DC network surge arresters
Image | View the product | No. Manufacturer | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
picture_as_pdf |
![]() |
Acer Voltage | PSP 1/10/III - Surge arrester - 92001 | SEE IT | PSP 1/10/III | On Order | - 40°C ... + 55 °C | 83 mm | IP65 | 1,7 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 3,5 kV | 1,25 kV | 600/750 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 3/20/IV - Surge arrester - 92007 | SEE IT | PSP 3/20/IV | On Order | - 40°C ... + 55 °C | 117 mm | IP65 | 3,1 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 9,3 kV | 3,5 kV | custom |
picture_as_pdf |
![]() |
Acer Voltage | PSP 4,2/20/IV - Surge arrester - 92010 | SEE IT | PSP 4,2/20/IV | On Order | - 40°C ... + 55 °C | 130 mm | IP65 | 3,5 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 11,8 kV | 4,2 kV | 3000 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 4,7/20/IV - Surge arrester - 92008 | SEE IT | PSP 4,7/20/IV | On Order | - 40°C ... + 55 °C | 134 mm | IP65 | 3,65 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 12,4 kV | 4,7 kV | 3000 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 1/20/IV - Surge arrester - 94008 | SEE IT | PSPI 1/20/IV | On Order | - 40°C ... + 55 °C | 85 mm | IP62 | 1,9 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 3,1 kV | 1,2 kV | 600/750 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 1/20/IV SL - Surge arrester - 94008 SL | SEE IT | PSPI 1/20/IV SL | On Order | - 40°C ... + 55 °C | 85 mm | IP62 | 1,9 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 2,7 kV | 1 kV | 600 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 2/20/IV - Surge arrester - 94009 | SEE IT | PSPI 2/20/IV | On Order | - 40°C ... + 55 °C | 102 mm | IP62 | 2,3 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 6,2 kV | 2,35 kV | 1500 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 3/20/IV - Surge arrester - 94010 | SEE IT | PSPI 3/20/IV | On Order | - 40°C ... + 55 °C | 117 mm | IP62 | 2,9 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 9,3 kV | 3,5 kV | custom |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 4,2/20/IV - Surge arrester - 94013 | SEE IT | PSPI 4,2/20/IV | On Order | - 40°C ... + 55 °C | 130 mm | IP62 | 3,3 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 11,8 kV | 4,2 kV | 3000 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 4,7/20/IV - Surge arrester - 94011 | SEE IT | PSPI 4,7/20/IV | On Order | - 40°C ... + 55 °C | 134 mm | IP62 | 3,4 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 12,4 kV | 4,7 kV | 3000 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 2/20/IV - Surge arrester - 92006 | SEE IT | PSP 2/20/IV | On Order | - 40°C ... + 55 °C | 102 mm | IP65 | 2,5 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 6,2 kV | 2,35 kV | 1500 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 1/20/IV SL - Surge arrester - 92005SL | SEE IT | PSP 1/20/IV SL | On Order | - 40°C ... + 55 °C | 85 mm | IP65 | 2 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 2,7 kV | 1 kV | 600 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 1/20/IV - Surge arrester - 92005 | SEE IT | PSP 1/20/IV | On Order | - 40°C ... + 55 °C | 85 mm | IP65 | 2 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 3,1 kV | 1,2 kV | 600/750 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 2/10/III - Surge arrester - 92003 | SEE IT | PSP 2/10/III | On Order | - 40°C ... + 55 °C | 90 mm | IP65 | 1,9 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 7 kV | 2,5 kV | 1500 V |
picture_as_pdf |
![]() |
Acer Voltage | PSP 3/10/III - Surge arrester - 92004 | SEE IT | PSP 3/10/III | On Order | - 40°C ... + 55 °C | 102 mm | IP65 | 2,3 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 10,5 kV | 3,75 kV | custom |
picture_as_pdf |
![]() |
Acer Voltage | PSP 4/10/III - Surge arrester - 92002 | SEE IT | PSP 4/10/III | On Order | - 40°C ... + 55 °C | 110 mm | IP65 | 2,5 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 10,7 kV | 4,2 kV | 3000 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 1/10/III - Surge arrester - 94001 | SEE IT | PSPI 1/10/III | On Order | - 40°C ... + 55 °C | 83 mm | IP62 | 1,5 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 3,5 kV | -- | 600/750 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 2/10/III - Surge arrester - 94003 | SEE IT | PSPI 2/10/III | On Order | - 40°C ... + 55 °C | 88 mm | IP62 | 1,6 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 7 kV | 2,5 kV | 1500 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 3/10/III - Surge arrester - 94006 | SEE IT | PSPI 3/10/III | On Order | - 40°C ... + 55 °C | 106 mm | IP62 | 1,9 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 10,5 kV | 3,75 kV | custom |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 4/10/III - Surge arrester - 94002 | SEE IT | PSPI 4/10/III | On Order | - 40°C ... + 55 °C | 115 mm | IP62 | 2,1 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 10,7 kV | 4,2 kV | 3000 V |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 5/10/III - Surge arrester - 94004 | SEE IT | PSPI 5/10/III | On Order | - 40°C ... + 55 °C | 123 mm | IP62 | 2,3 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 14,2 kV | 5,5 kV | custom |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 6/10/III - Surge arrester - 94005 | SEE IT | PSPI 6/10/III | On Order | - 40°C ... + 55 °C | 125 mm | IP62 | 2,6 kg | 10 kA | 2 x 100 kA | 850 A | 3 | ≤ 17,7 kV | 6,7 kV | custom |
picture_as_pdf |
![]() |
Acer Voltage | PSPI 5/20/IV - Surge arrester - 94012 | SEE IT | PSPI 5/20/IV | On Order | - 40°C ... + 55 °C | 151 mm | IP62 | 4 kg | 20 kA | 2 x 100 kA | 1350 A | 4 | ≤ 15,5 kV | 5,85 kV | custom |
DC surge arresters are devices designed to protect DC-powered installations from the effects of lightning and switching overvoltages. They are an important element in securing systems using DC power, such as photovoltaic installations, uninterruptible power supply (UPS), and other DC networks.
Products in this subcategory protect devices from damage and interruptions that can occur as a result of sudden voltage surges or network disruptions. They can increase the reliability of the entire system and minimize the risk of failure of devices sensitive to surges.
Applications
DC surge arresters are used in:
-
photovoltaic installations – to protect solar panels, inverters, and other system components,
-
uninterruptible power supply systems (UPS),
-
overhead lines or other industrial installations using direct current,
-
wherever it is necessary to protect devices against surges in DC systems.
Advantages of use
-
increased safety and reliability installation,
-
reducing the risk of equipment damage and system downtime,
-
compatibility with various types of DC installations,
-
protection against the effects of atmospheric and switching overvoltages.