Glühen von Edelstahl

Heat a stainless steel tube

Objective: To heat a stainless steel tube while avoiding oxidation for an annealing application; the end product is a handle for a dental tool.

Material: Steel tube, hydrogen gas, bell jar and fixture

Temperature: 1038 °C

Frequency: 270 kHz

Equipment: Ambrell EASYHEAT LI 4 kW, 150-400 kHz induction heating system equipped with a remote workhead containing two 1.5 μF capacitors for a total capacitance of 0.75 μF, single position three-turn helical induction heating coil.

Process: The stainless steel tube was placed inside the tube and connected to hydrogen. A bell jar was placed over the tube to trap the hydrogen gas. Hydrogen was allowed to flow into the bell jar for one minute. Power was then turned on and the part began to heat. The part achieved annealing temperature within five seconds. Power was turned off and the part was allowed to cool for one minute.

Results:

  • Speed: The part heated to required temperature in a matter of seconds
  • Repeatability: Induction offers the same result every time, which makes it ideal for a high volume process such as this one
  • Ambrell Lab Expertise: The client leveraged the lab to come up with the right induction solution based on their specifications; the client was outsourcing the process but thanks to a better solution that mitigates the oxidation issue they are willing to bring it in house
  • Increased Production Efficiency: The previous oxidation issue forced them to polish the handles which added a step in their manufacturing process

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Heat a stainless steel tube

Objective: To heat a stainless steel tube while avoiding oxidation for an annealing application; the end product is a handle for a dental tool.

Material: Steel tube, hydrogen gas, bell jar and fixture

Temperature: 1038 °C

Frequency: 270 kHz

Equipment: Ambrell EASYHEAT LI 4 kW, 150-400 kHz induction heating system equipped with a remote workhead containing two 1.5 μF capacitors for a total capacitance of 0.75 μF, single position three-turn helical induction heating coil.

Process: The stainless steel tube was placed inside the tube and connected to hydrogen. A bell jar was placed over the tube to trap the hydrogen gas. Hydrogen was allowed to flow into the bell jar for one minute. Power was then turned on and the part began to heat. The part achieved annealing temperature within five seconds. Power was turned off and the part was allowed to cool for one minute.

Results:

  • Speed: The part heated to required temperature in a matter of seconds
  • Repeatability: Induction offers the same result every time, which makes it ideal for a high volume process such as this one
  • Ambrell Lab Expertise: The client leveraged the lab to come up with the right induction solution based on their specifications; the client was outsourcing the process but thanks to a better solution that mitigates the oxidation issue they are willing to bring it in house
  • Increased Production Efficiency: The previous oxidation issue forced them to polish the handles which added a step in their manufacturing process