Programmable transducers P5320 with HART communication and galvanic insulation
  • Programmable transducers P5320 with HART communication and galvanic insulation

Photos are for informational purposes only. View product specification

Programmable transducers P5320 with HART communication and galvanic insulation

Programmable transducers P5320 with HART communication and galvanic insulation

 

Universal input with wire input measurement range (2,5...25000 Ohm, -200...2200 mV). Accuracy up to 0,05%  High electric withstand of galvanic insulation (4kV). Universal input for one or two sensors. Function for signal proccess from two sensors(difference, average, record). Function THERMO-VOLTAGE SUPPRESSION for thermo voltage elimination. Function BREAK-PREVENTION for thermo cell breaking protection.
 
Technical data:
   
• Supply voltage 9 - 35 VDC
• Operation ambient temperatures: -40 - 85C°C
• Reference temperature 23 ± 5 °C
• Protection level:  
  execution H1x IP40,  clamps IP00,after installation in head - head protection level
  execution L1x IP40, clamps IP20
• Humidity  
  execution H1 x 0 -100% with condensation after installation in head
  execution L1 x 0 -95% relative humidity without condensation
• Cable connection: screw clamps for section 0,5 - 1,5mm2, screw torque 0,5 Nm.
• Heating time: 10s
• Bus type DIN: TS 35 according to DIN 46277
• Dimensions (H.xW.xL.) H1 44 x 23,5 mm L1 x 90 x 18 x 59 mm (see dimensions drawings)
• Casing material:  
  H1x polycarbonate
  L1x polycarbonate
• Weight: H1x40gL1x80g
• Operation position: arbitrary

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Programmable transducers P5320 with HART communication and galvanic insulation

 

Universal input with wire input measurement range (2,5...25000 Ohm, -200...2200 mV). Accuracy up to 0,05%  High electric withstand of galvanic insulation (4kV). Universal input for one or two sensors. Function for signal proccess from two sensors(difference, average, record). Function THERMO-VOLTAGE SUPPRESSION for thermo voltage elimination. Function BREAK-PREVENTION for thermo cell breaking protection.
 
Technical data:
   
• Supply voltage 9 - 35 VDC
• Operation ambient temperatures: -40 - 85C°C
• Reference temperature 23 ± 5 °C
• Protection level:  
  execution H1x IP40,  clamps IP00,after installation in head - head protection level
  execution L1x IP40, clamps IP20
• Humidity  
  execution H1 x 0 -100% with condensation after installation in head
  execution L1 x 0 -95% relative humidity without condensation
• Cable connection: screw clamps for section 0,5 - 1,5mm2, screw torque 0,5 Nm.
• Heating time: 10s
• Bus type DIN: TS 35 according to DIN 46277
• Dimensions (H.xW.xL.) H1 44 x 23,5 mm L1 x 90 x 18 x 59 mm (see dimensions drawings)
• Casing material:  
  H1x polycarbonate
  L1x polycarbonate
• Weight: H1x40gL1x80g
• Operation position: arbitrary