Category
Photos are for informational purposes only. View product specification
please use latin characters
Cable glands are used for electrical connections of devices in explosion hazardous areas. They are used to connect a flameproof enclosure with an enclosure of another protection type according to the DIN EN 60079-0 standard. It is also possible to connect two flameproof enclosures. Regardless of the application, the cables remain protected against direct contact with the hazardous atmosphere. Depending on the design, EX cable glands can be used in intrinsically safe applications, instrumentation, as well as control or power systems.
If the cable glands do not contain cables, they can be used as plugs for EX d type flameproof enclosures to seal holes and threads. In case of later expansion of the installation, it is possible to replace the plugs with standard cable entries.
Voltage | Up to 1kV |
---|---|
Cables | 0.07 mm2 to 95 mm2 |
Temperature Range | -55°C to 200°C |
Maximum Number of Cables | Up to 50 |
Threads | M10 to M42 |
Thread Length | > 10 mm |
Construction | Brass - nickel plated (others on request) |
Standard Cables | Radox 125 -50°C to 115°C Others on request |
Certification | ATEX II 2 G EX d IIC T4/T5/T6 Certification bodies: EPS08ATEX1105X IECEX, CSA, CSA_US, GOST |
If you additionally need to protect the cable, check our offer for heat shrink tubing, which fits the cable perfectly.
Are you interested in this product? Do you need additional information or individual pricing?
Cable glands are used for electrical connections of devices in explosion hazardous areas. They are used to connect a flameproof enclosure with an enclosure of another protection type according to the DIN EN 60079-0 standard. It is also possible to connect two flameproof enclosures. Regardless of the application, the cables remain protected against direct contact with the hazardous atmosphere. Depending on the design, EX cable glands can be used in intrinsically safe applications, instrumentation, as well as control or power systems.
If the cable glands do not contain cables, they can be used as plugs for EX d type flameproof enclosures to seal holes and threads. In case of later expansion of the installation, it is possible to replace the plugs with standard cable entries.
Voltage | Up to 1kV |
---|---|
Cables | 0.07 mm2 to 95 mm2 |
Temperature Range | -55°C to 200°C |
Maximum Number of Cables | Up to 50 |
Threads | M10 to M42 |
Thread Length | > 10 mm |
Construction | Brass - nickel plated (others on request) |
Standard Cables | Radox 125 -50°C to 115°C Others on request |
Certification | ATEX II 2 G EX d IIC T4/T5/T6 Certification bodies: EPS08ATEX1105X IECEX, CSA, CSA_US, GOST |
If you additionally need to protect the cable, check our offer for heat shrink tubing, which fits the cable perfectly.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent