          Ви повинні увійти в систему
Category
 
         
          Фотографії призначені тільки для інформаційних цілей. Подивитися специфікацію продукту
please use latin characters
Maximal protection, lowest costs
Technical data
 Technical and economical advantages
 - Insulation between primary and secondary winding is not necessary 
 -  Current leakage is closed in the wire
 - Faster winding time
 - Available in small amounts
Construction:
 - Enamel wire copper (magnet wire) (0,2 - 1,0mm, AWG 14-24) + triple insulation according to IEC 60950
 - Other diameters for request
Insulation matersial:
 - ETFE (TEFZEL©)
 - triple insulation according to IEC 60950, Annex C i Annex U
 - UL Certificate e257248
 - Operation voltage max 600vrms
 - Material class "B" 130 oC
 - Break down voltage min 3000v
Application
 - HF transformers
 - HF chokes
 - Impulse power supply
| Diameter | External diameter | Article number | 
|---|---|---|
| 0.20 | 0.40 | 500000002004 | 
| 0.22 | 0.42 | 500000002204 | 
| 0.24 | 0.44 | 500000002404 | 
| 0.25 | 0.45 | 500000002504 | 
| 0.28 | 0.48 | 500000002804 | 
| 0.30 | 0.50 | 500000003004 | 
| 0.32 | 0.52 | 500000003204 | 
| 0.35 | 0.55 | 500000003504 | 
| 0.40 | 0.60 | 500000004004 | 
| 0.45 | 0.65 | 500000004504 | 
| 0.50 | 0.70 | 500000005004 | 
| 0.55 | 0.75 | 500000005504 | 
| 0.60 | 0.80 | 500000006004 | 
| 0.70 | 0.90 | 500000007004 | 
| 0.80 | 1.00 | 500000008004 | 
| 0.90 | 1.10 | 500000009004 | 
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
Maximal protection, lowest costs
Technical data
 Technical and economical advantages
 - Insulation between primary and secondary winding is not necessary 
 -  Current leakage is closed in the wire
 - Faster winding time
 - Available in small amounts
Construction:
 - Enamel wire copper (magnet wire) (0,2 - 1,0mm, AWG 14-24) + triple insulation according to IEC 60950
 - Other diameters for request
Insulation matersial:
 - ETFE (TEFZEL©)
 - triple insulation according to IEC 60950, Annex C i Annex U
 - UL Certificate e257248
 - Operation voltage max 600vrms
 - Material class "B" 130 oC
 - Break down voltage min 3000v
Application
 - HF transformers
 - HF chokes
 - Impulse power supply
| Diameter | External diameter | Article number | 
|---|---|---|
| 0.20 | 0.40 | 500000002004 | 
| 0.22 | 0.42 | 500000002204 | 
| 0.24 | 0.44 | 500000002404 | 
| 0.25 | 0.45 | 500000002504 | 
| 0.28 | 0.48 | 500000002804 | 
| 0.30 | 0.50 | 500000003004 | 
| 0.32 | 0.52 | 500000003204 | 
| 0.35 | 0.55 | 500000003504 | 
| 0.40 | 0.60 | 500000004004 | 
| 0.45 | 0.65 | 500000004504 | 
| 0.50 | 0.70 | 500000005004 | 
| 0.55 | 0.75 | 500000005504 | 
| 0.60 | 0.80 | 500000006004 | 
| 0.70 | 0.90 | 500000007004 | 
| 0.80 | 1.00 | 500000008004 | 
| 0.90 | 1.10 | 500000009004 | 
Вашу оцінку відгуку не було надіслано
Поскаржитись на відгук
Скаргу надіслано
Ваш відгук не надіслано
Написати свій відгук
Відгук надіслано
Ваш відгук не надіслано