Contador de pulsos y series de tacómetro ECH.
  • Contador de pulsos y series de tacómetro ECH.

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: Sisel

Contador de pulsos y series de tacómetro ECH.

Product withdrawn from sale
Replacement model - ENDA EM4401 Digital Timer

  • 48x48mm and 72x72mm sizes.
  • 2x6 digits indicator.
  • Programmable as Counter and RPM/Tachometer.
  • 6 Digits Batch Counter.
  • 9 Digits Total Counter.
  • Period time differences, pulse time, turnover and speed measurement.
  • Easy to use front panel keypad.
  • Counts Up or Down acording to input phase difference.
  • Input frequency can be selected.
  • Input signal can be calibrated to the desired value by multiplying between 0.000001 and 99.9999.
  • Decimal point can be set between 1 and 5.
  • Sensor input type can be selected by using keyped ( PNP, NPN ).
  • Dual setpoint and dual contact relay.
  • SET1 can be selected to dependent on SET2.
  • Output contact relay can be adjusted to continuous output or between
  • 0.01 and 999.9-second intervals.
  • Output delay time can be adjusted in Tachometer Mode.
  • Functional reset selection.
  • 0 - 500000 Offset selection.
  • Parameter access protection.
  • Easy installation.
  • RS485 Modbus communication interface (Specify)

 

Connection diagram:

 

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras

SOLICITA EL PRODUCTO close
Mensaje enviado con éxito.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

Product withdrawn from sale
Replacement model - ENDA EM4401 Digital Timer

  • 48x48mm and 72x72mm sizes.
  • 2x6 digits indicator.
  • Programmable as Counter and RPM/Tachometer.
  • 6 Digits Batch Counter.
  • 9 Digits Total Counter.
  • Period time differences, pulse time, turnover and speed measurement.
  • Easy to use front panel keypad.
  • Counts Up or Down acording to input phase difference.
  • Input frequency can be selected.
  • Input signal can be calibrated to the desired value by multiplying between 0.000001 and 99.9999.
  • Decimal point can be set between 1 and 5.
  • Sensor input type can be selected by using keyped ( PNP, NPN ).
  • Dual setpoint and dual contact relay.
  • SET1 can be selected to dependent on SET2.
  • Output contact relay can be adjusted to continuous output or between
  • 0.01 and 999.9-second intervals.
  • Output delay time can be adjusted in Tachometer Mode.
  • Functional reset selection.
  • 0 - 500000 Offset selection.
  • Parameter access protection.
  • Easy installation.
  • RS485 Modbus communication interface (Specify)

 

Connection diagram: