MCI soft starteriai - minkšto paleidimo ir stabdymo sistemos
  • MCI soft starteriai - minkšto paleidimo ir stabdymo sistemos

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: Danfoss

MCI soft starteriai - minkšto paleidimo ir stabdymo sistemos

MCI soft starts are verified solutions for 3 phase asynchronous motors start up.They keep start up currents on reasonable level, which allow to elongate the non failure operation of machine.
They are perfect solutions for application where there are many  soft start cycles.
They can be used with pumps and ventilators, feeders, transporters.  Because of set up start torque and unique function (kick start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start ups and stops, which make production lines more reliable. Also start up currents reduction lowers voltage drops on light mains.

 

Properties
- Unlimited turn ons per hour
- start up time set up
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-30 s, MCI 40-3D I-O; MCI 50 I-O
- coasting time set up:
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-60 s, MCI 40-3D I-O; MCI 50 I-O
- set up starting toque up to 85 %
- static friction forcing (kick start)
- universal control voltage 24-480V ac/dc
- maximum operation voltage up to 600 V Ac
- Control in three phases - some models
- Automatic phase decay detection
- Automatic adaptation to 50/60 Hz
- LED operation indicator
- build in protection varistor
- optional additional contacts
- easy and quick assembly
- compact construction with radiator
- DIN assembled
- standards EN 60947-4-2
- Certificates CE and UL (UL 508)

Type Operation voltage
V ac
motor power motor current Width
L
[mm]1)
Additional contacts Catalogue number
MCI 3 380 - 415 1,5kW 3 A 22,5 - 037N0074
MCI 3 440 - 480 1,5kW 3 A 22,5 - 037N0084
MCI 15BP 400 - 415 7,5kW2) 15 A2) 45 - 037N0139
MCI 15 380 - 480 7,5kW 15 A 45 - 037N0039
MCI 25 380 - 480 IlkW 25 A 90 - 037N0040
MCI 30 380 - 480 15kW3) 25/303) A 90 IO/bypass 037N0070
MCI 40-3D IO 380 - 480 21kW4) 29/433) A 90 IO/bypass 037N0092
MCI 50-3 10 380 - 480 22kW3) 35/503) A 180 IO/bypass 037N0090
MCI 50-3 10 380 - 480 45kW4) 863) A 180 IO/bypass 037N0090
MCI 3 500 - 600 2,2kW 3 A 22,5 - 037N0075
MCI 15 500 - 600 7,5kW 15 A 45 - 037N0041
MCI 25 500 - 600 15kW 25 90 - 037N0042
MCI 30 500 - 600 18,5kW3) 25/303) A 90 IO/bypass 037N0071
MCI 50-3 10 500 - 600 30kW3) 35/503) A ISO IO/bypass 037N0091

1)DIN width assembly
2)Needed down time between soft starts for 15A is 110s, 12A(100s), 9A(95s)
3)with by-pass
4)only in internal triangle circuit.

Dimensions


Operation rule


During start up soft starts rises linearly motor supplying voltage up to nominal value. Motor speed depends on the load torque. Time is independent from frequency or load. In hardest situations kick start function can be used.

Fuse protection

  MCI 3 MCI15BP MCI 15 MCi 25 MCI 30 MCI 40 MCI 50
Typ 1 gL/gG 25 A 50 A 50 A 80 A 125 A
Typ 2I2t 72 1800 1800 6300 25300

Connection scheme

MCI 15, MCI25 MCI 30 I-O MCI 50-3 I-O

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

MCI soft starts are verified solutions for 3 phase asynchronous motors start up.They keep start up currents on reasonable level, which allow to elongate the non failure operation of machine.
They are perfect solutions for application where there are many  soft start cycles.
They can be used with pumps and ventilators, feeders, transporters.  Because of set up start torque and unique function (kick start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start ups and stops, which make production lines more reliable. Also start up currents reduction lowers voltage drops on light mains.

 

Properties
- Unlimited turn ons per hour
- start up time set up
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-30 s, MCI 40-3D I-O; MCI 50 I-O
- coasting time set up:
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-60 s, MCI 40-3D I-O; MCI 50 I-O
- set up starting toque up to 85 %
- static friction forcing (kick start)
- universal control voltage 24-480V ac/dc
- maximum operation voltage up to 600 V Ac
- Control in three phases - some models
- Automatic phase decay detection
- Automatic adaptation to 50/60 Hz
- LED operation indicator
- build in protection varistor
- optional additional contacts
- easy and quick assembly
- compact construction with radiator
- DIN assembled
- standards EN 60947-4-2
- Certificates CE and UL (UL 508)

Type Operation voltage
V ac
motor power motor current Width
L
[mm]1)
Additional contacts Catalogue number
MCI 3 380 - 415 1,5kW 3 A 22,5 - 037N0074
MCI 3 440 - 480 1,5kW 3 A 22,5 - 037N0084
MCI 15BP 400 - 415 7,5kW2) 15 A2) 45 - 037N0139
MCI 15 380 - 480 7,5kW 15 A 45 - 037N0039
MCI 25 380 - 480 IlkW 25 A 90 - 037N0040
MCI 30 380 - 480 15kW3) 25/303) A 90 IO/bypass 037N0070
MCI 40-3D IO 380 - 480 21kW4) 29/433) A 90 IO/bypass 037N0092
MCI 50-3 10 380 - 480 22kW3) 35/503) A 180 IO/bypass 037N0090
MCI 50-3 10 380 - 480 45kW4) 863) A 180 IO/bypass 037N0090
MCI 3 500 - 600 2,2kW 3 A 22,5 - 037N0075
MCI 15 500 - 600 7,5kW 15 A 45 - 037N0041
MCI 25 500 - 600 15kW 25 90 - 037N0042
MCI 30 500 - 600 18,5kW3) 25/303) A 90 IO/bypass 037N0071
MCI 50-3 10 500 - 600 30kW3) 35/503) A ISO IO/bypass 037N0091

1)DIN width assembly
2)Needed down time between soft starts for 15A is 110s, 12A(100s), 9A(95s)
3)with by-pass
4)only in internal triangle circuit.

Dimensions


Operation rule


During start up soft starts rises linearly motor supplying voltage up to nominal value. Motor speed depends on the load torque. Time is independent from frequency or load. In hardest situations kick start function can be used.

Fuse protection

  MCI 3 MCI15BP MCI 15 MCi 25 MCI 30 MCI 40 MCI 50
Typ 1 gL/gG 25 A 50 A 50 A 80 A 125 A
Typ 2I2t 72 1800 1800 6300 25300

Connection scheme

MCI 15, MCI25 MCI 30 I-O MCI 50-3 I-O