Hersteller: GENERI

Steuerungs- und Steuergeräte Ex zum Bergbau

Ex-proof indicator typeXHL…

Przeciwwybuchowa lampki XHL Type of protection:    IM2 Ex emb I /  II 2GD Ex emb tD II
Service temperature: - 400C do + 850C
IP protection Head: IP 65
IP protection Contacts: IP 20
Conductor cross-section: 2×0,35 mm2 do 2×2,5 mm2
Neck dimensions: Ø 22,5 mm
Total dimensions: (40 × 23 × 60) mm
Body dimensions: (40 × 23 × 48) mm
Nominal current: 20 mA
Maximum current:: 30 mA, impulse 100 mA
Order No.: XHL 230 Y
    Nominal voltage: - 6 V, 12 V, 24 V, 48 V, 110 V, 230 V AC/DC; 110 V, 230 V AC Colour: RED, BLUE, YELLOW, GREEN, WHITE

Ex-proof indicator type XHL…/JB– intrinsically safe

Ex-proof indicator type XHL…/JB– intrinsically safe
Type of protection:
IM1 Ex ia I  II 2GD T68°C Ex ia tD IIC T6
Ambient temperature: - 40°C do + 60°C
IP protection Head: IP 65
IP protection Contacts:IP 20
Conductor cross-section: 2×0,35 mm2 do 2×2,5 mm2
Total dimensions: (40 × 23 × 60) mm
Body dimensions:(40 × 23 × 48) mm
Nominal current: 10 mA
Neck dimensions: Ø 22,5 mm
Maximum input voltage „Ui“: 9; 17 i 28,2 V AC/DC
Order No.: XHL 24 W/IB
    Nominal voltage - 6 V, 12 V, 24 V AC/DC Colour :RED, BLUE, YELLOW, GREEN, WHITE

Ex-proof fuses typeXFU…

Ex-proof fuses typeXFU…
Type of protection:
I M2 Ex ema I IP20  II 2GD Ex ema tD II IP20
Service temperature: -60°C do +84°C
Nominal voltage: 110 V DC, 250 V AC
Conductor cross-section:: 2×0,35 mm2 do 2×2,5 mm2
Dimensions (w × h × d): (40 × 23,5 × 41,5) mm
Order No.: XHU F 100 H
    Time delay:
FFvery quick breaking,
Fquick breaking,
Mnormal,
Tdelayed,
TT very delayed
Nominal current: 50; 63; 80; 100; 125; 160; 200; 350; 315; 400; 500; 630; 800 mА
1; 1,25; 1,6; 2; 2,5; 3,15; 4; 5; 6,3; 8; 10; 12,5; 16 A

Breaking capability (Ik):
H (1500A),
E (150A),
L(35A)

BEx-proof termination elements typeXZ..

BEx-proof termination elements typeXZ..
Type of protection:
I M2 / II 2GD  Ex emb tD I/II T6 IP 20
Service temperature: -55°C do +84°C
Nominal voltage, current, impedance R, capacitance C, diode type, etc. please see the Order No.
Conductor cross-section: 2×0,35 mm2 do 2×2,5 mm2
Dimensions (w × h × d): (40 × 23,5 × 42) mm
Order No.: XZ R 680
    Type of termination element:
D(diode),
R(resistor),
RC(resistor and capacitor),
V(varistor
Value of the termination element: e.g. 680 Ω, 4k7, … resistor value (for Relement); 400 V, … Nominal voltage
(for Varistor and RCelement); 1 Anominal current (for Diode

EX COMPONENTS – POTENTIOMETERS

Ex-proof potentiometer typeX195RP


Ex-proof potentiometer typeX195RP
Type of protection:
I M2 Ex d I
Service temperature: -60°C +85°C
Load: 1W
Max. collector current: 100 mA
Max. nominal voltage: 250 V AC/DC
Impedance characteristics: liniowy
Nominal impedance: 47R -2M2
Values available: 1K, 2K, 5K, 10K
Shaft diameter: Ø6 mm
Connection: 3 wyprowadzone przewody0,35 mm2, każdy o standardowej długości 30 cm

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Ex-proof indicator typeXHL…

Przeciwwybuchowa lampki XHL Type of protection:    IM2 Ex emb I /  II 2GD Ex emb tD II
Service temperature: - 400C do + 850C
IP protection Head: IP 65
IP protection Contacts: IP 20
Conductor cross-section: 2×0,35 mm2 do 2×2,5 mm2
Neck dimensions: Ø 22,5 mm
Total dimensions: (40 × 23 × 60) mm
Body dimensions: (40 × 23 × 48) mm
Nominal current: 20 mA
Maximum current:: 30 mA, impulse 100 mA
Order No.: XHL 230 Y
    Nominal voltage: - 6 V, 12 V, 24 V, 48 V, 110 V, 230 V AC/DC; 110 V, 230 V AC Colour: RED, BLUE, YELLOW, GREEN, WHITE

Ex-proof indicator type XHL…/JB– intrinsically safe

Ex-proof indicator type XHL…/JB– intrinsically safe
Type of protection:
IM1 Ex ia I  II 2GD T68°C Ex ia tD IIC T6
Ambient temperature: - 40°C do + 60°C
IP protection Head: IP 65
IP protection Contacts:IP 20
Conductor cross-section: 2×0,35 mm2 do 2×2,5 mm2
Total dimensions: (40 × 23 × 60) mm
Body dimensions:(40 × 23 × 48) mm
Nominal current: 10 mA
Neck dimensions: Ø 22,5 mm
Maximum input voltage „Ui“: 9; 17 i 28,2 V AC/DC
Order No.: XHL 24 W/IB
    Nominal voltage - 6 V, 12 V, 24 V AC/DC Colour :RED, BLUE, YELLOW, GREEN, WHITE

Ex-proof fuses typeXFU…

Ex-proof fuses typeXFU…
Type of protection:
I M2 Ex ema I IP20  II 2GD Ex ema tD II IP20
Service temperature: -60°C do +84°C
Nominal voltage: 110 V DC, 250 V AC
Conductor cross-section:: 2×0,35 mm2 do 2×2,5 mm2
Dimensions (w × h × d): (40 × 23,5 × 41,5) mm
Order No.: XHU F 100 H
    Time delay:
FFvery quick breaking,
Fquick breaking,
Mnormal,
Tdelayed,
TT very delayed
Nominal current: 50; 63; 80; 100; 125; 160; 200; 350; 315; 400; 500; 630; 800 mА
1; 1,25; 1,6; 2; 2,5; 3,15; 4; 5; 6,3; 8; 10; 12,5; 16 A

Breaking capability (Ik):
H (1500A),
E (150A),
L(35A)

BEx-proof termination elements typeXZ..

BEx-proof termination elements typeXZ..
Type of protection:
I M2 / II 2GD  Ex emb tD I/II T6 IP 20
Service temperature: -55°C do +84°C
Nominal voltage, current, impedance R, capacitance C, diode type, etc. please see the Order No.
Conductor cross-section: 2×0,35 mm2 do 2×2,5 mm2
Dimensions (w × h × d): (40 × 23,5 × 42) mm
Order No.: XZ R 680
    Type of termination element:
D(diode),
R(resistor),
RC(resistor and capacitor),
V(varistor
Value of the termination element: e.g. 680 Ω, 4k7, … resistor value (for Relement); 400 V, … Nominal voltage
(for Varistor and RCelement); 1 Anominal current (for Diode

EX COMPONENTS – POTENTIOMETERS

Ex-proof potentiometer typeX195RP


Ex-proof potentiometer typeX195RP
Type of protection:
I M2 Ex d I
Service temperature: -60°C +85°C
Load: 1W
Max. collector current: 100 mA
Max. nominal voltage: 250 V AC/DC
Impedance characteristics: liniowy
Nominal impedance: 47R -2M2
Values available: 1K, 2K, 5K, 10K
Shaft diameter: Ø6 mm
Connection: 3 wyprowadzone przewody0,35 mm2, każdy o standardowej długości 30 cm