Contactores de tiristores DAC
  • Contactores de tiristores DAC

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: DACPOL SERVICE

Contactores de tiristores DAC

Thyristor contactors


Use

Supply voltage switching: resistance furnaces, incandescent lamps, discharge lamps, direct motor starting.


Features

Long service life, resistance to power line surges, surge-free on/off switching of loads, quiet operation, compliance with PN-EN 60947-4-3.



Technical data

Type DAC1 DAC2 DAC3
Power supply
3x400 V, 50 Hz 3x400 V, 50 Hz 3x400 V, 50 Hz
Rated current (range) 30 A, 40 A, 50 A 60 A, 80 A, 100 A, 120 A, 160 A, 180 A 250 A, 300 A
Supply voltage tolerance -15% ÷ +10% Un
Usage categories AC51, AC55aa, AC55b, AC52a, AC52b, AC53a, AC53b
Control signals* 12 VDC, 12 VAC, 24 VDC, 24 VAC, 110 VDC, 230 VAC
Thyristor control Zero-voltage switch-on
Receiver connection system star or triangle
Surge protection RC suppressor
Cooling air forced air with own fans forced air with own fans
Ingress Protection IP00
Insulation test voltage 2,5 kV
Degree of contamination 3
Operating temperature range 0 - 50 °C
Storage temperature range -20 ÷ 60 °C
Protective cover metaplex
Short-circuit protection fast fuses
Relative humidity
up to 85% (condensation-free)
Altitude up to 1000 m
Rectangle of fixing holes 155x175 mm 155x175 mm (DAC2 60, 80); 280x155 mm (other) 280x410 mm
Dimensions (D x W x H) 200x185x255 mm 240x185x255 mm (DAC 60, 80);
340x175x255 mm (other)
340x380x260 mm
Weight 5,5 kg 6-9.5 kg 28 kg

Notice:
* Please specify the type of control signal in your order.

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras

SOLICITA EL PRODUCTO close
Mensaje enviado con éxito.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Thyristor contactors


Use

Supply voltage switching: resistance furnaces, incandescent lamps, discharge lamps, direct motor starting.


Features

Long service life, resistance to power line surges, surge-free on/off switching of loads, quiet operation, compliance with PN-EN 60947-4-3.



Technical data

Type DAC1 DAC2 DAC3
Power supply
3x400 V, 50 Hz 3x400 V, 50 Hz 3x400 V, 50 Hz
Rated current (range) 30 A, 40 A, 50 A 60 A, 80 A, 100 A, 120 A, 160 A, 180 A 250 A, 300 A
Supply voltage tolerance -15% ÷ +10% Un
Usage categories AC51, AC55aa, AC55b, AC52a, AC52b, AC53a, AC53b
Control signals* 12 VDC, 12 VAC, 24 VDC, 24 VAC, 110 VDC, 230 VAC
Thyristor control Zero-voltage switch-on
Receiver connection system star or triangle
Surge protection RC suppressor
Cooling air forced air with own fans forced air with own fans
Ingress Protection IP00
Insulation test voltage 2,5 kV
Degree of contamination 3
Operating temperature range 0 - 50 °C
Storage temperature range -20 ÷ 60 °C
Protective cover metaplex
Short-circuit protection fast fuses
Relative humidity
up to 85% (condensation-free)
Altitude up to 1000 m
Rectangle of fixing holes 155x175 mm 155x175 mm (DAC2 60, 80); 280x155 mm (other) 280x410 mm
Dimensions (D x W x H) 200x185x255 mm 240x185x255 mm (DAC 60, 80);
340x175x255 mm (other)
340x380x260 mm
Weight 5,5 kg 6-9.5 kg 28 kg

Notice:
* Please specify the type of control signal in your order.