Programmable transducers P5320 with HART communication and galvanic insulation
  • Programmable transducers P5320 with HART communication and galvanic insulation

Photos are for informational purposes only. View product specification

please use latin characters

Programmable transducers P5320 with HART communication and galvanic insulation

Universal input with wire input measurement range (2,5...25000 Ohm, -200...2200 mV).

Accuracy up to 0,05%  High electric withstand of galvanic insulation (4kV). Universal input for one or two sensors. Function for signal proccess from two sensors(difference, average, record). Function THERMO-VOLTAGE SUPPRESSION for thermo voltage elimination. Function BREAK-PREVENTION for thermo cell breaking protection.

Technical data

Supply voltage 9 - 35 VDC
Operation ambient temperatures: -40 - 85C°C
Reference temperature 23 ± 5 °C
Protection level: execution H1x IP40,  clamps IP00,after installation in head - head protection level
  execution L1x IP40, clamps IP20
Humidity execution H1 x 0 -100% with condensation after installation in head
  execution L1 x 0 -95% relative humidity without condensation
Cable connection: screw clamps for section 0,5 - 1,5mm2, screw torque 0,5 Nm.
Heating time: 10s
Bus type DIN: TS 35 according to DIN 46277
Dimensions (H.xW.xL.) H1 44 x 23,5 mm L1 x 90 x 18 x 59 mm (see dimensions drawings)
Casing material: H1x polycarbonate
  L1x polycarbonate
Weight: H1x40gL1x80g
Operation position: arbitrary

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Universal input with wire input measurement range (2,5...25000 Ohm, -200...2200 mV).

Accuracy up to 0,05%  High electric withstand of galvanic insulation (4kV). Universal input for one or two sensors. Function for signal proccess from two sensors(difference, average, record). Function THERMO-VOLTAGE SUPPRESSION for thermo voltage elimination. Function BREAK-PREVENTION for thermo cell breaking protection.

Technical data

Supply voltage 9 - 35 VDC
Operation ambient temperatures: -40 - 85C°C
Reference temperature 23 ± 5 °C
Protection level: execution H1x IP40,  clamps IP00,after installation in head - head protection level
  execution L1x IP40, clamps IP20
Humidity execution H1 x 0 -100% with condensation after installation in head
  execution L1 x 0 -95% relative humidity without condensation
Cable connection: screw clamps for section 0,5 - 1,5mm2, screw torque 0,5 Nm.
Heating time: 10s
Bus type DIN: TS 35 according to DIN 46277
Dimensions (H.xW.xL.) H1 44 x 23,5 mm L1 x 90 x 18 x 59 mm (see dimensions drawings)
Casing material: H1x polycarbonate
  L1x polycarbonate
Weight: H1x40gL1x80g
Operation position: arbitrary