Doppel Thyristor-Leistungsblöcke M2C
  • Doppel Thyristor-Leistungsblöcke M2C

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: DACPOL

Doppel Thyristor-Leistungsblöcke M2C

Two element power diode block with radiator RY.

Properties:
• Two element power diode block with both side cooling– RY
• Natural cooling


Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts

Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling

Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.

Scheme


Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature -100 C - +400 C;
• Atmospheric pressure 860hPa do 1060hPa;
• Humidity less then 80% @ temperature 400 C
• Cooling air without aggressive factors.

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight
[kg]
M2C7P 450…650 400…2400 7000…10000 6,9
M2C8P 630…1000 400…8500 10000…24000 6,9
M2C9P 1000…2000 400…7500 20000…42000 16,4
M2C11P 1000…3200 400…6000 27000…65000 18,30

 
Power block scheme M2C...P
 

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Two element power diode block with radiator RY.

Properties:
• Two element power diode block with both side cooling– RY
• Natural cooling


Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts

Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling

Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.

Scheme


Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature -100 C - +400 C;
• Atmospheric pressure 860hPa do 1060hPa;
• Humidity less then 80% @ temperature 400 C
• Cooling air without aggressive factors.

 

Table 1 Power blocks parameters
 

Module type Mean current IF(AV) [A] Blocking voltage  U RRM
    [V]
Overcurrent
I FSM
[A]
Semiconductor size
[mm]
Block Weight
[kg]
M2C7P 450…650 400…2400 7000…10000 6,9
M2C8P 630…1000 400…8500 10000…24000 6,9
M2C9P 1000…2000 400…7500 20000…42000 16,4
M2C11P 1000…3200 400…6000 27000…65000 18,30

 
Power block scheme M2C...P