C1FS/I cables are specially designed for heating concrete tracks for VAL type metros. They can be terminated into copper tubes.
C2FS/I cables are specially designed for heating metal metro tracks and rails of the VAL type. They can be slid inside a U-shaped composite profile clamped against the rail with stainless steel clips.
R3FS/I tapes are used when it is required to trace very long stretches, where a 400V, 3-phase power supply is available, for example in pits or tunnels. To ensure that these heating elements enjoy a long service life, we recommend using a control device.
| C1FS/I | C2FS/I | R3FS/I | |
|---|---|---|---|
| Heating strand | niklowo-miedziany lub niklowo-chromowy | ||
| Dimensions | Ø 6.5 mm | 5 x 9 mm | 7 x 16 mm |
| Max. power | 40 W/m | 60 W/m | 80 W/m |
| Max. voltage | 750 V | ||
| conductor insulation | Fluoropolymer | ||
| External insulation | Silicon elastomer | ||
| Permissible surface temperature | from - 70°C to +200°C | ||
| Toleracne | Resistance ± 10 % | ||
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
C1FS/I cables are specially designed for heating concrete tracks for VAL type metros. They can be terminated into copper tubes.
C2FS/I cables are specially designed for heating metal metro tracks and rails of the VAL type. They can be slid inside a U-shaped composite profile clamped against the rail with stainless steel clips.
R3FS/I tapes are used when it is required to trace very long stretches, where a 400V, 3-phase power supply is available, for example in pits or tunnels. To ensure that these heating elements enjoy a long service life, we recommend using a control device.
| C1FS/I | C2FS/I | R3FS/I | |
|---|---|---|---|
| Heating strand | niklowo-miedziany lub niklowo-chromowy | ||
| Dimensions | Ø 6.5 mm | 5 x 9 mm | 7 x 16 mm |
| Max. power | 40 W/m | 60 W/m | 80 W/m |
| Max. voltage | 750 V | ||
| conductor insulation | Fluoropolymer | ||
| External insulation | Silicon elastomer | ||
| Permissible surface temperature | from - 70°C to +200°C | ||
| Toleracne | Resistance ± 10 % | ||