Easiest resistance sensor used for very precise temperature measurement of any environment. The only limit is:
- Temperature range, depends on connection cable insulation. (PCV – up to +120°C, teflon – up to +150°C, silicon – up to +180°C, fibre glass – 400°C).
 
SPECIFICATION

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type Time constant
T0,5
1xPt100
2xPt100
normal shockproof according to PN-EN-60751 od -50°C
do +250°C
B 8 mA 2 cables ≤ 5s
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA

Connection cable
Diameter Średnica Type Skład Operation temperature Cable length LK
2-cables Ø2.9 L2GGD-2xO,22mm2 fibre glass +400°C arbitrary
3, 4 cables  Ø3.1 L4GGD-4xO,22mm2 fibre glass +400°C
2-cables Ø4.2 L2TS-3x0,34mm2 teflon, silicon +180°C
3, 4 cables Ø4.3 L4TTS-4xO,25mm2 teflon, silicon +180°C

 

Marking:
A. Resistor type
A
 
Single
1xPt100
 
Double
2xPt100
B. Accuracy class
B
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
C. Connection and cable type
C
 
2 – cables L2GGD
2p-L2GGD
 
3 – cables L4GGD
3p-L4GGD
 
4 – cables L4GGD
4p-L4GGD
 
2 – cables L2TS
2p-L2TS
 
3 – cables L4TS
3p-L4TS
 
4 – cables L4TS
4p-L4TS
D. Resistor dimensions
D
 
d x L
give in mm
E. Cable length
F
 
LK
give in mm
F. Sensor type
H
 
normal
Z
 
shockproof
W

Caution
There are Non-standard models.
.

 

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Easiest resistance sensor used for very precise temperature measurement of any environment. The only limit is:
- Temperature range, depends on connection cable insulation. (PCV – up to +120°C, teflon – up to +150°C, silicon – up to +180°C, fibre glass – 400°C).
 
SPECIFICATION

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type Time constant
T0,5
1xPt100
2xPt100
normal shockproof according to PN-EN-60751 od -50°C
do +250°C
B 8 mA 2 cables ≤ 5s
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA

Connection cable
Diameter Średnica Type Skład Operation temperature Cable length LK
2-cables Ø2.9 L2GGD-2xO,22mm2 fibre glass +400°C arbitrary
3, 4 cables  Ø3.1 L4GGD-4xO,22mm2 fibre glass +400°C
2-cables Ø4.2 L2TS-3x0,34mm2 teflon, silicon +180°C
3, 4 cables Ø4.3 L4TTS-4xO,25mm2 teflon, silicon +180°C

 

Marking:
A. Resistor type
A
 
Single
1xPt100
 
Double
2xPt100
B. Accuracy class
B
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
C. Connection and cable type
C
 
2 – cables L2GGD
2p-L2GGD
 
3 – cables L4GGD
3p-L4GGD
 
4 – cables L4GGD
4p-L4GGD
 
2 – cables L2TS
2p-L2TS
 
3 – cables L4TS
3p-L4TS
 
4 – cables L4TS
4p-L4TS
D. Resistor dimensions
D
 
d x L
give in mm
E. Cable length
F
 
LK
give in mm
F. Sensor type
H
 
normal
Z
 
shockproof
W

Caution
There are Non-standard models.
.