P5310 general purpose transducers programming with a LHP communication
  • P5310 general purpose transducers programming with a LHP communication

Photos are for informational purposes only. View product specification

please use latin characters

P5310 general purpose transducers programming with a LHP communication

Features

  • One type of transmitter for all common resistance and thermoelectric sensors
  • Unified current output signal 4 to 20 mA with a linearization
  • Accuracy from 0.1% for ranges down to 1/5 of the basic range
  • Span adjustability from 1% to 100% of the basic range
  • Galvanic isolation of input from output 1000 V AC (P5311)
  • Adjustable by program LHPWinConf and standard HART modem or by field configurator LHPConf (HARTConf)
  • Meet harsh industrial requirements and EMC standards according to EN 61326-1/A1
  • Intrinsically Safe Version (Ex) II 1GD

Technical data

Supply voltage 9...35 VDC
Operation temperature: -40...85°C
Ambient reference voltage: 23 ± 5oC
Degree level: execution H1x IP40, clamps IP00 after installation in head - head protection level
  execution L1x IP20
Humidity: execution H1x 0 - 100% with condensation after installation in head
  execution  L1x 10 - 80% humidity without condensation
Cable connection screw clamps for section: 0,5 - 1,5mm2, screw torque 0,5 Nm.
heating time after supply connection: 5s
Program time with PC: 5s
Type program with PC: 15s
Slat type DIN: TS 35 according to DIN 46277
Dimensions (H.xW.xL.) H1x 44x24 mm
  L1x 17,5x62,5x64 mm
Casing material H1x polycarbonate
  L1x polyamide
Weight: H1x,L1x40g
Operation position: arbitrary

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Features

  • One type of transmitter for all common resistance and thermoelectric sensors
  • Unified current output signal 4 to 20 mA with a linearization
  • Accuracy from 0.1% for ranges down to 1/5 of the basic range
  • Span adjustability from 1% to 100% of the basic range
  • Galvanic isolation of input from output 1000 V AC (P5311)
  • Adjustable by program LHPWinConf and standard HART modem or by field configurator LHPConf (HARTConf)
  • Meet harsh industrial requirements and EMC standards according to EN 61326-1/A1
  • Intrinsically Safe Version (Ex) II 1GD

Technical data

Supply voltage 9...35 VDC
Operation temperature: -40...85°C
Ambient reference voltage: 23 ± 5oC
Degree level: execution H1x IP40, clamps IP00 after installation in head - head protection level
  execution L1x IP20
Humidity: execution H1x 0 - 100% with condensation after installation in head
  execution  L1x 10 - 80% humidity without condensation
Cable connection screw clamps for section: 0,5 - 1,5mm2, screw torque 0,5 Nm.
heating time after supply connection: 5s
Program time with PC: 5s
Type program with PC: 15s
Slat type DIN: TS 35 according to DIN 46277
Dimensions (H.xW.xL.) H1x 44x24 mm
  L1x 17,5x62,5x64 mm
Casing material H1x polycarbonate
  L1x polyamide
Weight: H1x,L1x40g
Operation position: arbitrary