AC / DC True RMS - Série CP4
  • AC / DC True RMS - Série CP4

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: GMC-I PROSyS

AC / DC True RMS - Série CP4

  • AC/DC low current measurement down to mAmps
  • Auto ranging 4/40A with 1/10mA resolution (CP41)
  • Auto ranging 40/400A with 10/100mA resolution (CP410)
  • Auto ranging 400/1000A with 100mA/1A resolution (CP1010)
  • Conformance to IEC1010 and EMC standards
  • Auto Zero and Auto Power Off
  • Low battery indicator
  • Compact lightweight design
Typical applications
  • Leakage current measurements (CP41)
  • Process control for 4 – 20mA current loop verification (CP41)
  • Battery charging systems
  • Starting currents
  • Light industrial and residential electrical installation testing
 

Specifications

Non-invasive current measurement

MODEL

CP 41

CP 410

CP 1010

Current Ranges (auto-ranging) 4A/40A DC lub ACPeak 40/400A DC lub ACPeaka 400/1000A DC lub ACPeak
Measurement method True RMS, msec response time
Resolution ±1mA / ±10mA ±10mA / ±100mA ±100mA / ±1A
Basic Accuracy ±1% of reading ± 5 digits

Frequency response
DC
DC
AC
15Hz – 400Hz

Display

 
Size and type
4000-count LCD SAFETY 10mm characters
Status indication
Low Battery, Polarity
Refresh rate
2 times per second

Power supply  

Battery type
9V Alkaline: MN1604, PP3 IEC 6LR61 or equivalent
Battery life
15 hours (CP41) 50 hours (CP410/CP1010)

Mechanical data

Dimensions (mm)
194 (H) x 74 (W) x 25 (D)
Jaw Capacity
25mm  Ø (CP41/CP410)
32mm  Ø(CP1O1O)
Weight
235g
Environmental data
 

Operating temperature

0°C do 50°C
Temperature Coefficient
± 0.15% of reading per °C
Storage Temperature (without battery)
-20°C do 85°C

Safety

EN61010-2-032:2002, 300V, Measurement Category III, Pollution Degree 2

Maximum safe voltages

300V AC RMS or DC between uninsulated conductor and ground
EMC Standard EN 61326-2-2:2006
All accuracies stated at 23°C ± 1°C (73.4°F ± 1.8°F

High Accuracy
Advanced patented magnetic circuit design results in accuracy to be little affected by external magnetic
fields or off-centre conductor positioning.

EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.

Part No

CP41

CP410

CP1010

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter

DEMANDEZ LE PRODUIT close
Message envoyé avec succès.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

  • AC/DC low current measurement down to mAmps
  • Auto ranging 4/40A with 1/10mA resolution (CP41)
  • Auto ranging 40/400A with 10/100mA resolution (CP410)
  • Auto ranging 400/1000A with 100mA/1A resolution (CP1010)
  • Conformance to IEC1010 and EMC standards
  • Auto Zero and Auto Power Off
  • Low battery indicator
  • Compact lightweight design
Typical applications
  • Leakage current measurements (CP41)
  • Process control for 4 – 20mA current loop verification (CP41)
  • Battery charging systems
  • Starting currents
  • Light industrial and residential electrical installation testing
 

Specifications

Non-invasive current measurement

MODEL

CP 41

CP 410

CP 1010

Current Ranges (auto-ranging) 4A/40A DC lub ACPeak 40/400A DC lub ACPeaka 400/1000A DC lub ACPeak
Measurement method True RMS, msec response time
Resolution ±1mA / ±10mA ±10mA / ±100mA ±100mA / ±1A
Basic Accuracy ±1% of reading ± 5 digits

Frequency response
DC
DC
AC
15Hz – 400Hz

Display

 
Size and type
4000-count LCD SAFETY 10mm characters
Status indication
Low Battery, Polarity
Refresh rate
2 times per second

Power supply  

Battery type
9V Alkaline: MN1604, PP3 IEC 6LR61 or equivalent
Battery life
15 hours (CP41) 50 hours (CP410/CP1010)

Mechanical data

Dimensions (mm)
194 (H) x 74 (W) x 25 (D)
Jaw Capacity
25mm  Ø (CP41/CP410)
32mm  Ø(CP1O1O)
Weight
235g
Environmental data
 

Operating temperature

0°C do 50°C
Temperature Coefficient
± 0.15% of reading per °C
Storage Temperature (without battery)
-20°C do 85°C

Safety

EN61010-2-032:2002, 300V, Measurement Category III, Pollution Degree 2

Maximum safe voltages

300V AC RMS or DC between uninsulated conductor and ground
EMC Standard EN 61326-2-2:2006
All accuracies stated at 23°C ± 1°C (73.4°F ± 1.8°F

High Accuracy
Advanced patented magnetic circuit design results in accuracy to be little affected by external magnetic
fields or off-centre conductor positioning.

EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.

Part No

CP41

CP410

CP1010