Diodo - tiristoriaus modulis – M1C..P
  • Diodo - tiristoriaus modulis – M1C..P

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: DACPOL

Diodo - tiristoriaus modulis – M1C..P

One element power diode-thyrisor block with radiator RY.RY.

Properties:

• Two element power diode-thyristor block with both side cooling– RY
• Natural cooling

Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts

Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling

Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Scheme


Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature -100 C - +400 C;
• Atmospheric pressure  860hPa - 1060hPa
• Humidity less then 80% @ temperature 40 C
• Cooling air without aggressive factors. .

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight 
[kg]

M1C7P

450…650 400…2400 7000…10000 6,9

M1C8P

630…1000 400…8500 10000…24000 6,9

M1C9P

1000…2000 400…7500 20000…42000 16,4

M1C11P

1000…3200 400…6000 27000…65000 18,3

 
Power block scheme M1C...P
 

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

One element power diode-thyrisor block with radiator RY.RY.

Properties:

• Two element power diode-thyristor block with both side cooling– RY
• Natural cooling

Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts

Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling

Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Scheme


Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature -100 C - +400 C;
• Atmospheric pressure  860hPa - 1060hPa
• Humidity less then 80% @ temperature 40 C
• Cooling air without aggressive factors. .

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight 
[kg]

M1C7P

450…650 400…2400 7000…10000 6,9

M1C8P

630…1000 400…8500 10000…24000 6,9

M1C9P

1000…2000 400…7500 20000…42000 16,4

M1C11P

1000…3200 400…6000 27000…65000 18,3

 
Power block scheme M1C...P