Measures DC mA signals used in industrial automation equipment, PLC, transmitters, process control and analog I/0 systems without breaking the loop.
Kew 2500 is ideal for measuring the level of 4-20 mA signals correlating process indi-cation with real physical value.
Very useful to maintain and troubleshoot process and automation equipment without breaking the loop and stopping the process.
| DC A | 20/100mA(Auto ranging) ±0.2%rdg±5dgt(0.00mA~21.49mA) ±1.0%rdg±5dgt(21.0mA~120.0mA) |
|---|---|
| Conductor size | φ6mm max. |
| Analog output | Recorder: DC1000mV against DC100mA |
| Withstand voltage | 2210V AC for 5 seconds |
| Applicable standards | IEC 61010-1, 61010-2-030 CAT.Ⅱ 300V IEC 61010-2-032 IEC 61326-1, 61326-2-2 IEC 60529 IP40 |
| Operating temperature [&] humidity | -10~+50℃ < 85% |
| Storage temperature [&] humidity | -20~+60℃ < 85% |
| Power source | R6/LR6(AA) (1.5V) × 4 |
| Dimensions | 111(L) × 61(W) × 40(D)mm : Display unit 104(L) × 34(W) × 20(D)mm : Sensor 700mm : Sensor cable |
| Weight | Approx. 290g (including batteries) |
| Accessories | 9096(Carrying case) LR6(AA) × 4 Instruction manual, Calibration certificate |
| Optional | 7256(Output cord) |

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Sie müssen eingeloggt sein

Applications
Measures DC mA signals used in industrial automation equipment, PLC, transmitters, process control and analog I/0 systems without breaking the loop.
Kew 2500 is ideal for measuring the level of 4-20 mA signals correlating process indi-cation with real physical value.
Very useful to maintain and troubleshoot process and automation equipment without breaking the loop and stopping the process.
| DC A | 20/100mA(Auto ranging) ±0.2%rdg±5dgt(0.00mA~21.49mA) ±1.0%rdg±5dgt(21.0mA~120.0mA) |
|---|---|
| Conductor size | φ6mm max. |
| Analog output | Recorder: DC1000mV against DC100mA |
| Withstand voltage | 2210V AC for 5 seconds |
| Applicable standards | IEC 61010-1, 61010-2-030 CAT.Ⅱ 300V IEC 61010-2-032 IEC 61326-1, 61326-2-2 IEC 60529 IP40 |
| Operating temperature [&] humidity | -10~+50℃ < 85% |
| Storage temperature [&] humidity | -20~+60℃ < 85% |
| Power source | R6/LR6(AA) (1.5V) × 4 |
| Dimensions | 111(L) × 61(W) × 40(D)mm : Display unit 104(L) × 34(W) × 20(D)mm : Sensor 700mm : Sensor cable |
| Weight | Approx. 290g (including batteries) |
| Accessories | 9096(Carrying case) LR6(AA) × 4 Instruction manual, Calibration certificate |
| Optional | 7256(Output cord) |