Varžos jutiklis su jungtimi ir laidu ACT-21
  • Varžos jutiklis su jungtimi ir laidu ACT-21

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: DACPOL

Varžos jutiklis su jungtimi ir laidu ACT-21

Resistant sensor with stub pipe and cable is used for temperature measurement in devices and aggregates.  Threaded stub pipe allows for easy and reliable sensor assembly to the measurement socket. Sensor has wide range of usage in aggressive media. Cable is resistant for high temperature up to +400°C.
 
SPECIFICATION:
Type Execution
ACT-21 normal
ACT-21/EXI Spark safe

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type
1xPt100
2xPt100
normal shockproof according to PN-EN-60751 from -50°C
up to +250°C
B 8 mA 2 cables
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA


Shield
diameter
d[mm]

material according to

length
L[mm]

Ø3, Ø4, Ø5 , Ø6, Ø8, Ø9, Ø10 1.4571 arbitrary
  Connection stub pipe
stub pipe D
M12x1, M12x1.5, M14x1.5, M20x1.5
G1/4”, G3/8”, G 1/2’’

Connection cable
Type Diameter Type Composition Maks. temp. pracy Długość LK
2 przewody Ø2,9 L2GGD-2x0,22mm2 fibre glass +400°C arbitrary
3, 4 przewody Ø3,1 L4GGD-4x0,22mm2 fibre glass +400°C
2 przewody Ø4,2 L4TS-2x0,34mm2 teflon, silicon +180°C
3, 4 przewody Ø4,3 L4TS-4x0,22mm2 teflon, silicon +180°C
3, 4 przewody Ø2,9 L4TT-4x0,22mm2 teflon, teflon +260°C
3 przewody Ø3,8 L6TT-6x0,22mm2 teflon, teflon +260°C
2 przewody Ø4,3 L2SDS-2x0,25mm2 silicon, +180°C
3, 4 przewody Ø4,4 L4TDS-4x0,25mm2 teflon, silicon +180°C
3, 4 przewody Ø4 L4TFDT-4x0,22mm2 teflon, foil, +260°C




Marking:
A. Execution
A
 
Normal
-
  Spark safe /Exi
B. Resistor type
B
 
Single Pt100
1xPt100
 
Double Pt100
2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Shield diameter d
D
 
Ø4
4
 
Ø5
5
 
Ø6
6
 
Ø8
8
 
Ø9
9
 
Ø10
10
E. Stub pipe thread D
E
 
M12x1
M12x1
 
M12x1,5
M12x1,5
 
M14x1,5
M14x1,5
 
M20x1,5
M20x1,5
 
G 1/4''
G 1/4
 
G 3/8''
G 3/8
 
G 1/2''
G 1/2
F. Shield material
F
 
1.4571
1.4571
G. Shield length
G
 
L
give in mm
H. Connection and cable type
H
 
2 cables (L2GGD)
2p-L2GGD
 
3 cables (L4GGD)
3p-L4GGD
 
4 cables (L4GGD)
4p-L4GGD
 
2 cables (L2TS)
2p-L2TS
 
3 cables (L4TS)
3p-L4TS
 
4 cables (L4TS)
4p-L4TS
 
3 cables (L4TT)
3p-L4TT
 
4 cables (L4TT)
4p-L4TT
 
3 cables (L6TT)
3p-L6TT
 
2 cables (L2SDS)
2p-L2SDS
 
3 cables (L4TDS)
3p-L4TDS
 
4 cables (L4TDS)
4p-L4TDS
 
3 cables (L4TFDT)
3p-L4TFDT
 
4 cables (L4TFDT)
4p-L4TFDT
I. Cable length
I
 
LK
give in mm
J.Sensor type
K
 
normal
Z
 
shockproof
W
 

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

Resistant sensor with stub pipe and cable is used for temperature measurement in devices and aggregates.  Threaded stub pipe allows for easy and reliable sensor assembly to the measurement socket. Sensor has wide range of usage in aggressive media. Cable is resistant for high temperature up to +400°C.
 
SPECIFICATION:
Type Execution
ACT-21 normal
ACT-21/EXI Spark safe

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type
1xPt100
2xPt100
normal shockproof according to PN-EN-60751 from -50°C
up to +250°C
B 8 mA 2 cables
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA


Shield
diameter
d[mm]

material according to

length
L[mm]

Ø3, Ø4, Ø5 , Ø6, Ø8, Ø9, Ø10 1.4571 arbitrary
  Connection stub pipe
stub pipe D
M12x1, M12x1.5, M14x1.5, M20x1.5
G1/4”, G3/8”, G 1/2’’

Connection cable
Type Diameter Type Composition Maks. temp. pracy Długość LK
2 przewody Ø2,9 L2GGD-2x0,22mm2 fibre glass +400°C arbitrary
3, 4 przewody Ø3,1 L4GGD-4x0,22mm2 fibre glass +400°C
2 przewody Ø4,2 L4TS-2x0,34mm2 teflon, silicon +180°C
3, 4 przewody Ø4,3 L4TS-4x0,22mm2 teflon, silicon +180°C
3, 4 przewody Ø2,9 L4TT-4x0,22mm2 teflon, teflon +260°C
3 przewody Ø3,8 L6TT-6x0,22mm2 teflon, teflon +260°C
2 przewody Ø4,3 L2SDS-2x0,25mm2 silicon, +180°C
3, 4 przewody Ø4,4 L4TDS-4x0,25mm2 teflon, silicon +180°C
3, 4 przewody Ø4 L4TFDT-4x0,22mm2 teflon, foil, +260°C




Marking:
A. Execution
A
 
Normal
-
  Spark safe /Exi
B. Resistor type
B
 
Single Pt100
1xPt100
 
Double Pt100
2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Shield diameter d
D
 
Ø4
4
 
Ø5
5
 
Ø6
6
 
Ø8
8
 
Ø9
9
 
Ø10
10
E. Stub pipe thread D
E
 
M12x1
M12x1
 
M12x1,5
M12x1,5
 
M14x1,5
M14x1,5
 
M20x1,5
M20x1,5
 
G 1/4''
G 1/4
 
G 3/8''
G 3/8
 
G 1/2''
G 1/2
F. Shield material
F
 
1.4571
1.4571
G. Shield length
G
 
L
give in mm
H. Connection and cable type
H
 
2 cables (L2GGD)
2p-L2GGD
 
3 cables (L4GGD)
3p-L4GGD
 
4 cables (L4GGD)
4p-L4GGD
 
2 cables (L2TS)
2p-L2TS
 
3 cables (L4TS)
3p-L4TS
 
4 cables (L4TS)
4p-L4TS
 
3 cables (L4TT)
3p-L4TT
 
4 cables (L4TT)
4p-L4TT
 
3 cables (L6TT)
3p-L6TT
 
2 cables (L2SDS)
2p-L2SDS
 
3 cables (L4TDS)
3p-L4TDS
 
4 cables (L4TDS)
4p-L4TDS
 
3 cables (L4TFDT)
3p-L4TFDT
 
4 cables (L4TFDT)
4p-L4TFDT
I. Cable length
I
 
LK
give in mm
J.Sensor type
K
 
normal
Z
 
shockproof
W