Drėgmės ir temperatūros jutikliai meteorologinėms reikmėms
  • Drėgmės ir temperatūros jutikliai meteorologinėms reikmėms

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Drėgmės ir temperatūros jutikliai meteorologinėms reikmėms

Humidity and temperature sensors for meteorological applications

Mela®-humidity/-temperature sensors in the PC-ME series with a fixed connecting cable (5 m), PK-ME series without cable or RC-ME series with a robust aluminium connecting head and terminal screws are compact sensors in a rod-type design. They have a high degree of accuracy and have been specially developed for meteorological applications. All the sensors in the series are fitted with the ZE20-type membrane filter. We recommend that you use the version with the the ZE 21/ZE22 ¹) type sintered high-grade steel filter (filter programme see product info sheet no. F 5.1)at high wind speeds or if the sensor is exposed to salt mist, sand or dust (near the sea, industrial estates etc.). The advantage of the .../9 series is the improved temperature dynamics, in particular at low air speeds.

 

Technical Data

Relative humidity
Measuring range 0…100%rh
Accuracy (5…95%rh at. 10…40°C) ±2% rh
influence of temperature <10°C lub >40°C <0,1% /K
Temperature
Measuring element (klasa 1.3 DIN En60751) Pt100 klasa B
Measuring range -30…+70°C
Accuracy 0-1V (-27…80°C) ±0,2K
0-10V (-29…80°C) ±0,2K
Influence of temperature. <10°C lub >40°C ±0,007K/K
Other data:
Ambient temperature -40…+80 °C
Degree of protection sensor/electronic IP30/IP65
Degree of protection connector IP67
Operating voltage voltage output 0…10V 15…30VDC
Voltage output 0…1V 6…30VDC
Load resistance ( 0…10V/0…1V) ≥10kΩ/≥2 kΩ
Power consumption 0…10V, 2x0…1V ok. 5mA
0…1V <1mA
Minimum air speed always at right angles to the sensor output: 0…10V, 2x0…1V ≥0.5 m/s
2x0…10V [&]ge 1 m/s
Self-heating coefficient Pt100 Pt100 (v=2m/s) 0,2K/mW
Directive about electromagnetic compatibility EN 61326-2-3


Measured variable Output signals Remote sensor cable 5m Sensor with connector The sensor wires to be soldered
F
rel. humidity (rh)

0...10V

FPC2/5-ME

FPC2.S/6-ME

FPK2/9-ME

0...1V

FPC1/5-ME

FPC1.S/6-ME

FPK1/9-ME

C
r.h. + temp.

0...10V, Pt100

CPC2/5-ME

CPC2.S/6-ME

CPK2/9-ME

0...1V, Pt100

CPC1/5-ME

CPC1.S/6-ME

CPK1/9-ME

K
r.h. + temp.

2 x 0...10V

KPC2/5-ME

KPC2.S/6-ME

KPK2/9-ME

2 x 0...1V

KPC1/5-ME

KPC1.S/6-ME

KPK1/9-ME

T
temperature

Pt100

TPC5/5-ME

TPC5.S/6-ME

TPK5/9-ME

0.10V

TPC2/5-ME

TPC2.S/6-ME

TPK2/9-ME

0.1V

TPC1/5-ME

TPC1.S/6-ME

TPK1/9-ME


 

Czujniki wilgotności i temperatury do zastosowań meteorologicznych


Recommended working range for humidity

Czujniki wilgotności i temperatury do zastosowań meteorologicznych wykres

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis

KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

Humidity and temperature sensors for meteorological applications

Mela®-humidity/-temperature sensors in the PC-ME series with a fixed connecting cable (5 m), PK-ME series without cable or RC-ME series with a robust aluminium connecting head and terminal screws are compact sensors in a rod-type design. They have a high degree of accuracy and have been specially developed for meteorological applications. All the sensors in the series are fitted with the ZE20-type membrane filter. We recommend that you use the version with the the ZE 21/ZE22 ¹) type sintered high-grade steel filter (filter programme see product info sheet no. F 5.1)at high wind speeds or if the sensor is exposed to salt mist, sand or dust (near the sea, industrial estates etc.). The advantage of the .../9 series is the improved temperature dynamics, in particular at low air speeds.

 

Technical Data

Relative humidity
Measuring range 0…100%rh
Accuracy (5…95%rh at. 10…40°C) ±2% rh
influence of temperature <10°C lub >40°C <0,1% /K
Temperature
Measuring element (klasa 1.3 DIN En60751) Pt100 klasa B
Measuring range -30…+70°C
Accuracy 0-1V (-27…80°C) ±0,2K
0-10V (-29…80°C) ±0,2K
Influence of temperature. <10°C lub >40°C ±0,007K/K
Other data:
Ambient temperature -40…+80 °C
Degree of protection sensor/electronic IP30/IP65
Degree of protection connector IP67
Operating voltage voltage output 0…10V 15…30VDC
Voltage output 0…1V 6…30VDC
Load resistance ( 0…10V/0…1V) ≥10kΩ/≥2 kΩ
Power consumption 0…10V, 2x0…1V ok. 5mA
0…1V <1mA
Minimum air speed always at right angles to the sensor output: 0…10V, 2x0…1V ≥0.5 m/s
2x0…10V [&]ge 1 m/s
Self-heating coefficient Pt100 Pt100 (v=2m/s) 0,2K/mW
Directive about electromagnetic compatibility EN 61326-2-3


Measured variable Output signals Remote sensor cable 5m Sensor with connector The sensor wires to be soldered
F
rel. humidity (rh)

0...10V

FPC2/5-ME

FPC2.S/6-ME

FPK2/9-ME

0...1V

FPC1/5-ME

FPC1.S/6-ME

FPK1/9-ME

C
r.h. + temp.

0...10V, Pt100

CPC2/5-ME

CPC2.S/6-ME

CPK2/9-ME

0...1V, Pt100

CPC1/5-ME

CPC1.S/6-ME

CPK1/9-ME

K
r.h. + temp.

2 x 0...10V

KPC2/5-ME

KPC2.S/6-ME

KPK2/9-ME

2 x 0...1V

KPC1/5-ME

KPC1.S/6-ME

KPK1/9-ME

T
temperature

Pt100

TPC5/5-ME

TPC5.S/6-ME

TPK5/9-ME

0.10V

TPC2/5-ME

TPC2.S/6-ME

TPK2/9-ME

0.1V

TPC1/5-ME

TPC1.S/6-ME

TPK1/9-ME


 

Czujniki wilgotności i temperatury do zastosowań meteorologicznych


Recommended working range for humidity

Czujniki wilgotności i temperatury do zastosowań meteorologicznych wykres