SILICOUL 1,1kV -60 ° C a + 180 ° C (Clase H)
  • SILICOUL 1,1kV -60 ° C a + 180 ° C (Clase H)

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: OMERIN

SILICOUL 1,1kV -60 ° C a + 180 ° C (Clase H)

Characteristics
• Continuous operating temperatures: -60 °C to +180 °C
• Good resistance to thermal shock and UV
• Excellent mechanical strength.
• Rated voltage: 1.1 kV
• Test voltage: 3.5 kV

Standard products
• Standard insulation colour: white.
• Standard reinforcing braid colour: yellow.
• Standard marking: OMERIN - SILICOUL 1.1 KV - {cross-section}

No printing on sections 1.5 mm2 to 6 mm2

Approvals - standards
• Smoke classification F1 as per NF F 16-101.
• Bureau VERITAS approval certificates: compliance with the tests described as per standards
IEC 60092-350/353/360, IEC 60228,
IEC 60331-11/21, IEC 60332-1-1/2,
EC 60332-3-22 and IEC 60754-2.
• Lloyd’s Register approval certificates: compliance with the tests described as per standards
IEC 60228, IEC 60092-350/353/360,
IEC 60754-2, IEC 60332-1-1/2,
IEC 60332-3-22 category A and IEC 60331-11/21.

Applications
• Cabling for rotating machines: motors, alternators, generators
• Cabling for static machines: transformers, inductors, inverters, choppers.
• Shipbuilding and railway construction.
• Power cabinets.

Options
• Extra-flexible tin-plated copper core - class 6 as per IEC 60228: contact us.
• Flexible or extra-flexible bare copper, silver-plated or nickel-plated copper core – class 5 or 6 as per IEC 60228: contact us
• Without reinforcing braid (ref. SILICOUL® ST 1.1 KV): contact us.
• Varnished synthetic fibre reinforcing braid (ref. SILICOUL® RI 1.1 KV): contact us.
• Very high temperature fibre reinforcing braid: contact us.
• Outer flexible armour: > Galvanised steel braid (ref. SILICOUL® BG 1.1 KV): contact us. > Stainless steel braid (ref. SILICOUL® BI 1.1 KV): contact us
• Multi-conductor cable made up of an assembly of several single conductor cables SILICOUL® 1.1 KV: contact us.
• Other markings: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us
• Other options and/or combinations of the options outlined above: contact us.


1 • Flexible tin-plated copper core - class 5 as per IEC 60228.
2 • Optional separating tape.
3 • Insulation: Silicone rubber
4 • Reinforcement: Coated synthetic fibre braid.

 
Nominal cross-section
[mm 2]
Nominal stranding Maximum linear resistance at 20 °C (Ω/km) Nominal diameter
[mm]
Approximate linear weight 
[kg/km]
1.5 30 x 0.25 13.7 3.8 23.5
2.5 50 x 0.25 8.21 4.3 34.0
4 56 x 0.30 5.09 4.9 48.9
6 84 x 0.30 3.39 6.0 71.7
10 80 x 0.40 1.95 7.2 117
16 126 x 0.40 1.24 8.6 174
25 196 x 0.40 0.795 10.4 268
35 276 x 0.40 0.565 1 1.9 360
50 396 x 0.40 0.393 14.1 512
70 360 x 0.50 0.277 15.9 686
95 485 x 0.50 0.210 18.2 914
120 608 x 0.50 0.164 20.7 1174
150 756 x 0.50 0.132 23.2 1457
185 944 x 0.50 0.108 25.2 1819
240 1221 x 0.50 0.0817 29.2 2448
300 1525 x 0.50 0.0654 31.6 2992
400 2037 x 0.50 0.0495 34.6 3837

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras

SOLICITA EL PRODUCTO close
Mensaje enviado con éxito.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Characteristics
• Continuous operating temperatures: -60 °C to +180 °C
• Good resistance to thermal shock and UV
• Excellent mechanical strength.
• Rated voltage: 1.1 kV
• Test voltage: 3.5 kV

Standard products
• Standard insulation colour: white.
• Standard reinforcing braid colour: yellow.
• Standard marking: OMERIN - SILICOUL 1.1 KV - {cross-section}

No printing on sections 1.5 mm2 to 6 mm2

Approvals - standards
• Smoke classification F1 as per NF F 16-101.
• Bureau VERITAS approval certificates: compliance with the tests described as per standards
IEC 60092-350/353/360, IEC 60228,
IEC 60331-11/21, IEC 60332-1-1/2,
EC 60332-3-22 and IEC 60754-2.
• Lloyd’s Register approval certificates: compliance with the tests described as per standards
IEC 60228, IEC 60092-350/353/360,
IEC 60754-2, IEC 60332-1-1/2,
IEC 60332-3-22 category A and IEC 60331-11/21.

Applications
• Cabling for rotating machines: motors, alternators, generators
• Cabling for static machines: transformers, inductors, inverters, choppers.
• Shipbuilding and railway construction.
• Power cabinets.

Options
• Extra-flexible tin-plated copper core - class 6 as per IEC 60228: contact us.
• Flexible or extra-flexible bare copper, silver-plated or nickel-plated copper core – class 5 or 6 as per IEC 60228: contact us
• Without reinforcing braid (ref. SILICOUL® ST 1.1 KV): contact us.
• Varnished synthetic fibre reinforcing braid (ref. SILICOUL® RI 1.1 KV): contact us.
• Very high temperature fibre reinforcing braid: contact us.
• Outer flexible armour: > Galvanised steel braid (ref. SILICOUL® BG 1.1 KV): contact us. > Stainless steel braid (ref. SILICOUL® BI 1.1 KV): contact us
• Multi-conductor cable made up of an assembly of several single conductor cables SILICOUL® 1.1 KV: contact us.
• Other markings: contact us.
• Other colours: contact us.
• Other nominal cross-sections: contact us
• Other options and/or combinations of the options outlined above: contact us.


1 • Flexible tin-plated copper core - class 5 as per IEC 60228.
2 • Optional separating tape.
3 • Insulation: Silicone rubber
4 • Reinforcement: Coated synthetic fibre braid.

 
Nominal cross-section
[mm 2]
Nominal stranding Maximum linear resistance at 20 °C (Ω/km) Nominal diameter
[mm]
Approximate linear weight 
[kg/km]
1.5 30 x 0.25 13.7 3.8 23.5
2.5 50 x 0.25 8.21 4.3 34.0
4 56 x 0.30 5.09 4.9 48.9
6 84 x 0.30 3.39 6.0 71.7
10 80 x 0.40 1.95 7.2 117
16 126 x 0.40 1.24 8.6 174
25 196 x 0.40 0.795 10.4 268
35 276 x 0.40 0.565 1 1.9 360
50 396 x 0.40 0.393 14.1 512
70 360 x 0.50 0.277 15.9 686
95 485 x 0.50 0.210 18.2 914
120 608 x 0.50 0.164 20.7 1174
150 756 x 0.50 0.132 23.2 1457
185 944 x 0.50 0.108 25.2 1819
240 1221 x 0.50 0.0817 29.2 2448
300 1525 x 0.50 0.0654 31.6 2992
400 2037 x 0.50 0.0495 34.6 3837