Sie müssen eingeloggt sein
-
zurückX
-
Alle Kategorien
-
-
Category
-
Halbleiter
- Dioden
- Thyristoren
-
Elektroisolierte Module
- Elektroisolierte Module | VISHAY (IR)
- Elektroisolierte Module | INFINEON (EUPEC)
- Elektroisolierte Module | Semikron
- Elektroisolierte Module | POWEREX
- Elektroisolierte Module IXYS
- Elektroisolierte Module | POSEICO
- Elektroisolierte Module ABB
- Elektroisolierte Module | TECHSEM
- Gehen Sie zur Unterkategorie
- Brückengleichrichter
-
Transistoren
- Transistoren | GeneSiC
- SiC-MOSFET-Module | Mitsubishi
- SiC-MOSFET-Module | STARPOWER
- ABB SiC-MOSFET-Module
- IGBT-Module | MITSUBISHI
- Transistormodule | MITSUBISHI
- MOSFET-Module von MITSUBISHI
- Transistormodule | ABB
- IGBT-Module | POWEREX
- IGBT-Module | INFINEON (EUPEC)
- Halbleiterkomponente aus Siziliumkarbid
- Gehen Sie zur Unterkategorie
- Treiber
- Leistungsblöcke
- Gehen Sie zur Unterkategorie
-
Strom- und Spannungswandler von LEM
-
Stromwandler von LEM
- Stromwandler mit geschlossener Rückkopplungsschleife (C / L)
- Stromwandler mit offener Rückkopplungsschleife (O / L)
- Stromwandler mit unipolarer Spannung
- Wandler in der Eta-Technologie
- Hochgenaue Stromwandler der Serie LF xx10
- Stromwandler der Serie LH
- HOYS und HOYL - zur direkten Montage auf einer Leiterschiene
- Stromwandler in der SMD-Technologie der Serien GO-SME und GO-SMS
- AUTOMOBIL-Stromwandler
- Gehen Sie zur Unterkategorie
- Spannungswandler | LEM
- Wandler zum Schutz, zur Überwachung und Steuerung | LEM
- Split-Core-Wandler | LEM
- Präzisionsstromwandler | LEM
- Gehen Sie zur Unterkategorie
-
Stromwandler von LEM
-
Passive Elemente (Kondensatoren, Widerstände, Sicherungen, Filter)
- Widerstände
-
Sicherungen
- Miniatursicherungen für elektronische Schaltungen der Serien ABC und AGC
- Schnelle Röhrensicherungen
- Zeitverzögerungssicherungen mit GL / GG- und AM-Eigenschaften
- Ultraschnelle Sicherungseinsätze
- Britische und amerikanische schnelle Sicherungen
- Schnelle europäische Sicherungen
- Traktionssicherungen
- Hochspannungs-Sicherungseinsätze
- Gehen Sie zur Unterkategorie
-
Kondensatoren
- Kondensatoren für Motoren
- Elektrolytkondensator
- Island Filmkondensatoren
- Leistungskondensatoren
- Kondensatoren für Gleichstromkreise
- Kondensatoren zur Leistungskompensation
- Hochspannungskondensatoren
- Induktionsheizkondensatoren
- Impulskondensatoren
- DC LINK-Kondensatoren
- Kondensatoren für AC / DC-Schaltungen
- Gehen Sie zur Unterkategorie
- Entstörungsfilter
- Superkondensatoren
-
Überspannungsschutz
- Überspannungsableiter für HF-Anwendungen
- Überspannungsableiter für Bildverarbeitungssysteme
- Überspannungsableiter für Stromleitungen
- Überspannungsableiter für LED
- Überspannungsableiter für die Photovoltaik
- Überspannungsableiter für Wägesysteme
- Überspannungsableiter für den Feldbus
- Gehen Sie zur Unterkategorie
- Gehen Sie zur Unterkategorie
-
Relais und Schütze
- Theorie der Relais und Schütze
- Dreiphasen-Halbleiterrelais AC
- Halbleiterrelais DC
- Regler, Steuerungen und Zubehör
- Sanftstarter und Schaltschütze
- Elektromechanische Relais
- Schütze
- Drehschalter
-
Einphasen-Halbleiterrelais AC
- Einphasen-Wechselstrom-Halbleiterrelais, Serie 1 | D2425 | D2450
- Einphasige AC-Halbleiterrelais der Serien CWA und CWD
- Einphasen-Wechselstrom-Halbleiterrelais der Serien CMRA und CMRD
- Einphasen-Wechselstrom-Halbleiterrelais, PS-Serie
- Doppel- und Vierfach-Wechselstrom-Halbleiterrelais, Serie D24 D, TD24 Q, H12D48 D.
- 1-phasige Festkörperrelais, gn-Serie
- Einphasige Wechselstrom-Halbleiterrelais, Serie ckr
- Einphasen-Wechselstromrelais der ERDA- UND ERAA-SERIE für die DIN-Schiene
- Einphasige Wechselstromrelais für 150A Strom
- Doppelte Halbleiterrelais mit integriertem Kühlkörper für eine DIN-Schiene
- Gehen Sie zur Unterkategorie
- Einphasen-Halbleiterrelais AC für Leiterplatten
- Interface-Relais
- Gehen Sie zur Unterkategorie
- Induktive Komponente
- Radiatoren, Varistoren, Thermoschütze
- Ventilatoren
- Klimaanlagen, Ausrüstung für Schaltschränke, Industriekühler
-
Batterien, Ladegeräte, Pufferstromversorgungen und Wechselrichter
- Batterien, Ladegeräte - theoretische Beschreibung
- Lithium-Ionen-Batterien. Kundenspezifische Batterien. Batteriemanagementsystem (BMS)
- Batterien
- Ladegeräte und Zubehör
- USV-Notstromversorgung und Pufferstromversorgung
- Konverter und Zubehör für die Photovoltaik
- Energiespeicher
- Brennstoffzellen
- Lithium-Ionen-Batterien
- Gehen Sie zur Unterkategorie
-
Automation
- Grenzschalter, Microschalter
- Sensoren, Wandler
-
Pyrometer
- Infrarot-Temperatursensor, kabellos, wasserdicht, IR-TE-Serie
- Infrarot-Temperatursensor, kabellos, IR-TA-Serie
- Infrarot-Temperatursensor, kabellos, IR-H-Serie
- Ein schnelles stationäres Pyrometer in einem sehr kleinen IR-BA-Gehäuse
- Lichtleiter-Temperatursensoren, IR-FA-Serie
- Das stationäre Pyrometer der IR-BZ-Serie
- Gehen Sie zur Unterkategorie
- Zähler, Zeitrelais, Einbaumessgeräte
- Industrielle Schutzausrüstung
- Licht- und Signalentechnik
- Infrarot-Kamera
- LED-Anzeigen
- Taster, Schalter und Zubehör
-
Datenerfassung und Datenlogger
- Temperaturschreiber mit Display und Textdruck AL3000
- Digitale Temperaturschreiber mit LCD Display KR 2000-Serie
- Sicherheitstemperaturwächter KR 5000
- Temperatur / Feuchtigkeit Hand-Meter mit Datenlogger HN-CH-Serie
- Messdatenerfassung und Datenlogger Zubehör
- Kompakter Bildschirmschreiber 71VR1
- Sicherheitstemperaturwächter KR 3000-Serie
- PC-Datenerfassung R1M-Serie
- PC-Datenerfassung R2M-Serie
- PC-Datenerfassung, 12 universelle isolierte Eingänge, Typ RZMS-U9
- PC-Datenerfassung, 12 universelle isolierte Eingänge, USB, RZUS-Serie
- Gehen Sie zur Unterkategorie
- Steuerungen
- Gehen Sie zur Unterkategorie
-
Adern, Litzen, Schutzhüllen, Flexible Verbingungen
- Drähte
- Litzen
-
Kabel für spezielle Anwendungen
- Verlängerungskabel und Kompensations
- Kabel für Thermoelemente
- Die Verbindungsdrähte zu czyjnków PT
- Mehradrige Kabel Temp. -60 ° C bis + 1400 ° C
- SILICOUL Mittelspannungskabeln
- Zündkabel
- Heizleitungen
- Einadriges Temp. -60 ° C bis + 450 ° C
- Zugbegleiter
- Heizleitungen im Ex
- Gehen Sie zur Unterkategorie
- Schläuche
-
Geflochtene Kabel
- Zöpfe flach
- Zöpfen Runde
- Sehr flexible Geflecht - flach
- Sehr flexible Geflecht - Rund
- Kupfergeflecht zylindrischen
- Kupfergeflechtschirm und zylindrischer
- Flexible Massebänder
- Geflechte zylindrischen verzinkt und Edelstahl
- PVC-isolierte Kupferlitzen - Temperatur 85 ° C
- Flach geflochtene Aluminium
- Connection Kit - Zöpfe und Röhren
- Gehen Sie zur Unterkategorie
- Leitungen und Sonstiges für Traktion
- Crimpverbinder
- Flexible isolierte Kupferschienen
- Mehrschichte flexible Kupferschienen
- Kabelrohre, Kabelkanäle und Kabelführung
- Kabelschutzschlauchsysteme
- Gehen Sie zur Unterkategorie
- Alle Kategorien
-
Halbleiter
-
-
- Lieferanten
-
Applications
- AC- und DC-Antriebe (Wechselrichter)
- Ausrüstung für Verteilungs-, Steuerungs- und Telekommunikationsschränke
- Bergbau, Metallurgie und Gründung
- CNC-Werkzeugmaschinen
- HLK-Automatisierung
- Induktionsheizung
- Industrielle Automatisierung
- Industrielle Automatisierung
- Industrielle Schutzvorrichtungen
- Komponenten für explosionsgefährdete Bereiche (EX)
- Maschinen zum Tiefziehen von Kunststoffen
- Maschinen zum Trocknen und Verarbeiten von Holz
- Motoren und Transformatoren
- Schweißmaschinen und Schweißmaschinen
- Straßenbahn- und Bahntraktion
- Temperaturmessung und -regelung
- Temperaturmessung und -regelung
- USV- und Gleichrichtersysteme
-
SERVICE, REPARATUR
-
-
Installation der Ausrüstung
-
- Kontakt
- Zobacz wszystkie kategorie
Fotos dienen nur zu Informationszwecken.
please use latin characters
Notes on use
If condensed water formation is to be monitored in a room, the most humid position should first be established. The coldest position does not necessarily have to be the most humid position (see hx diagram). It should also be borne in mind that any changes in the room cannot result in a different, more humid spot. The FAS humidity add-on switch
must be mounted in such a way that there is good heat contact with the selected position. Please note also that any condensate must not get into the interior of the housing. Attachment is made by using the supplied
binders which can be used for pipes with diameters of up to 50mm.The housing must not be exposed to any outside heat as this may cause incorrect measurements.
The installation position is to be selected in such a way that a representative measurement of the air humidity will be given, i.e. the ambient air must be able to reach the measuring element within the casing without obstacles. The FAS should be exposed to the flow of air.
Maintenance
The measuring element is maintenance-free in pure ambient air. Aggressive media containing solvent can cause measuring errors and failure, depending on the type and concentration. As with almost all humidity measuring elements, deposits which eventually form a waterrepellent film over the sensor are harmful. Such substances are resin aerosols, lacquer aerosols, smoke deposits etc.
Description of the switch
The hygro module HM120 with „Polyga®“ measuring element is arranged on an aluminium base plate such that the measuring element is immediately next to the base plate. Protected by the housing, relative humidity near to dew point can form in the interior. The aluminium plate is adjacent to the cooling pipe and
transfers coldness to the measuring element. The measuring point can be adjusted in the interior. The
threshold value can be adapted accordingly to the local conditions. The microswitch of the HM120
switches a changeover contact potential-free. The standard switch is lined with silver contacts.
Optionally there is a microswitch with gold contact for low currents and voltages to a maximum of 100mA/48V AC and a minimum of 1mA/5V The FAS does not require a supply voltage.
Adjusting the switch point
It is important to set the correct switch point for the equipment. A set value that is too high can cause dew
to form as the conditions at the measuring point are not constant. Tests have shown that good results are
achieved at a switch point of 80 % rh. The switch point can be adapted to the equipment.
Open the covering cap and finely adjust the set value..
Technical Data: | ||
- scale range | 30...100 % rh | |
- measuring accuracy | ±3.0%rh | |
- range of operation | 50...100%rh | |
- Switching difference(microswitch)ref. to 50rh | approx. 4%rh | |
- voltage (recommended) | 24VAC | |
- max. voltage | (230VAC) | |
- breaking capacity, maximum load | ||
ohmic load | 2A 48VAC (10000 cykli) | |
inductive load* cos ϕ = 0.7 | 0.2A 230V AC | |
inductive load L/R=3ms | 1A for 50V DC | |
0.5A for 75V DC | ||
Electric bulb load | 0.2A for 50V DC | |
- breaking capacity, max | maks. 100mA, 48VAC | |
optional with golden contact | ||
- breaking capacity, max | maks. 100mA, 48VAC | |
min. 1mA, 5V | ||
- allowable ambient temperature | 0...60°C | |
- temperature coefficient | -0.2%/K rel. dla 20°C/ 50%rh | |
- half-time at v=2m/sec | 1.2min | |
- mounting position | optional | |
- contacting | connecting terminals | |
- electromagnetic compatibility EMC | ||
resistance to interference | zg. EN 50 082-2 | |
interference emission | zg. EN 50 081-2 | |
- type of protection | IP20 | |
- dimensions | 85x55x33mm | |
- weight | approx 70g |
Senden Sie eine Anfrage
Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Kontaktiere uns
Sie müssen eingeloggt sein
Notes on use
If condensed water formation is to be monitored in a room, the most humid position should first be established. The coldest position does not necessarily have to be the most humid position (see hx diagram). It should also be borne in mind that any changes in the room cannot result in a different, more humid spot. The FAS humidity add-on switch
must be mounted in such a way that there is good heat contact with the selected position. Please note also that any condensate must not get into the interior of the housing. Attachment is made by using the supplied
binders which can be used for pipes with diameters of up to 50mm.The housing must not be exposed to any outside heat as this may cause incorrect measurements.
The installation position is to be selected in such a way that a representative measurement of the air humidity will be given, i.e. the ambient air must be able to reach the measuring element within the casing without obstacles. The FAS should be exposed to the flow of air.
Maintenance
The measuring element is maintenance-free in pure ambient air. Aggressive media containing solvent can cause measuring errors and failure, depending on the type and concentration. As with almost all humidity measuring elements, deposits which eventually form a waterrepellent film over the sensor are harmful. Such substances are resin aerosols, lacquer aerosols, smoke deposits etc.
Description of the switch
The hygro module HM120 with „Polyga®“ measuring element is arranged on an aluminium base plate such that the measuring element is immediately next to the base plate. Protected by the housing, relative humidity near to dew point can form in the interior. The aluminium plate is adjacent to the cooling pipe and
transfers coldness to the measuring element. The measuring point can be adjusted in the interior. The
threshold value can be adapted accordingly to the local conditions. The microswitch of the HM120
switches a changeover contact potential-free. The standard switch is lined with silver contacts.
Optionally there is a microswitch with gold contact for low currents and voltages to a maximum of 100mA/48V AC and a minimum of 1mA/5V The FAS does not require a supply voltage.
Adjusting the switch point
It is important to set the correct switch point for the equipment. A set value that is too high can cause dew
to form as the conditions at the measuring point are not constant. Tests have shown that good results are
achieved at a switch point of 80 % rh. The switch point can be adapted to the equipment.
Open the covering cap and finely adjust the set value..
Technical Data: | ||
- scale range | 30...100 % rh | |
- measuring accuracy | ±3.0%rh | |
- range of operation | 50...100%rh | |
- Switching difference(microswitch)ref. to 50rh | approx. 4%rh | |
- voltage (recommended) | 24VAC | |
- max. voltage | (230VAC) | |
- breaking capacity, maximum load | ||
ohmic load | 2A 48VAC (10000 cykli) | |
inductive load* cos ϕ = 0.7 | 0.2A 230V AC | |
inductive load L/R=3ms | 1A for 50V DC | |
0.5A for 75V DC | ||
Electric bulb load | 0.2A for 50V DC | |
- breaking capacity, max | maks. 100mA, 48VAC | |
optional with golden contact | ||
- breaking capacity, max | maks. 100mA, 48VAC | |
min. 1mA, 5V | ||
- allowable ambient temperature | 0...60°C | |
- temperature coefficient | -0.2%/K rel. dla 20°C/ 50%rh | |
- half-time at v=2m/sec | 1.2min | |
- mounting position | optional | |
- contacting | connecting terminals | |
- electromagnetic compatibility EMC | ||
resistance to interference | zg. EN 50 082-2 | |
interference emission | zg. EN 50 081-2 | |
- type of protection | IP20 | |
- dimensions | 85x55x33mm | |
- weight | approx 70g |