| Parameter name | Parameter value | |
|---|---|---|
| Type of SPD | T3 | |
| Mounting | DIN rail 35 mm | |
| Nominal voltage | Un | 230 V AC | 
| Maximum operating voltage | Uc | 275.00 V AC | 
| Nominal load current | IL | 1.000 A | 
| Type of network | TN | |
| Maximum overcurrent protection | 1 A gL/gG or C 1 A | |
| Filter attenuation at 1MHz (50 Ω//50 Ω/) unsymmetrical | 50 dB | |
| Nominal discharge current (8/20 µs) L-N | In | 1.50 kA | 
| Nominal discharge current (8/20 µs) N-PE | In | 1.50 kA | 
| Test voltage L-N | Uoc | 3.0 kV | 
| Test voltage N-PE | Uoc | 3.0 kV | 
| Voltage protection level mode L-N | Up | 1.20 kV | 
| Voltage protection level mode N-PE | Up | 1.20 kV | 
| Response time L-N | ta | 25 ns | 
| Response time N-PE | ta | 100 ns | 
| Cross-section of connected conductors solid (max) | 4.00 mm2 | |
| Cross-section of connected conductors stranded (max) | 2.50 mm2 | |
| Fault indication | supply interruption | |
| Remote indication | no | |
| Degree of protection | IP 20 | |
| Range of ambient temperatures (min/max) | -40 / 80 °C | |
| Humidity | 5 - 95 % | |
| According to standard | EN 61643-11:2012, IEC 61643-11:2011 | |
| ETIM Class | EC000942 | |
| Customs tariff number | 85363010 | |
| EAN | 8595090512059 | 
Sunteți interesat de acest produs? Aveți nevoie de informații suplimentare sau de prețuri individuale?
trebuie să fii logat
| Parameter name | Parameter value | |
|---|---|---|
| Type of SPD | T3 | |
| Mounting | DIN rail 35 mm | |
| Nominal voltage | Un | 230 V AC | 
| Maximum operating voltage | Uc | 275.00 V AC | 
| Nominal load current | IL | 1.000 A | 
| Type of network | TN | |
| Maximum overcurrent protection | 1 A gL/gG or C 1 A | |
| Filter attenuation at 1MHz (50 Ω//50 Ω/) unsymmetrical | 50 dB | |
| Nominal discharge current (8/20 µs) L-N | In | 1.50 kA | 
| Nominal discharge current (8/20 µs) N-PE | In | 1.50 kA | 
| Test voltage L-N | Uoc | 3.0 kV | 
| Test voltage N-PE | Uoc | 3.0 kV | 
| Voltage protection level mode L-N | Up | 1.20 kV | 
| Voltage protection level mode N-PE | Up | 1.20 kV | 
| Response time L-N | ta | 25 ns | 
| Response time N-PE | ta | 100 ns | 
| Cross-section of connected conductors solid (max) | 4.00 mm2 | |
| Cross-section of connected conductors stranded (max) | 2.50 mm2 | |
| Fault indication | supply interruption | |
| Remote indication | no | |
| Degree of protection | IP 20 | |
| Range of ambient temperatures (min/max) | -40 / 80 °C | |
| Humidity | 5 - 95 % | |
| According to standard | EN 61643-11:2012, IEC 61643-11:2011 | |
| ETIM Class | EC000942 | |
| Customs tariff number | 85363010 | |
| EAN | 8595090512059 | 