Multifunction network analyzers with miniature split-core CTs
  • Multifunction network analyzers with miniature split-core CTs
  • Multifunction network analyzers with miniature split-core CTs
  • Multifunction network analyzers with miniature split-core CTs

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

Multifunction network analyzers with miniature split-core CTs

The multifunction network analyzer is supplied with 3 Rogowski coils.


It is suitable for use in three-phase three and four-wire systems, even with unbalanced loads and distorted waveforms. It does not require the use of external integrators. It allows you to get all the major measurements, including both power and energy produced and consumed. The connection is simplified with RJ45 connectors. The system is suitable for retrofitting to existing installations and for laboratory use, but also an excellent solution for monitoring electrical networks in new installations.



Technical data

Display Backlit LCD
Digits height 13.5mm
Max. indication 4 digits
Decimal point position Automatic
Adjustable backlight 5 levels
Readings update <0.5s
Frequency 50-60Hz
Measuring type True RMS
Set basic accuracy ±0.2%
Nominal input voltage Un 100V …400V
Input range 10-120% UN, 10-120% IN
VT ratio (max primary) 1MV
Continuos overload 2 x IN, 1.2 x UN
Short - term oveload 20 x IN, 2 x UN (300msec.)
Voltage circuits consumption <0.5VA
Energy counting kWh – kVArh - kVAh
Maximum counting 2 000 000 000
Operating temperature 0…23…50°C
Storage temperature -30…70°C
Supply voltage 80-260V ac/dc 3VA/2W
Thermoplastic material UL 94-V0
Protection for housing IP50
Protection for terminals IP20
Galvanic insulation Power supply/I/O


Current transformer - technical data

Thermoplastic materials UL94-V0
Frequency 50Hz
Insulation reference voltage 3 kV x 1’ 50 Hz
Test voltage 720V
Protection degree IP20
Continuous overlcurrent 1,2 x In
Operating temperature -20 +70 °C
Storage temperature -40 +80 °C


Measured variables

  • Line current
  • Star voltage L-N
  • Delta voltage L-L
  • V and I unbalance
  • Neutral current
  • Active power
  • Reactwive power
  • Apparent power
  • Power factor
  • Displacement power factor
  • Frequency
  • Thermal current
  • Maximum thermal current
  • Average power
  • Maximum demand (kw)
  • THD V and I up to 32th harm


Feature list

  • Snap-on closure system without screws
  • Fitted with a blade fuse for secondary short circuit protection
  • Fitted with a !xing system for DIN rail
  • Fixing system for CT mounting on primary cable
  • Integrated secondary cables
  • Easy installation in small spaces
  • Lightweight and small dimensions

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

The multifunction network analyzer is supplied with 3 Rogowski coils.


It is suitable for use in three-phase three and four-wire systems, even with unbalanced loads and distorted waveforms. It does not require the use of external integrators. It allows you to get all the major measurements, including both power and energy produced and consumed. The connection is simplified with RJ45 connectors. The system is suitable for retrofitting to existing installations and for laboratory use, but also an excellent solution for monitoring electrical networks in new installations.



Technical data

Display Backlit LCD
Digits height 13.5mm
Max. indication 4 digits
Decimal point position Automatic
Adjustable backlight 5 levels
Readings update <0.5s
Frequency 50-60Hz
Measuring type True RMS
Set basic accuracy ±0.2%
Nominal input voltage Un 100V …400V
Input range 10-120% UN, 10-120% IN
VT ratio (max primary) 1MV
Continuos overload 2 x IN, 1.2 x UN
Short - term oveload 20 x IN, 2 x UN (300msec.)
Voltage circuits consumption <0.5VA
Energy counting kWh – kVArh - kVAh
Maximum counting 2 000 000 000
Operating temperature 0…23…50°C
Storage temperature -30…70°C
Supply voltage 80-260V ac/dc 3VA/2W
Thermoplastic material UL 94-V0
Protection for housing IP50
Protection for terminals IP20
Galvanic insulation Power supply/I/O


Current transformer - technical data

Thermoplastic materials UL94-V0
Frequency 50Hz
Insulation reference voltage 3 kV x 1’ 50 Hz
Test voltage 720V
Protection degree IP20
Continuous overlcurrent 1,2 x In
Operating temperature -20 +70 °C
Storage temperature -40 +80 °C


Measured variables

  • Line current
  • Star voltage L-N
  • Delta voltage L-L
  • V and I unbalance
  • Neutral current
  • Active power
  • Reactwive power
  • Apparent power
  • Power factor
  • Displacement power factor
  • Frequency
  • Thermal current
  • Maximum thermal current
  • Average power
  • Maximum demand (kw)
  • THD V and I up to 32th harm


Feature list

  • Snap-on closure system without screws
  • Fitted with a blade fuse for secondary short circuit protection
  • Fitted with a !xing system for DIN rail
  • Fixing system for CT mounting on primary cable
  • Integrated secondary cables
  • Easy installation in small spaces
  • Lightweight and small dimensions