Silicable® RW EN 50382-2 3600V F 120 ° C
Silicable® RW EN 50382-2 3600V F 120 ° C
Silicable® RW EN 50382-2 3600V F 120 ° C

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: OMERIN

Silicable® RW EN 50382-2 3600V F 120 ° C

SILICABLE® RW EN 50382-2 3600V F 120 °C

Thermal

  • Continuous operating temperature: -40 °C to +120 °C (150 °C permissible for CuSn).

Electrical

  • Operating voltage: 3.6 / 6 kV.
  • Test voltage: 11 kV A.C.

Mechanical

  • Minimum static internal bending radius (EN 50355): 3xD.

Standards and Approvals

  • EN 60228, EN 50382-1, EN 50382-2.
  • EN 60754-1, EN 60754-2.
  • EN 60332-1-2, EN 60332-3-24, EN 61034-2.
  • EN 45545-2, NFPA 130.

Fire Protection

  • Halogen-free (EN 60754-1).
  • Low toxicity (EN 60754-2).
  • Low smoke emission (EN 61034-2).
  • Flame retardant (EN 60332-1-2, EN 60332-3-24).
  • Fire protection (EN 45545-2, NFPA 130).

Marking

OMERIN 369- EN 50382-2 3600V 1x < cross-section > F 120 °C - Batch number - week/year



Nominal core cross-section [mm2] Conductor construction
number of wires x Ø
Insulation thickness [mm] Outer diameter [mm] Max linear resistance at 20°C [Ω/km] Approx. weight [kg/km]
min max
2.5 50 x 0.25 3 7.6 8.9 8.21 80
4 56 x 0.30 3 8.1 9.5 5.09 100
6 84 x 0.30 3 9.0 10.6 3.39 130
10 80 x 0.40 3 9.5 1 1.1 1.95 180
16 126 x 0.40 3 10.5 12.3 1.24 250
25 196 x 0.40 3 1 1.8 13.8 0.795 350
35 276 x 0.40 3 13.0 15.2 0.565 450
50 396 x 0.40 3 14.4 16.9 0.393 600
70 360 x 0.50 3 16.1 18.9 0.277 800
95 485 x 0.50 3 17.5 20.5 0.210 1050
120 608 x 0.50 3.1 19.3 22.6 0.164 1300
150 756 x 0.50 3.1 20.8 24.4 0.132 1550
185 944 x 0.50 3.2 22.6 26.5 0.108 1950
240 1221 x 0.50 3.4 25.4 29.8 0.0817 2500
300 1525 x 0.50 3.4 27.7 32.4 0.0654 3050
400 2037 x 0.50 3.4 30.8 36.0 0.0495 3950

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

SILICABLE® RW EN 50382-2 3600V F 120 °C

Thermal

  • Continuous operating temperature: -40 °C to +120 °C (150 °C permissible for CuSn).

Electrical

  • Operating voltage: 3.6 / 6 kV.
  • Test voltage: 11 kV A.C.

Mechanical

  • Minimum static internal bending radius (EN 50355): 3xD.

Standards and Approvals

  • EN 60228, EN 50382-1, EN 50382-2.
  • EN 60754-1, EN 60754-2.
  • EN 60332-1-2, EN 60332-3-24, EN 61034-2.
  • EN 45545-2, NFPA 130.

Fire Protection

  • Halogen-free (EN 60754-1).
  • Low toxicity (EN 60754-2).
  • Low smoke emission (EN 61034-2).
  • Flame retardant (EN 60332-1-2, EN 60332-3-24).
  • Fire protection (EN 45545-2, NFPA 130).

Marking

OMERIN 369- EN 50382-2 3600V 1x < cross-section > F 120 °C - Batch number - week/year



Nominal core cross-section [mm2] Conductor construction
number of wires x Ø
Insulation thickness [mm] Outer diameter [mm] Max linear resistance at 20°C [Ω/km] Approx. weight [kg/km]
min max
2.5 50 x 0.25 3 7.6 8.9 8.21 80
4 56 x 0.30 3 8.1 9.5 5.09 100
6 84 x 0.30 3 9.0 10.6 3.39 130
10 80 x 0.40 3 9.5 1 1.1 1.95 180
16 126 x 0.40 3 10.5 12.3 1.24 250
25 196 x 0.40 3 1 1.8 13.8 0.795 350
35 276 x 0.40 3 13.0 15.2 0.565 450
50 396 x 0.40 3 14.4 16.9 0.393 600
70 360 x 0.50 3 16.1 18.9 0.277 800
95 485 x 0.50 3 17.5 20.5 0.210 1050
120 608 x 0.50 3.1 19.3 22.6 0.164 1300
150 756 x 0.50 3.1 20.8 24.4 0.132 1550
185 944 x 0.50 3.2 22.6 26.5 0.108 1950
240 1221 x 0.50 3.4 25.4 29.8 0.0817 2500
300 1525 x 0.50 3.4 27.7 32.4 0.0654 3050
400 2037 x 0.50 3.4 30.8 36.0 0.0495 3950