Category
Photos are for informational purposes only. View product specification
please use latin characters
• Type 2 surge protection for photovoltaics
• Discharge capacity per pole: In = 20kA;
I max = 40kA
• No impact on insulation measurement
• Replaceable module
• Remote signaling as standard
• Compliant with IEC 61643-11, EN 61643-11,
EN 50539-11, and UTE C 61-740-51 standards
Technical Data
| Description | DS50PVS-500 | |
|---|---|---|
| Rated voltage | UOCSTC | 500V DC |
| Protection method | CM/DM(2) | |
| Highest continuous operating voltage | UCPV | 530V DC |
| Short-circuit withstand strength | ISCWPV | 70A |
| Leakage current Voltage at Ucpv |
IPE | <1mA |
| Follow current | If | none |
| Follow current quenching capacity | Ifi | infinite |
| Tripping time | tA | <25 ns |
| Rated discharge current per pole (8/20 µs) |
In | 20kA |
| Max. discharge current (8/20 µs) | Imax | 40kA |
| Voltage protection level at In | Up | <1.8kV |
| Voltage protection level at 5kA | Up | <1.3kV |
| Disconnect Devices | |
|---|---|
| Thermal Disconnect | inside |
| Mechanical Properties | |
|---|---|
| Mounting Dimensions | 2 TE |
| Wire Cross-Section | 2.5-25 (35 mm²) |
| Fault Indicator | Mechanical, red |
| Remote Signaling (FS) | potential-free changeover contact |
| Max. switching power | 250V/0.5A (AC) - 30V/2A (DC) |
| Remote Signaling Wire Cross-Section | Max. 1.5 mm2 |
| Mounting method | TH35 mm mounting rail |
| Operating temperature range | -40 to +85°C |
| Housing protection rating | IP20 |
| Housing material | UL94-V0 thermoplastic |
| Control Standards | |
|---|---|
| PN-EN 61643-11 Poland | type 2 surge arrester |
| EN 50539-11 Europe | Low Voltage SPD - Class II Test |
| UL1449 ed.3 USA | Type 4, Type 2 Location Pending |
| Item number | 480111 |
| Replacement module | 3501003 |
Dimensions and diagram


V: High-power varistor block
Ft: Thermal protection
t°: Thermal disconnect device
C: Remote signaling contact
MI: Fault signaling
Are you interested in this product? Do you need additional information or individual pricing?
• Type 2 surge protection for photovoltaics
• Discharge capacity per pole: In = 20kA;
I max = 40kA
• No impact on insulation measurement
• Replaceable module
• Remote signaling as standard
• Compliant with IEC 61643-11, EN 61643-11,
EN 50539-11, and UTE C 61-740-51 standards
Technical Data
| Description | DS50PVS-500 | |
|---|---|---|
| Rated voltage | UOCSTC | 500V DC |
| Protection method | CM/DM(2) | |
| Highest continuous operating voltage | UCPV | 530V DC |
| Short-circuit withstand strength | ISCWPV | 70A |
| Leakage current Voltage at Ucpv |
IPE | <1mA |
| Follow current | If | none |
| Follow current quenching capacity | Ifi | infinite |
| Tripping time | tA | <25 ns |
| Rated discharge current per pole (8/20 µs) |
In | 20kA |
| Max. discharge current (8/20 µs) | Imax | 40kA |
| Voltage protection level at In | Up | <1.8kV |
| Voltage protection level at 5kA | Up | <1.3kV |
| Disconnect Devices | |
|---|---|
| Thermal Disconnect | inside |
| Mechanical Properties | |
|---|---|
| Mounting Dimensions | 2 TE |
| Wire Cross-Section | 2.5-25 (35 mm²) |
| Fault Indicator | Mechanical, red |
| Remote Signaling (FS) | potential-free changeover contact |
| Max. switching power | 250V/0.5A (AC) - 30V/2A (DC) |
| Remote Signaling Wire Cross-Section | Max. 1.5 mm2 |
| Mounting method | TH35 mm mounting rail |
| Operating temperature range | -40 to +85°C |
| Housing protection rating | IP20 |
| Housing material | UL94-V0 thermoplastic |
| Control Standards | |
|---|---|
| PN-EN 61643-11 Poland | type 2 surge arrester |
| EN 50539-11 Europe | Low Voltage SPD - Class II Test |
| UL1449 ed.3 USA | Type 4, Type 2 Location Pending |
| Item number | 480111 |
| Replacement module | 3501003 |
Dimensions and diagram


V: High-power varistor block
Ft: Thermal protection
t°: Thermal disconnect device
C: Remote signaling contact
MI: Fault signaling
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent