shopping_cart
Krepšelis
0,00 PLN
0
Iškarpinė
Jūs turite būti prisijungę
Menu
-
sugrįžtiX
-
Visos kategorijos
-
-
Category
-
Puslaidininkiai
- Diodai
- Tiristoriai
-
Elektroizoliuoti moduliai
- Elektrai izoliuoti moduliai | VISHAY (IR)
- Elektrai izoliuoti moduliai | INFINEON (EUPEC)
- Elektrai izoliuoti moduliai | Semikronas
- Elektrai izoliuoti moduliai | POWEREX
- Elektrai izoliuoti moduliai | IXYS
- Elektrai izoliuoti moduliai | POSEICO
- Elektrai izoliuoti moduliai | ABB
- Elektrai izoliuoti moduliai | TECHSEM
- Eikite į subkategoriją
- Lygintuviniai tilteliai
-
Tranzistoriai
- Tranzistoriai | GeneSiC
- SiC MOSFET moduliai | Mitsubishi
- SiC MOSFET moduliai | STARPOWER
- „ABB SiC MOSFET“ moduliai
- IGBT moduliai | MITSUBISHI
- Tranzistorių moduliai | MITSUBISHI
- MOSFET moduliai | MITSUBISHI
- Tranzistorių moduliai | ABB
- IGBT moduliai POWEREX
- IGBT moduliai INFINEON (EUPEC)
- Silicio karbido puslaidininkiniai elementai
- Eikite į subkategoriją
- Valdikliai
- Galios blokai
- Eikite į subkategoriją
-
Elektrinių dydžių keitikliai
-
Dabartiniai keitikliai | LEM
- Srovės keitiklis su uždara atbulinio ryšio kilpa (C/L)
- Srovės keitiklis su atvira atbulinio ryšio kilpa (O/L)
- Vienpolės maitinimo įtampos srovės keitiklis
- Eta technologijos keitikliai
- Didelio tikslumo srovės keitikliai LF xx10 serija
- LH serijos srovės keitikliai
- HOYS ir HOYL - skirti montuoti tiesiai ant laidininko bėgio
- Dabartiniai „GO-SME“ ir „GO-SMS“ serijos SMD technologijos keitikliai
- AUTOMOBILIŲ srovės keitikliai
- Eikite į subkategoriją
-
Įtampos keitikliai | LEM
- LV serijos įtampos keitikliai
- DVL serijos įtampos keitikliai
- CV serijos tikslūs įtampos keitikliai su dviguba magnetine šerdimi CV serijos
- Įtampos keitiklis geležinkeliams DV 4200/SP4
- DVM serijos įtampos keitikliai
- Įtampos keitiklis - DVC 1000-P
- Įtampos keitikliai - DVC 1000 serija
- Eikite į subkategoriją
- Apsaugos, stebėjimo ir kontrolės keitikliai | LEM
- Dviejų branduolių keitikliai | LEM
- Tikslieji srovės keitikliai | LEM
- Eikite į subkategoriją
-
Dabartiniai keitikliai | LEM
-
Pasyvūs komponentai (kondensatoriai, rezistoriai, saugikliai, filtrai)
- Rezistoriai
-
Saugikliai
- ABC ir AGC serijos miniatiūriniai saugikliai elektronikai
- Greitaeigiai cilindriniai saugikliai
- Uždelsimo elementai su GL/GG ir AM charakteristikomis
- Ultragreiti intarpai - saugikliai
- Didžiosios Britanijos ir JAV standartų greitaeigiai saugikliai
- Europos standarto greitaeigiai saugikliai
- Saugikliai geležinkeliui
- Aukštos įtampos saugikliai
- Eikite į subkategoriją
-
Kondensatoriai
- Kondensatoriai varikliams
- Elektrolitiniai kondensatoriai
- Snubbers tipo kondensatoriai
- Galios kondensatoriai
- Kondensatoriai DC grandinėms
- Kondensatoriai galios kompensavimui
- Aukštos įtampos kondensatoriai
- Kondensatoriai indukciniam kaitinimui
- Impulsiniai ir energijos kaupimo kondensatoriai
- DC LINK kondensatoriai
- AC / DC grandinių kondensatoriai
- Eikite į subkategoriją
- Slopinimo tinklo filtrai
- Superkondensatoriai
- Apsauga nuo viršįtampių
- Eikite į subkategoriją
-
Relės ir kontaktoriai
- Relių ir kontaktorių teorija
- Trijų fazių puslaidininkinės AC relės
- Puslaidininkinės DC relės
- Reguliatoriai, valdikliai ir jų priedai
- Soft starteriai (minkšto paleidimo įrenginiai) bei reversiniai kontaktoriai
- Elektromechaninės relės
- Kontaktoriai
- Rotaciniai jungikliai
-
Vienos fazės puslaidininkinės AC relės
- AC vienfazės puslaidininkinės relės 1 | D2425 | D2450 serijų
- AC vienfazės puslaidininkinės relės CWA ir CWD serijų
- AC vienfazės puslaidininkinės relės CMRA ir CMRD serijų
- AC vienfazės puslaidininkinės relės PS serijos
- AC puslaidininkinės dvigubos ir keturgubos relės D24 D, TD24 Q, H12D48 D serijų
- Vienfazės puslaidininkinės relės gn serijos
- AC vienfazės puslaidininkinės relės CKR serijos
- AC vienfazės relės DIN bėgiams ERDA ir ERAA serijų
- Vienfazės kintamosios srovės relės, skirtos 150A srovei
- Dvigubos kietojo kūno relės, integruotos su radiatoriumi DIN bėgiui
- Eikite į subkategoriją
- Vienos fazės puslaidininkinės AC relės spausdinimo plokštėms
- Interfejsų relės
- Eikite į subkategoriją
- Indukciniai elementai
- Radiatoriai, varistoriai, termo apsauga
- Ventiliatoriai
- Kondicioneriai, elektros spintų aksesuarai, aušintuvai
-
Baterijos, įkrovikliai, buferiniai maitinimo šaltiniai ir keitikliai
- Baterijos, įkrovikliai - teorinis aprašymas
- Ličio jonų baterijos. Individualios baterijos. Baterijų valdymo sistema (BMS)
-
Akumuliatoriai
- Panasonic įmonės akumuliatoriai
- SSB įmonės akumuliatoriai
- Sonnenschein Dryfit įmonės akumuliatoriai
- MK Battery įmonės geliniai akumuliatoriai
- FIAMM įmonės akumuliatoriai
- Victron Energy akumuliatoriai
- „Victron Energy LiFePO4“ akumuliatoriai
- „Dyno“ baterijos
- APC UPS RBC akumuliatorių paketai
- Eikite į subkategoriją
- Akumuliatorių įkrovikliai ir priedai
- UPS atsarginis maitinimo šaltinis ir buferiniai maitinimo šaltiniai
- Fotoelektros keitikliai ir priedai
- Energijos kaupimas
- Kuro elementai
- Ląstelės litio-joninės
- Eikite į subkategoriją
-
Automatikos komponentai
- Galiniai jungikliai, mikrojungikliai
- Jutikliai, keitikliai
- Pirometrai
- Skaitikliai, laiko relės, paneliniai matuokliai
- Pramoniniai apsaugos įrenginiai
- Šviesos ir garso signalizacija
- Terminio vaizdo kamera
- LED švieslentės
- Valdymo aparatūra - mygtukai ir jungikliai
-
Registravimo prietaisai
- AL3000 - įrašantis į juostą temperatūros registratorius su skaitmeniniu ekranu
- Mikroprocesoriniai registratoriai su LCD ekranu KR2000 serijos
- Registratorius KR5000
- Matuoklis su drėgmės ir temperatūros įrašymo funkcija HN-CH
- Registratorių reikmenys
- Grafinis kompaktinis registratorius 71VR1
- Registratorius KR 3000
- PC registratoriai R1M serijos
- PC registratoriai R2M serijos
- PC registratorius, 12 izoliuotų įėjimų – RZMS
- PC registratorius, USB, 12 izoliuotų įėjimų – RZUS
- Eikite į subkategoriją
- Valdikliai
- Eikite į subkategoriją
-
Laidai, pynės, laidų apsauginės žarnos, lankstūs sujungimai
- Laidai
- Daugiagisliai laidai
-
Kabeliai ekstremalioms sąlygoms
- Kompensaciniai ir prailginimo kabeliai
- Laidai termoporoms
- PT jutikliams prijungimo laidai
- Daugiagysliai laidai temp. -60C iki +1400C
- Vidutinės įtampos kabeliai
- Uždegimo laidai
- Šildymo laidai
- Viengysliai laidai temp. -60C iki +450C
- Geležinkelio kabeliai
- Šildymo kabeliai Ex zonoms
- Eikite į subkategoriją
- Apsaugos vamzdeliai
-
Pintinės
- Plokščios pintinės
- Apvalios pintinės
- Plokščios labai elastingos pintinės
- Apvalios labai elastingos pintinės
- Cilindro formos vario pintinės
- Vario cilindrinės pintinės su apsauga
- Elastingos įžeminimo juostos
- Cinkuoto ir nerūdijančio plieno cilindrinės pintinės
- PCV izoliuotos vario pintinės - temperatūra iki 85 C
- Plokščios aliuminio pintinės
- Sujungimo komplektas - pintinės ir vamzdeliai
- Eikite į subkategoriją
- Aksesuarai geležinkeliams
- Kabelių antgaliai
- Lanksčios izoliuotos šynos
- Daugiasluoksnės lanksčios šynos
- Laidų pravedimo sistemos (PESZLE)
- Gofruotos apsauginės žarnos
- Eikite į subkategoriją
- Žiūrėti visas kategorijas
-
Puslaidininkiai
-
-
- Tiekėjai
-
Pritaikymų sąrašas
- CNC staklės
- Energetika
- Indukcinis kaitinimas
- Įranga ir komponentai sprogimo pavojaus zonoms (Ex)
- Kasyklos, metalurgijos ir liejimo pramonė
- Laboratoriniai ir moksliniai matavimai
- Maitinimo šaltiniai (UPS) ir lygintuvinės sistemos
- Medienos džiovinimo ir apdirbimo mašinos
- Nuolatinės ir kintamos srovės pavaros (keitikliai)
- Paskirstymo, valdymo ir telekomunikacijos spintų įranga
- Plastmasių liejimo mašinos
- Poligrafija
- Pramoninė apsaugos įranga
- Pramoninė automatika
- Suvirinimo aparatai
- ŠVOK automatika
- Temperatūros matavimas ir nustatymas
- Tramvajų ir traukinių pavaros
- Varikliai ir transformatoriai
-
PASLAUGOS, REMONTAS
-
-
Įrangos montavimas
-
- Kontaktai
- Zobacz wszystkie kategorie
Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją
please use latin characters
MCI soft starts are verified solutions for 3 phase asynchronous motors start up.They keep start up currents on reasonable level, which allow to elongate the non failure operation of machine.
They are perfect solutions for application where there are many soft start cycles.
They can be used with pumps and ventilators, feeders, transporters. Because of set up start torque and unique function (kick start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start ups and stops, which make production lines more reliable. Also start up currents reduction lowers voltage drops on light mains.
- Unlimited turn ons per hour
- start up time set up
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-30 s, MCI 40-3D I-O; MCI 50 I-O
- coasting time set up:
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-60 s, MCI 40-3D I-O; MCI 50 I-O
- set up starting toque up to 85 %
- static friction forcing (kick start)
- universal control voltage 24-480V ac/dc
- maximum operation voltage up to 600 V Ac
- Control in three phases - some models
- Automatic phase decay detection
- Automatic adaptation to 50/60 Hz
- LED operation indicator
- build in protection varistor
- optional additional contacts
- easy and quick assembly
- compact construction with radiator
- DIN assembled
- standards EN 60947-4-2
- Certificates CE and UL (UL 508)
1)DIN width assembly
2)Needed down time between soft starts for 15A is 110s, 12A(100s), 9A(95s)
3)with by-pass
4)only in internal triangle circuit.
During start up soft starts rises linearly motor supplying voltage up to nominal value. Motor speed depends on the load torque. Time is independent from frequency or load. In hardest situations kick start function can be used.
They are perfect solutions for application where there are many soft start cycles.
They can be used with pumps and ventilators, feeders, transporters. Because of set up start torque and unique function (kick start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start ups and stops, which make production lines more reliable. Also start up currents reduction lowers voltage drops on light mains.
Properties
- Unlimited turn ons per hour
- start up time set up
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-30 s, MCI 40-3D I-O; MCI 50 I-O
- coasting time set up:
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-60 s, MCI 40-3D I-O; MCI 50 I-O
- set up starting toque up to 85 %
- static friction forcing (kick start)
- universal control voltage 24-480V ac/dc
- maximum operation voltage up to 600 V Ac
- Control in three phases - some models
- Automatic phase decay detection
- Automatic adaptation to 50/60 Hz
- LED operation indicator
- build in protection varistor
- optional additional contacts
- easy and quick assembly
- compact construction with radiator
- DIN assembled
- standards EN 60947-4-2
- Certificates CE and UL (UL 508)
Type | Operation voltage V ac |
motor power | motor current | Width L [mm]1) |
Additional contacts | Catalogue number |
---|---|---|---|---|---|---|
MCI 3 | 380 - 415 | 1,5kW | 3 A | 22,5 | - | 037N0074 |
MCI 3 | 440 - 480 | 1,5kW | 3 A | 22,5 | - | 037N0084 |
MCI 15BP | 400 - 415 | 7,5kW2) | 15 A2) | 45 | - | 037N0139 |
MCI 15 | 380 - 480 | 7,5kW | 15 A | 45 | - | 037N0039 |
MCI 25 | 380 - 480 | IlkW | 25 A | 90 | - | 037N0040 |
MCI 30 | 380 - 480 | 15kW3) | 25/303) A | 90 | IO/bypass | 037N0070 |
MCI 40-3D IO | 380 - 480 | 21kW4) | 29/433) A | 90 | IO/bypass | 037N0092 |
MCI 50-3 10 | 380 - 480 | 22kW3) | 35/503) A | 180 | IO/bypass | 037N0090 |
MCI 50-3 10 | 380 - 480 | 45kW4) | 863) A | 180 | IO/bypass | 037N0090 |
MCI 3 | 500 - 600 | 2,2kW | 3 A | 22,5 | - | 037N0075 |
MCI 15 | 500 - 600 | 7,5kW | 15 A | 45 | - | 037N0041 |
MCI 25 | 500 - 600 | 15kW | 25 | 90 | - | 037N0042 |
MCI 30 | 500 - 600 | 18,5kW3) | 25/303) A | 90 | IO/bypass | 037N0071 |
MCI 50-3 10 | 500 - 600 | 30kW3) | 35/503) A | ISO | IO/bypass | 037N0091 |
1)DIN width assembly
2)Needed down time between soft starts for 15A is 110s, 12A(100s), 9A(95s)
3)with by-pass
4)only in internal triangle circuit.
Dimensions
Operation rule
During start up soft starts rises linearly motor supplying voltage up to nominal value. Motor speed depends on the load torque. Time is independent from frequency or load. In hardest situations kick start function can be used.
Fuse protection
MCI 3 | MCI15BP | MCI 15 | MCi 25 | MCI 30 | MCI 40 | MCI 50 | |
---|---|---|---|---|---|---|---|
Typ 1 gL/gG | 25 A | 50 A | 50 A | 80 A | 125 A | ||
Typ 2I2t | 72 | 1800 | 1800 | 6300 | 25300 |
Connection scheme
MCI 15, MCI25 | MCI 30 I-O | MCI 50-3 I-O |
Atsiųskite užklausą
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
Susisiekite su mumis
KLAUSKITE PRODUKTO
close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO
close
tu turi būti prisijungęs
MCI soft starts are verified solutions for 3 phase asynchronous motors start up.They keep start up currents on reasonable level, which allow to elongate the non failure operation of machine.
They are perfect solutions for application where there are many soft start cycles.
They can be used with pumps and ventilators, feeders, transporters. Because of set up start torque and unique function (kick start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start ups and stops, which make production lines more reliable. Also start up currents reduction lowers voltage drops on light mains.
- Unlimited turn ons per hour
- start up time set up
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-30 s, MCI 40-3D I-O; MCI 50 I-O
- coasting time set up:
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-60 s, MCI 40-3D I-O; MCI 50 I-O
- set up starting toque up to 85 %
- static friction forcing (kick start)
- universal control voltage 24-480V ac/dc
- maximum operation voltage up to 600 V Ac
- Control in three phases - some models
- Automatic phase decay detection
- Automatic adaptation to 50/60 Hz
- LED operation indicator
- build in protection varistor
- optional additional contacts
- easy and quick assembly
- compact construction with radiator
- DIN assembled
- standards EN 60947-4-2
- Certificates CE and UL (UL 508)
1)DIN width assembly
2)Needed down time between soft starts for 15A is 110s, 12A(100s), 9A(95s)
3)with by-pass
4)only in internal triangle circuit.
During start up soft starts rises linearly motor supplying voltage up to nominal value. Motor speed depends on the load torque. Time is independent from frequency or load. In hardest situations kick start function can be used.
They are perfect solutions for application where there are many soft start cycles.
They can be used with pumps and ventilators, feeders, transporters. Because of set up start torque and unique function (kick start) which force static friction, they are able to cope with almost every application. They reduce stresses and vibrations during start ups and stops, which make production lines more reliable. Also start up currents reduction lowers voltage drops on light mains.
Properties
- Unlimited turn ons per hour
- start up time set up
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-30 s, MCI 40-3D I-O; MCI 50 I-O
- coasting time set up:
0-10 s, MCI 3, MCI 15, MCI 15BP, MCI 25; 0-20 s, MCI 30 I-O; 0-60 s, MCI 40-3D I-O; MCI 50 I-O
- set up starting toque up to 85 %
- static friction forcing (kick start)
- universal control voltage 24-480V ac/dc
- maximum operation voltage up to 600 V Ac
- Control in three phases - some models
- Automatic phase decay detection
- Automatic adaptation to 50/60 Hz
- LED operation indicator
- build in protection varistor
- optional additional contacts
- easy and quick assembly
- compact construction with radiator
- DIN assembled
- standards EN 60947-4-2
- Certificates CE and UL (UL 508)
Type | Operation voltage V ac |
motor power | motor current | Width L [mm]1) |
Additional contacts | Catalogue number |
---|---|---|---|---|---|---|
MCI 3 | 380 - 415 | 1,5kW | 3 A | 22,5 | - | 037N0074 |
MCI 3 | 440 - 480 | 1,5kW | 3 A | 22,5 | - | 037N0084 |
MCI 15BP | 400 - 415 | 7,5kW2) | 15 A2) | 45 | - | 037N0139 |
MCI 15 | 380 - 480 | 7,5kW | 15 A | 45 | - | 037N0039 |
MCI 25 | 380 - 480 | IlkW | 25 A | 90 | - | 037N0040 |
MCI 30 | 380 - 480 | 15kW3) | 25/303) A | 90 | IO/bypass | 037N0070 |
MCI 40-3D IO | 380 - 480 | 21kW4) | 29/433) A | 90 | IO/bypass | 037N0092 |
MCI 50-3 10 | 380 - 480 | 22kW3) | 35/503) A | 180 | IO/bypass | 037N0090 |
MCI 50-3 10 | 380 - 480 | 45kW4) | 863) A | 180 | IO/bypass | 037N0090 |
MCI 3 | 500 - 600 | 2,2kW | 3 A | 22,5 | - | 037N0075 |
MCI 15 | 500 - 600 | 7,5kW | 15 A | 45 | - | 037N0041 |
MCI 25 | 500 - 600 | 15kW | 25 | 90 | - | 037N0042 |
MCI 30 | 500 - 600 | 18,5kW3) | 25/303) A | 90 | IO/bypass | 037N0071 |
MCI 50-3 10 | 500 - 600 | 30kW3) | 35/503) A | ISO | IO/bypass | 037N0091 |
1)DIN width assembly
2)Needed down time between soft starts for 15A is 110s, 12A(100s), 9A(95s)
3)with by-pass
4)only in internal triangle circuit.
Dimensions
Operation rule
During start up soft starts rises linearly motor supplying voltage up to nominal value. Motor speed depends on the load torque. Time is independent from frequency or load. In hardest situations kick start function can be used.
Fuse protection
MCI 3 | MCI15BP | MCI 15 | MCi 25 | MCI 30 | MCI 40 | MCI 50 | |
---|---|---|---|---|---|---|---|
Typ 1 gL/gG | 25 A | 50 A | 50 A | 80 A | 125 A | ||
Typ 2I2t | 72 | 1800 | 1800 | 6300 | 25300 |
Connection scheme