Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: Sisel

Universelle Regulatoren

Dimensions:
     EUC442: 48x48mm,
     EUC742: 72x72mm,
     EUC842: 48x96mm,
     EUC942: 96x96mm,
* Communication vai RS-485 ModBus protocol (Optional).
* Selectable 0-20mA or 4-20mA analog control output.
* Relay output can be programmable as second alarm or control output.
* AL1 relay output for first alarm out.
* Input offset feature.
* In the case of sensor failure relay state can be
selected.
periodical running or
* Parameter access protection on 3 levels.
* Programming by using keypad or Modbus.
* CE marked according to European Norms.
 
Technical data
Accuracy  
±0,2% (of full scale) 1 digit
- Measure range
 
Depends on regulator
 
Pt100
-200... 600°C
 
Pt100
-99,9... 300°C
 
Thermocouple J
0...600 C
 
Thermocouple K
0...1200°C
 
Thermocouple T
0...400°C
 
Thermocouple S
0...1600°C
 
Thermocouple R
0...1600°C 
  analog signal
0 - 20mA     -999 - 4000°C
  analog signal
4 - 20mA     -999 - 4000°C
- Wyjście
 
Relay : 250V AC, 2A
   
Selectable as 0-20mA, 4-20mA
   
Selectable as 0-20mA, 4-20mA
   
logic control output.
- AL1
 
Relay : 250V AC, 2A
- Display
 
4 red digits LED, measured value
   
4 yellow digits LbU, set value
-Keyboard  
microswitch
-Supply
 
230V AC +10%, -20%, 50/60HZ, 9-30VDC/7-24VAC± 10% SMPS,
   
 
Ambient/storage temperature
 
0 ... +50°C/-25... +70°C (with no icing)
- Dimensions
 
EUC442 48x48x87mm
   
EUC742 72x72x97mm
EUC842 48x96x87mm
   
EUC942 96x96x50mm
Wiring
 
2.5mm² screw-terminal connections
- Weight
 
EUC442 250g (after packing)
   
EUC742 395g (after packing)
   
EUC842 395g (after packing)
   
EUC942 410g (after packing)

marking
Order Code :: EUC
1 - Dimensions
442 .....48x48x87mm
742 .....72x72x97mm
842 .....48x96x87mm
942 .....96x96x50mm
2 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC/
                7-24V AC
3 - Supply Voltage
RS........RS-485 Modbus communication
None....Don’t support RS-485 Modbus communication

Type Power supply Output
EUC 442 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 442 -SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 742 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 742 - SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 842 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 842 - SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 942 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 942 - SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)


Dimensions






Terminals

EUC442-230 EUC442-SM

EUC742-230 EUC742-SM

EUC842-230 EUC842-SM

EUC942-230 EUC942-SM
 

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Dimensions:
     EUC442: 48x48mm,
     EUC742: 72x72mm,
     EUC842: 48x96mm,
     EUC942: 96x96mm,
* Communication vai RS-485 ModBus protocol (Optional).
* Selectable 0-20mA or 4-20mA analog control output.
* Relay output can be programmable as second alarm or control output.
* AL1 relay output for first alarm out.
* Input offset feature.
* In the case of sensor failure relay state can be
selected.
periodical running or
* Parameter access protection on 3 levels.
* Programming by using keypad or Modbus.
* CE marked according to European Norms.
 
Technical data
Accuracy  
±0,2% (of full scale) 1 digit
- Measure range
 
Depends on regulator
 
Pt100
-200... 600°C
 
Pt100
-99,9... 300°C
 
Thermocouple J
0...600 C
 
Thermocouple K
0...1200°C
 
Thermocouple T
0...400°C
 
Thermocouple S
0...1600°C
 
Thermocouple R
0...1600°C 
  analog signal
0 - 20mA     -999 - 4000°C
  analog signal
4 - 20mA     -999 - 4000°C
- Wyjście
 
Relay : 250V AC, 2A
   
Selectable as 0-20mA, 4-20mA
   
Selectable as 0-20mA, 4-20mA
   
logic control output.
- AL1
 
Relay : 250V AC, 2A
- Display
 
4 red digits LED, measured value
   
4 yellow digits LbU, set value
-Keyboard  
microswitch
-Supply
 
230V AC +10%, -20%, 50/60HZ, 9-30VDC/7-24VAC± 10% SMPS,
   
 
Ambient/storage temperature
 
0 ... +50°C/-25... +70°C (with no icing)
- Dimensions
 
EUC442 48x48x87mm
   
EUC742 72x72x97mm
EUC842 48x96x87mm
   
EUC942 96x96x50mm
Wiring
 
2.5mm² screw-terminal connections
- Weight
 
EUC442 250g (after packing)
   
EUC742 395g (after packing)
   
EUC842 395g (after packing)
   
EUC942 410g (after packing)

marking
Order Code :: EUC
1 - Dimensions
442 .....48x48x87mm
742 .....72x72x97mm
842 .....48x96x87mm
942 .....96x96x50mm
2 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC/
                7-24V AC
3 - Supply Voltage
RS........RS-485 Modbus communication
None....Don’t support RS-485 Modbus communication

Type Power supply Output
EUC 442 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 442 -SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 742 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 742 - SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 842 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 842 - SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 942 230VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)
EUC 942 - SM 9-30VDC/7-24VAC 2 relays, SSR, 0...20ma, 4...20mA, RS485(optional)


Dimensions






Terminals

EUC442-230 EUC442-SM

EUC742-230 EUC742-SM

EUC842-230 EUC842-SM

EUC942-230 EUC942-SM