Category
Photos are for informational purposes only. View product specification
please use latin characters
|
Characteristics • Continuous operating temperatures: -60 °C to +180 °C.• Good resistance to thermal shock and UV • Rated voltage: 300/500 V. • Test voltage: 2000 V. Standard products • All colors including two-colored.Approvals - standards • Halogen-free: IEC 60754-1 / EN 60754-1.• Low corrosivity of gas emissions: IEC 60754-2 / EN 60754-2. • Low smoke density: IEC 61034-2 / EN 61034-2. Applications • Cabling for household electrical heating appliances. Options • Outer electrical shielding: > Tin-plated copper braid: ref. RCSBE or RECSBE. |
![]() 1 • Solid bare copper (ref. RCS) or tin-plated (ref. RECS) core - class 1 as per IEC 60228. |
| Nominal cross-section [mm2] |
Nominal stranding | Maximum linear resistance at 20 °C [Ω/km] |
Nominal thickness of insulation [mm] |
Nominal diameter [mm] |
Approximate linear weight [kg/km] |
|---|---|---|---|---|---|
| 0.50 | 1 x 0.80 | 36.0 | 0.6 | 2.0 | 8.4 |
| 0.75 | 1 x 0.98 | 24.5 | 0.6 | 2,2 | 11.3 |
| 1 | 1 x 1.13 | 18.1 | 0.6 | 2.4 | 14.2 |
| 1.5 | 1 x 1.38 | 12.1 | 0.6 | 2.6 | 19.1 |
| 2.5 | 1 x 1.77 | 7.41 | 0.7 | 3,2 | 30.4 |
| 4* | 1 x 2.24 | 4.61 | 0.8 | 3.9 | 47.2 |
| 6* | 1 x 2.76 | 3.08 | 0.8 | 67.4 |
*Cross-sections are not available with ref. RECS.
Are you interested in this product? Do you need additional information or individual pricing?
|
Characteristics • Continuous operating temperatures: -60 °C to +180 °C.• Good resistance to thermal shock and UV • Rated voltage: 300/500 V. • Test voltage: 2000 V. Standard products • All colors including two-colored.Approvals - standards • Halogen-free: IEC 60754-1 / EN 60754-1.• Low corrosivity of gas emissions: IEC 60754-2 / EN 60754-2. • Low smoke density: IEC 61034-2 / EN 61034-2. Applications • Cabling for household electrical heating appliances. Options • Outer electrical shielding: > Tin-plated copper braid: ref. RCSBE or RECSBE. |
![]() 1 • Solid bare copper (ref. RCS) or tin-plated (ref. RECS) core - class 1 as per IEC 60228. |
| Nominal cross-section [mm2] |
Nominal stranding | Maximum linear resistance at 20 °C [Ω/km] |
Nominal thickness of insulation [mm] |
Nominal diameter [mm] |
Approximate linear weight [kg/km] |
|---|---|---|---|---|---|
| 0.50 | 1 x 0.80 | 36.0 | 0.6 | 2.0 | 8.4 |
| 0.75 | 1 x 0.98 | 24.5 | 0.6 | 2,2 | 11.3 |
| 1 | 1 x 1.13 | 18.1 | 0.6 | 2.4 | 14.2 |
| 1.5 | 1 x 1.38 | 12.1 | 0.6 | 2.6 | 19.1 |
| 2.5 | 1 x 1.77 | 7.41 | 0.7 | 3,2 | 30.4 |
| 4* | 1 x 2.24 | 4.61 | 0.8 | 3.9 | 47.2 |
| 6* | 1 x 2.76 | 3.08 | 0.8 | 67.4 |
*Cross-sections are not available with ref. RECS.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent