          Jūs turite būti prisijungę
Category
 
         
          Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją
please use latin characters
 Properties:
 • One element power thyristor block with both side cooling– RY
• Water cooling
 
 Typical applications:
 • rectifiers, converters, supplies.  
 • DC power regulators
 • power contactors
 • soft-starts
 
 Option:
 • assembled on clamp K-1 – Drawing. 1
 • assembled on clamp K-2 special execution.– Drawing. 2
 • assembled on clamp K-5 special execution.– Drawing. 3
 • Thermal protection
• RC circuit
• fuse
 Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
 Operation conditions:
 One element power blocks are used in power electronic systems.
 • cooling water temperature 50 C - 300 C @ ambient temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa
| Drawing 1 | Drawing 2 | 
|  |  | 
| Drawing 3 | |
|  | Scheme | 
| Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] | Over current I FSM [A] | Semiconductor size [mm] | Block weight [kg] | 
|---|---|---|---|---|---|
| M2T75W | 650…960 | 400…2200 | 8000… 12000 |  | 1,4 | 
| M2T7W | 450…650 | 400…2400 | 7000…10000 |  | 1,6 | 
| M2T8W | 630…1000 | 400…8500 | 10000…24000 |  | 1,6 | 
| M2T9W | 1000…2000 | 400…7500 | 20000…42000 |  | 3,2 | 
| M2T11W | 1000…3200 | 400…7200 | 27000…65000 |  | 9,8 | 


Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
 Properties:
 • One element power thyristor block with both side cooling– RY
• Water cooling
 
 Typical applications:
 • rectifiers, converters, supplies.  
 • DC power regulators
 • power contactors
 • soft-starts
 
 Option:
 • assembled on clamp K-1 – Drawing. 1
 • assembled on clamp K-2 special execution.– Drawing. 2
 • assembled on clamp K-5 special execution.– Drawing. 3
 • Thermal protection
• RC circuit
• fuse
 Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
 Operation conditions:
 One element power blocks are used in power electronic systems.
 • cooling water temperature 50 C - 300 C @ ambient temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa
| Drawing 1 | Drawing 2 | 
|  |  | 
| Drawing 3 | |
|  | Scheme | 
| Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] | Over current I FSM [A] | Semiconductor size [mm] | Block weight [kg] | 
|---|---|---|---|---|---|
| M2T75W | 650…960 | 400…2200 | 8000… 12000 |  | 1,4 | 
| M2T7W | 450…650 | 400…2400 | 7000…10000 |  | 1,6 | 
| M2T8W | 630…1000 | 400…8500 | 10000…24000 |  | 1,6 | 
| M2T9W | 1000…2000 | 400…7500 | 20000…42000 |  | 3,2 | 
| M2T11W | 1000…3200 | 400…7200 | 27000…65000 |  | 9,8 | 