase coupling and decoupling.
The maximum load capacity of the EUT (device under test) is:
This is a three-phase, five-wire installation. Other voltage and current values can be customized according to customer requirements.
| Parameter | Value | 
|---|---|
| Model | EFT-CDN-3100/3200-690 | 
| Output Voltage Range | 200V ~ 5000V ±10% | 
| Voltage Resolution | 1V | 
| Voltage Step | 1V | 
| Voltage Accuracy | < ±10% | 
| Output Polarity | +, -, +/-, -/+ | 
| T&H (Temperature and Humidity) | Built-in Thermometer and Hygrometer | 
| Source Impedance | 50Ω | 
| Rise Time | 5ns 30% | 
| Pulse duration | 50ns 30% (50Ω load) 35ns ~ 150ns (1000Ω load) | 
| Frequency range | 0.1kHz ~ 1200kHz | 
| Frequency resolution | 0.1kHz | 
| Standard frequencies | 5kHz, 100kHz | 
| Pulse group duration | 0.001 ~ 2550.000ms | 
| Pulse group period | 300ms (0.15 ~ 99.99s) | 
| Test Duration | 1s ~ 9999s | 
| Direct Output Mode | Via High Voltage Coaxial Connector | 
| Phase Sync | 0° ~ 359° (45Hz ~ 65Hz) (automatic, asynchronous synchronization) | 
| Coupling | Built-in 3-phase, 5-wire coupling | 
| UAC Load | MAX 690V / 200A | 
| UDC Load | MAX 1000V / 200A | 