Transductores de la serie HTR 50 a 500 SB
  • Transductores de la serie HTR 50 a 500 SB

Las fotos son solo para fines informativos. Ver especificaciones de producto

please use latin characters

Fabricante: LEM

Transductores de la serie HTR 50 a 500 SB

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB

Envíe una consulta

¿Estás interesado en este producto? ¿Necesita información adicional o precios individuales?

Contacta con nosotras

SOLICITA EL PRODUCTO close
Mensaje enviado con éxito.
SOLICITA EL PRODUCTO close
Vistazo

Añadir a la lista de deseos

Usted debe estar conectado

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB