The PDRP-10T1 Frequency Drop Generator is a precision test instrument designed to perform AC voltage drop experiments. It is used to test the resistance of electrical and electronic devices to mains voltage fluctuations, providing a common basis for assessing the reliability of the device under test in the event of a mains voltage dip, interruption, or surge.
Parameter | PDRP-10T1 | PDRP-20T1 |
---|---|---|
Voltage Change Range | 0% ~ 120% | 0% ~ 120% |
Duration | 0.5 ~ 6000.0 cycles | 0.5 ~ 6000.0 cycles |
Resolution | 0.5 cycles | 0.5 cycle |
Switching phase setting | 0° ~ 359° or asynchronously | 0° ~ 359° or asynchronously |
Voltage Change Repeat | 1 ~ 60000 cycles | 1 ~ 60000 cycles |
Test Interval | 0.5 ~ 6000.0 cycles | 0.5 ~ 6000.0 cycles |
Resolution | 0.5 cycle | 0.5 cycle |
Trigger mode | Automatic, internal trigger | Automatic, internal trigger |
Coupling load capacity | Single-phase AC 110 ~ 220V | Single-phase AC 110 ~ 220V |
Operating Power Supply | AC 220V 10% 50/60Hz | AC 220V 10% 50/60Hz |
Standard Voltage Drop Values | 0%, 40%, 70%, 80%, 100%, 120% | 0%, 40%, 70%, 80%, 100%, 120% |
Voltage Drop Phase Resolution | 1° | 1° |
Coupling Load Capacity | AC 110 ~ 220V, 10A | AC 110 ~ 220V, 20A |
Érdekel ez a termék? További információra vagy egyedi árajánlatra van szüksége?
Musisz być zalogowany/a
The PDRP-10T1 Frequency Drop Generator is a precision test instrument designed to perform AC voltage drop experiments. It is used to test the resistance of electrical and electronic devices to mains voltage fluctuations, providing a common basis for assessing the reliability of the device under test in the event of a mains voltage dip, interruption, or surge.
Parameter | PDRP-10T1 | PDRP-20T1 |
---|---|---|
Voltage Change Range | 0% ~ 120% | 0% ~ 120% |
Duration | 0.5 ~ 6000.0 cycles | 0.5 ~ 6000.0 cycles |
Resolution | 0.5 cycles | 0.5 cycle |
Switching phase setting | 0° ~ 359° or asynchronously | 0° ~ 359° or asynchronously |
Voltage Change Repeat | 1 ~ 60000 cycles | 1 ~ 60000 cycles |
Test Interval | 0.5 ~ 6000.0 cycles | 0.5 ~ 6000.0 cycles |
Resolution | 0.5 cycle | 0.5 cycle |
Trigger mode | Automatic, internal trigger | Automatic, internal trigger |
Coupling load capacity | Single-phase AC 110 ~ 220V | Single-phase AC 110 ~ 220V |
Operating Power Supply | AC 220V 10% 50/60Hz | AC 220V 10% 50/60Hz |
Standard Voltage Drop Values | 0%, 40%, 70%, 80%, 100%, 120% | 0%, 40%, 70%, 80%, 100%, 120% |
Voltage Drop Phase Resolution | 1° | 1° |
Coupling Load Capacity | AC 110 ~ 220V, 10A | AC 110 ~ 220V, 20A |