          Ви повинні увійти в систему
Category
 
         
               
               
               
               
              Фотографії призначені тільки для інформаційних цілей. Подивитися специфікацію продукту
please use latin characters
Zone 0
Factory-set pressure switch monitoring overpressure, vacuum or differential pressure of liquid and gaseous – also aggressive – media.
Pressure setting and switching differential are factory-set by the manufacturer.
Specifications:
| Medium | Air, (non-)combustible and aggressive gases and vapours | 
| Temperature ranges: | |
| Medium and ambient temperature | -20OC +85OC | 
| Storage temperature | -40OC +85OC | 
| Trip pressure ranges: | |
| Overpressure | 5 to 200 mbar (min. measuring range | 
| 1 to 12 bar (max. measuring range) | |
| Vacuum | -5 to -200 mbar (min. measuring range) | 
| -200 to -900 mbar (max. measuring range) | |
| Differential pressure | 5 ... 50 mbar | 
| Max. working overpressure | 0.1 to 25 bar/-1 bar (refer to table | 
| Switching differential | 2.5 to 1,500 mbar; depending on pressure range (refer to table) | 
| Trip pressure tolerance | ±10% from setpoint | 
| Materials | |
| Tube connection | 5 / 6.5 and 10 mm, PA / PPS | 
| Threaded connections | M10x1 / G1/8 to G1/2 | 
| PA/PVDF/stainless steel/brass | |
| Diaphragm | depending on medium; NBR, silicone, FKM (Viton ® ), EPDM, for 901.30 silicone (other materials on request). | 
| Weight | 24 VDC/100 mA; 30 VDC/45 mA | 
| Electrical rating | 24VDC/100mA; 30VDC/45mA | 
| Electrical connection | AMP flat plug, 6.3 mm x 0.8 mm, in accordance with DIN 46244, or push-on screw terminals | 
| Cable conduit | M16x1.5, with integrated cable strain relief | 
| Protection category | IP 54 (with cover 6371) | 
| Mechanical working life | over 106 switching operations | 
| Reducing nozzles | diameter optionally 0.3/0.5/0.8 mm | 
ATEX
| EC type examination | BVS 06 ATEX E 141X | 
| Device category | I 1/2G or II 2G | 
| Ignition protection type | EX ia IIBT4 or EX ia IICT4 | 
| CE conformity | ATEX Directive 94/9/EC | 
| RoHS-Directive 2002/95/EC | |
| Other approvals | type examination by TÜV Südwest and DVGW | 

| for 901.1x EX, 901.30 EX, 901.41 EX, 901.51 EX | only for 901.2x EX | 
|  |  | 
| Type | Tube connections | Threaded connections | |||||
|---|---|---|---|---|---|---|---|
| 5,0 mm | 6,5 mm | 10,0 mm | M10x1 | G1/8 | G1/4 | G1/2 | |
| 901.1x EX | PA | PA PPS | PA PPS | PA, PVDF, MS, V2A | PA, PVDF, MS, V2A | PVDF, MS, V2A | MS | 
| 901.2x EX | PA | PA PPS | PA PPS | PA, PVDF, MS, V2A | PA, PVDF, MS, V2A | MS, V2A | MS | 
| 901.30 EX | PA | ||||||
| 901.41 EX | PA PPS | PA PPS | PA, PVDF, MS, V2A | PA, PVDF, MS, V2A | MS, V2A | MS | |
| 901.51 EX | MS | MS, V2A | MS, V2A | ||||
PA = polyamide, PVDF = polyvinyldifluoride, PPS = polyphenylensulfide, MS = brass
| Type | Factory-set trip pressure selectable | Standard switching differential | Tolerance band in % of trip pressure | Maximum positive working pressure | Maximum negative working pressure | ||
|---|---|---|---|---|---|---|---|
| between | and | lower end of range | upper end of range | ||||
| 901.1x EX | 5 | 200 mbar | 2,5 mbar | 50 mbar | 10% | 0,5 / 4 bar | -/ -1 bar | 
| 200 | 1000 mbar | 50 mbar | 150 mbar | 10% | 1 / 4 bar | -/ -1 bar | |
| 901.41 EX | 500 | 3000 mbar | 200 mbar | 600 mbar | 10% | 10 bar | -1 bar | 
| 901.51 EX | 1,0 bar | 12 bar | 0,2 bar | 1,5 bar | 10% | 25 bar | -1 bar | 
| Type | Factory-set trip pressure selectable | Standard switching differential | Tolerance band in % of trip pressure | Maximum positive working pressure | Maximum negative working pressure | ||
|---|---|---|---|---|---|---|---|
| between | and | lower end of range | upper end of range | ||||
| 901.2x EX | -5 | -200 mbar | 2,5 mbar | 50 mbar | 10% | 0,5 / 4 bar | -1 bar | 
| -200 | -900 mbar | 50 mbar | 150 mbar | 10% | 1 / 4 bar | -1 bar | |
| Type | Factory-set trip pressure selectable | Standard switching differential | Tolerance band in % of trip pressure | Maximum positive working pressure | Maximum negative working pressure | ||
|---|---|---|---|---|---|---|---|
| between | and | lower end of range | upper end of range | ||||
| 901.30 | 5 mbar | 50 mbar | 2,5 mbar | 25 mbar | 10% | 100 mbar | -100 mbar | 

Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
Zone 0
Factory-set pressure switch monitoring overpressure, vacuum or differential pressure of liquid and gaseous – also aggressive – media.
Pressure setting and switching differential are factory-set by the manufacturer.
Specifications:
| Medium | Air, (non-)combustible and aggressive gases and vapours | 
| Temperature ranges: | |
| Medium and ambient temperature | -20OC +85OC | 
| Storage temperature | -40OC +85OC | 
| Trip pressure ranges: | |
| Overpressure | 5 to 200 mbar (min. measuring range | 
| 1 to 12 bar (max. measuring range) | |
| Vacuum | -5 to -200 mbar (min. measuring range) | 
| -200 to -900 mbar (max. measuring range) | |
| Differential pressure | 5 ... 50 mbar | 
| Max. working overpressure | 0.1 to 25 bar/-1 bar (refer to table | 
| Switching differential | 2.5 to 1,500 mbar; depending on pressure range (refer to table) | 
| Trip pressure tolerance | ±10% from setpoint | 
| Materials | |
| Tube connection | 5 / 6.5 and 10 mm, PA / PPS | 
| Threaded connections | M10x1 / G1/8 to G1/2 | 
| PA/PVDF/stainless steel/brass | |
| Diaphragm | depending on medium; NBR, silicone, FKM (Viton ® ), EPDM, for 901.30 silicone (other materials on request). | 
| Weight | 24 VDC/100 mA; 30 VDC/45 mA | 
| Electrical rating | 24VDC/100mA; 30VDC/45mA | 
| Electrical connection | AMP flat plug, 6.3 mm x 0.8 mm, in accordance with DIN 46244, or push-on screw terminals | 
| Cable conduit | M16x1.5, with integrated cable strain relief | 
| Protection category | IP 54 (with cover 6371) | 
| Mechanical working life | over 106 switching operations | 
| Reducing nozzles | diameter optionally 0.3/0.5/0.8 mm | 
ATEX
| EC type examination | BVS 06 ATEX E 141X | 
| Device category | I 1/2G or II 2G | 
| Ignition protection type | EX ia IIBT4 or EX ia IICT4 | 
| CE conformity | ATEX Directive 94/9/EC | 
| RoHS-Directive 2002/95/EC | |
| Other approvals | type examination by TÜV Südwest and DVGW | 

| for 901.1x EX, 901.30 EX, 901.41 EX, 901.51 EX | only for 901.2x EX | 
|  |  | 
| Type | Tube connections | Threaded connections | |||||
|---|---|---|---|---|---|---|---|
| 5,0 mm | 6,5 mm | 10,0 mm | M10x1 | G1/8 | G1/4 | G1/2 | |
| 901.1x EX | PA | PA PPS | PA PPS | PA, PVDF, MS, V2A | PA, PVDF, MS, V2A | PVDF, MS, V2A | MS | 
| 901.2x EX | PA | PA PPS | PA PPS | PA, PVDF, MS, V2A | PA, PVDF, MS, V2A | MS, V2A | MS | 
| 901.30 EX | PA | ||||||
| 901.41 EX | PA PPS | PA PPS | PA, PVDF, MS, V2A | PA, PVDF, MS, V2A | MS, V2A | MS | |
| 901.51 EX | MS | MS, V2A | MS, V2A | ||||
PA = polyamide, PVDF = polyvinyldifluoride, PPS = polyphenylensulfide, MS = brass
| Type | Factory-set trip pressure selectable | Standard switching differential | Tolerance band in % of trip pressure | Maximum positive working pressure | Maximum negative working pressure | ||
|---|---|---|---|---|---|---|---|
| between | and | lower end of range | upper end of range | ||||
| 901.1x EX | 5 | 200 mbar | 2,5 mbar | 50 mbar | 10% | 0,5 / 4 bar | -/ -1 bar | 
| 200 | 1000 mbar | 50 mbar | 150 mbar | 10% | 1 / 4 bar | -/ -1 bar | |
| 901.41 EX | 500 | 3000 mbar | 200 mbar | 600 mbar | 10% | 10 bar | -1 bar | 
| 901.51 EX | 1,0 bar | 12 bar | 0,2 bar | 1,5 bar | 10% | 25 bar | -1 bar | 
| Type | Factory-set trip pressure selectable | Standard switching differential | Tolerance band in % of trip pressure | Maximum positive working pressure | Maximum negative working pressure | ||
|---|---|---|---|---|---|---|---|
| between | and | lower end of range | upper end of range | ||||
| 901.2x EX | -5 | -200 mbar | 2,5 mbar | 50 mbar | 10% | 0,5 / 4 bar | -1 bar | 
| -200 | -900 mbar | 50 mbar | 150 mbar | 10% | 1 / 4 bar | -1 bar | |
| Type | Factory-set trip pressure selectable | Standard switching differential | Tolerance band in % of trip pressure | Maximum positive working pressure | Maximum negative working pressure | ||
|---|---|---|---|---|---|---|---|
| between | and | lower end of range | upper end of range | ||||
| 901.30 | 5 mbar | 50 mbar | 2,5 mbar | 25 mbar | 10% | 100 mbar | -100 mbar | 

Вашу оцінку відгуку не було надіслано
Поскаржитись на відгук
Скаргу надіслано
Ваш відгук не надіслано
Написати свій відгук
Відгук надіслано
Ваш відгук не надіслано