Aktuelle Transformatoren für Schaltgeräte - SAV150
  • Aktuelle Transformatoren für Schaltgeräte - SAV150

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: ELEQ

Aktuelle Transformatoren für Schaltgeräte - SAV150

The SVA150 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring
transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.


Environmental conditionss
This product is designed to be safe under the following conditions:
Location Indoor use
Ambient temperature: -5°C .. +40°C
Relative humidity: 5% .. 85%, non condensing
Protection degree: IP20
Suitable for: Cables, bus-bar
Application conditions
Standard: IEC 60044-1
Rated short-time thermal current (lth): 60 x In/1s
Continuous thermal current (lth): 100%
Rated insulation level: 0,72/3/-kv
Rated frequency: 50/60Hz
Class of insulation: E
Primary current 30-1000A
Primary window dimensions: Ø 60mm
Secondary terminal: Screw terminals (max. 2Nm)
Wire diameter max. 6mm² solid max 4mm² stranded


 

Radio Class Burden Atricle number
600-250/1/1 0.2/10P10 5VA 106530
400-150/1/1 0.2/5P10 5VA 106531

Wiring diagram

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns

FRAGEN SIE NACH DEM PRODUKT close
Nachricht erfolgreich gesendet.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

The SVA150 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring
transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.


Environmental conditionss
This product is designed to be safe under the following conditions:
Location Indoor use
Ambient temperature: -5°C .. +40°C
Relative humidity: 5% .. 85%, non condensing
Protection degree: IP20
Suitable for: Cables, bus-bar
Application conditions
Standard: IEC 60044-1
Rated short-time thermal current (lth): 60 x In/1s
Continuous thermal current (lth): 100%
Rated insulation level: 0,72/3/-kv
Rated frequency: 50/60Hz
Class of insulation: E
Primary current 30-1000A
Primary window dimensions: Ø 60mm
Secondary terminal: Screw terminals (max. 2Nm)
Wire diameter max. 6mm² solid max 4mm² stranded


 

Radio Class Burden Atricle number
600-250/1/1 0.2/10P10 5VA 106530
400-150/1/1 0.2/5P10 5VA 106531

Wiring diagram