Use:
Power control of furnaces with resistance heaters, high-power thermal fans, air conditioners with electric heating, paint dryers.

Features:
Long service life, resistance to power line surges, surge-free on/off switching of loads, quiet operation, compliance with PN-EN 60947-4-3.



Technical data

 
Type GAC1 GAC2 GAC3
Power supply
3x400 V, 50 Hz
Max. current load
30 A, 40 A, 50 A 60 A, 80 A, 100 A, 120 A, 160 A, 180 A 250 A, 400 A
Power supply tolerance
-15% ÷ +10%Un
Category of use AC-51
Features power status, full conduction status, switching function
Control signals* 0-10 VDC
4-20 mA
Thyristors control
group
Receiver connection system star or delta
Surge protection RC suppressor
Cooling air
Ingress Protection
IP00
Insulation test voltage 2,5 kV
Degree of contamination 3
Operating temperature range
0 ÷ 50 °C
Storage temperature range
-20 °C ÷ 60 °C
Shielding metaplex
Short-circuit protection
fast fuses
Relative humidity
up to 85% (no condensation)
Altitude up to 1000 m
Rectangle of fixing holes 155 x 175 mm

155 x 175 mm (GAC2 60 i 80);
280 x 155 mm (other)

280 x 410 mm
Dimensions (L x W x H) 200 x 185 x 255 mm 240 x 185 x 255 mm (DAC 60 i 80);
340 x 175 x 255 mm (other)
340 x 380 x 260 mm
Weight 5,5 kg 6-9,5 kg 28 kg

Attention:
*Please specify the type of control signal in your order.

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras

SOLICITA EL PRODUCTO close
Mensaje enviado con éxito.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Power controllers - GAC


Use:
Power control of furnaces with resistance heaters, high-power thermal fans, air conditioners with electric heating, paint dryers.

Features:
Long service life, resistance to power line surges, surge-free on/off switching of loads, quiet operation, compliance with PN-EN 60947-4-3.



Technical data

 
Type GAC1 GAC2 GAC3
Power supply
3x400 V, 50 Hz
Max. current load
30 A, 40 A, 50 A 60 A, 80 A, 100 A, 120 A, 160 A, 180 A 250 A, 400 A
Power supply tolerance
-15% ÷ +10%Un
Category of use AC-51
Features power status, full conduction status, switching function
Control signals* 0-10 VDC
4-20 mA
Thyristors control
group
Receiver connection system star or delta
Surge protection RC suppressor
Cooling air
Ingress Protection
IP00
Insulation test voltage 2,5 kV
Degree of contamination 3
Operating temperature range
0 ÷ 50 °C
Storage temperature range
-20 °C ÷ 60 °C
Shielding metaplex
Short-circuit protection
fast fuses
Relative humidity
up to 85% (no condensation)
Altitude up to 1000 m
Rectangle of fixing holes 155 x 175 mm

155 x 175 mm (GAC2 60 i 80);
280 x 155 mm (other)

280 x 410 mm
Dimensions (L x W x H) 200 x 185 x 255 mm 240 x 185 x 255 mm (DAC 60 i 80);
340 x 175 x 255 mm (other)
340 x 380 x 260 mm
Weight 5,5 kg 6-9,5 kg 28 kg

Attention:
*Please specify the type of control signal in your order.