Dviejų tiristorių modulis – M2C..W
  • Dviejų tiristorių modulis – M2C..W

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: DACPOL

Dviejų tiristorių modulis – M2C..W

Double thyristor module with water radiator

Properties:
• Double thyristor module with water radiator
• water cooling

Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts

Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling

Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.

Drawing 1
Scheme


Operation conditions:
Two element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C with ambient air temperature >-100 C
• Atmospheric pressure 860hPa do 1060hPa

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight
[kg]
M2C7W 450…650 400…2400 7000…10000 3,2
M2C8W 630…1000 400…8500 10000…24000 3,6
M2C9W 1000…2000 400…7500 20000…42000 6,9
M2C11W 1000…3200 400…6000 27000…65000 19,0

 
Power block scheme M2C..W

 

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

Double thyristor module with water radiator

Properties:
• Double thyristor module with water radiator
• water cooling

Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts

Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling

Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.

Drawing 1
Scheme


Operation conditions:
Two element power blocks are used in power electronic systems.
• cooling water temperature 50 C - 300 C with ambient air temperature >-100 C
• Atmospheric pressure 860hPa do 1060hPa

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight
[kg]
M2C7W 450…650 400…2400 7000…10000 3,2
M2C8W 630…1000 400…8500 10000…24000 3,6
M2C9W 1000…2000 400…7500 20000…42000 6,9
M2C11W 1000…3200 400…6000 27000…65000 19,0

 
Power block scheme M2C..W