Transducteurs de la série HTR 50 à 500-SB
  • Transducteurs de la série HTR 50 à 500-SB

Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Fabricant: LEM

Transducteurs de la série HTR 50 à 500-SB

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter

DEMANDEZ LE PRODUIT close
Message envoyé avec succès.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB